短路電流 的英文怎麼說

中文拼音 [duǎndiànliú]
短路電流 英文
isc
  • : Ⅰ形容詞(空間、時間兩端之間的距離小) short; brief Ⅱ動詞(缺少; 欠) lack; owe Ⅲ名詞1 (缺點) we...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • 短路 : [電學] short; short circuit; cutting out; direct short; short out; short pass短路保護(裝置) sho...
  • 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
  1. The increasing proportion of distributed generation ( dg ) in power system will deeply affect the distribution network structure, the amperage, direction, and distribution of short - circuit current in the existing distribution network, and will thus affect the operation and control of the distribution network

    摘要大量分散式發的並網運行將深刻影響現有配的結構、以及配網中短路電流的大小、向及分佈,由此給配網的運行與控制帶來多方面的影響。
  2. The two - point to earth short fault may cause short currents whic h can lead to serious accident. so it is necessary to monitor the state of field windings of turbo - generator and detect the kind of fault and predict its inclination. thus the security level of power system will be improved

    由於發機轉子兩點接地故障時會產生較大的短路電流,導致惡性事故的發生,因此對發機轉子繞組進行狀態監測,判斷故障的形式和趨勢是十分必要,有助於提高系統安全運行水平。
  3. The products is of high water hydrophobe device usedin suitable and has the characteristics of aging resistance, resistance, tracking resistance, and corrosive resistance. it can withstand high bent load, strong impact force fn12 - 12 series indoor use high voltage load switch fn12 - 12 and fn12 - 12r is of three phases indoor use ac high voltage load switch for breaking and making the circuit of 50hz, 12kv system under rated loading

    Fn12 - 12和fn12 - 12r組合器是額定壓12kv額定頻率50hz的三相高壓開關設備用於分合負荷閉環空載變壓器和纜充關合短路電流配裝接地開關的負荷開關,可以承受短路電流
  4. The influence of ph value of electrolyte on open circuit photovoltage and short circuit photocurrent is very significant

    解液的ph值對池的開壓和短路電流也有較大的影響。
  5. The development of a visual short circuit software under ptcad2000 is presented in this paper, as well as the system structure, the definition of the data structure, the interface to ptcad2000, the conversion of the original wiring diagram of power network to calculable power network, the implement of three sequence network, the implement of impendence matrix and admittance matrix of power network considering the zero sequence mutual inductances among lines, and the implement of short circuit calculation by using computer

    本文介紹了在ptcad2000平臺下短路電流可視化計算軟體的開發。介紹了軟體的系統結構、數據結構定義、與ptcad2000平臺的介面、力系統原始接線圖轉成等值可計算網、序網的生成、考慮零序互感線阻抗時網導納矩陣和阻抗矩陣的生成,以及故障點短路電流計算的計算機實現。
  6. The product vacuum arcing chamber adopts porcelain case, cup shape and longitudinal magnetic field contactor structure, copper and chrome contactor material, it has the capacity of good open and close short circuit current

    本產品真空滅弧室採用陶瓷外殼,杯狀縱磁場觸頭結構,銅鉻觸頭材料,具有優良的開斷和關合短路電流能力。
  7. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以纜為主的城區10kv網中性點接地方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際參數來建立數值計算模型,在考慮了網接地變化、中性點阻取值大小、接地點接地阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小阻接地方式下網的過壓水平和接地點短路電流大小進行了數值計算,其計算結果與科院所作現場試驗進行了比較。
  8. Its voltage, short circuit and resistance have not linear relation. and the temperature also affects its short circuit, when the temperature is higher, the short circuit is lower. when the battery is short joined directly, there is lots of heat in the battery to make the temperature be higher

    堿錳池是一種化學源,其復雜的化學性質使得其供壓、和內阻呈非線性關系,故而其短路電流值並不滿足歐姆定律,不僅和堿錳池的開壓、內阻有關系,還和池溫度有關系。
  9. Short - circuit current calculation in three - phase a. c. systems

    三相交系統短路電流計算
  10. Discussion on calculation method of three - phase short - circuit current

    三相短路電流計算方法的探討
  11. Transient short - circuit current

    瞬時短路電流
  12. Short - circuit currents. calculation of effects. examples of calculation

    短路電流.效應計算.計算範例
  13. Test of rated conditional short - circuit current of auxiliary contact

    輔助觸頭的額定限制短路電流試驗
  14. All electrical equipment has to be sized to withstand short - circuit current

    所有氣元件應能承受短路電流
  15. Short - circuit currents in three - phase a. c. systems - calculation of currents

    三相交系統內短路電流.的計算
  16. Short - circuit currents - calculation of effects - part 2 : examples of calculation

    短路電流效應的計算.第2部分:計算舉例
  17. Ananasis on the short - eircuit current of the infinitely great electric power system

    無限大容量力系統負載短路電流簡析
  18. Short - circuit currents in three - phase a. c. systems - part 0 : calculation of currents

    三相交系統短路電流.第0部分:計算
  19. Short - circuit currents - calculation of effects - definitions and calculation methods

    短路電流效應計算.第1部分:定義和計算方法
  20. ( 3 ) verifies the voltage wave, electrical current vuive and output power wave of asteroidal magneto, and the veracity of parameters by a series of experiments. the experimental result demonstrates that the error is less than 10 % between theoretic value and actual value

    ( 3 )通過一系列實驗驗證了星形磁機空載壓波形、波形、短路電流倍數、輸出功率等波形和參數的準確性,實驗結果表明,理論與實測值相差不到10 。
分享友人