短路電流 的英文怎麼說
中文拼音 [duǎnlùdiànliú]
短路電流
英文
isc- 短 : Ⅰ形容詞(空間、時間兩端之間的距離小) short; brief Ⅱ動詞(缺少; 欠) lack; owe Ⅲ名詞1 (缺點) we...
- 路 : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 流 : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
- 短路 : [電學] short; short circuit; cutting out; direct short; short out; short pass短路保護(裝置) sho...
- 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
-
The increasing proportion of distributed generation ( dg ) in power system will deeply affect the distribution network structure, the amperage, direction, and distribution of short - circuit current in the existing distribution network, and will thus affect the operation and control of the distribution network
摘要大量分散式發電的並網運行將深刻影響現有配電網路的結構、以及配電網中短路電流的大小、流向及分佈,由此給配電網的運行與控制帶來多方面的影響。The two - point to earth short fault may cause short currents whic h can lead to serious accident. so it is necessary to monitor the state of field windings of turbo - generator and detect the kind of fault and predict its inclination. thus the security level of power system will be improved
由於發電機轉子兩點接地故障時會產生較大的短路電流,導致惡性事故的發生,因此對發電機轉子繞組進行狀態監測,判斷短路故障的形式和趨勢是十分必要,有助於提高系統安全運行水平。The products is of high water hydrophobe device usedin suitable and has the characteristics of aging resistance, resistance, tracking resistance, and corrosive resistance. it can withstand high bent load, strong impact force fn12 - 12 series indoor use high voltage load switch fn12 - 12 and fn12 - 12r is of three phases indoor use ac high voltage load switch for breaking and making the circuit of 50hz, 12kv system under rated loading
Fn12 - 12和fn12 - 12r組合電器是額定電壓12kv額定頻率50hz的三相高壓開關設備用於分合負荷電流閉環電流空載變壓器和電纜充電電流關合短路電流配裝接地開關的負荷開關,可以承受短路電流The influence of ph value of electrolyte on open circuit photovoltage and short circuit photocurrent is very significant
電解液的ph值對電池的開路電壓和短路電流也有較大的影響。The development of a visual short circuit software under ptcad2000 is presented in this paper, as well as the system structure, the definition of the data structure, the interface to ptcad2000, the conversion of the original wiring diagram of power network to calculable power network, the implement of three sequence network, the implement of impendence matrix and admittance matrix of power network considering the zero sequence mutual inductances among lines, and the implement of short circuit calculation by using computer
本文介紹了在ptcad2000平臺下短路電流可視化計算軟體的開發。介紹了軟體的系統結構、數據結構定義、與ptcad2000平臺的介面、電力系統原始接線圖轉成等值可計算網路、序網的生成、考慮零序互感線路阻抗時電網導納矩陣和阻抗矩陣的生成,以及故障點短路電流計算的計算機實現。The product vacuum arcing chamber adopts porcelain case, cup shape and longitudinal magnetic field contactor structure, copper and chrome contactor material, it has the capacity of good open and close short circuit current
本產品真空滅弧室採用陶瓷外殼,杯狀縱磁場觸頭結構,銅鉻觸頭材料,具有優良的開斷和關合短路電流能力。The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance
爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。Its voltage, short circuit and resistance have not linear relation. and the temperature also affects its short circuit, when the temperature is higher, the short circuit is lower. when the battery is short joined directly, there is lots of heat in the battery to make the temperature be higher
堿錳電池是一種化學電源,其復雜的電化學性質使得其供電電壓、電流和內阻呈非線性關系,故而其短路電流值並不滿足歐姆定律,不僅和堿錳電池的開路電壓、內阻有關系,還和電池溫度有關系。Short - circuit current calculation in three - phase a. c. systems
三相交流系統短路電流計算Discussion on calculation method of three - phase short - circuit current
三相短路電流計算方法的探討Transient short - circuit current
瞬時短路電流Short - circuit currents. calculation of effects. examples of calculation
短路電流.效應計算.計算範例Test of rated conditional short - circuit current of auxiliary contact
輔助觸頭的額定限制短路電流試驗All electrical equipment has to be sized to withstand short - circuit current
所有電氣元件應能承受短路電流。Short - circuit currents in three - phase a. c. systems - calculation of currents
三相交流系統內短路電流.電流的計算Short - circuit currents - calculation of effects - part 2 : examples of calculation
短路電流效應的計算.第2部分:計算舉例Ananasis on the short - eircuit current of the infinitely great electric power system
無限大容量電力系統負載短路電流簡析Short - circuit currents in three - phase a. c. systems - part 0 : calculation of currents
三相交流系統短路電流.第0部分:電流計算Short - circuit currents - calculation of effects - definitions and calculation methods
短路電流效應計算.第1部分:定義和計算方法( 3 ) verifies the voltage wave, electrical current vuive and output power wave of asteroidal magneto, and the veracity of parameters by a series of experiments. the experimental result demonstrates that the error is less than 10 % between theoretic value and actual value
( 3 )通過一系列實驗驗證了星形磁電機空載電壓波形、電流波形、短路電流倍數、輸出功率等波形和參數的準確性,實驗結果表明,理論與實測值相差不到10 。分享友人