  1. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷器所造成的事故無論是在次數,還是在事故所造成的停時間上都占據總量60以上。因此,及時了解斷器的工作狀對提高供可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷器機械特性參數監測方法;提出了二次迴保護器的概念,並將跳、合閘線圈完整性監視和二次迴保護結合起來,給出具有完整性監視功能的二次迴保護器實現方案;根據斷器生產廠家提供的斷器額定分斷次數,計算每次分閘對應的觸頭壽命損耗,預測觸頭壽命;提出根據斷器殼體溫度和斷器周圍空氣溫度結合斷器熱阻來計算斷器主觸頭溫升的方法,並根據此時的負荷間接計算主觸頭迴阻;在硬體設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作壓晶元之間的介面問題,並給出了直接聯接的接線方案。
  2. The transient simulation model of impedance - matched balancing transformers is established. the effect of transient model and equivalent circuit in calculation of steady short circuit current are compared

    摘要建立了阻抗匹配平衡變壓器的暫模擬模型,比較了暫模型和等值在計算穩態短路電流中的效果。
  3. A non - linear feed - forward loop is used to realize the coordinated control between the two controlled variables at the two control ends at first. secondly, a constant ac voltage control is implemented for a short period after the ac fault removal. finally, a staggered recovery strategy for different hvdc subsystems is also adopted, with the restart time interval of them optimized using the steepest descent gradient search method

    該協調恢復策略的三個特點是:在常規的控制器結構中加入一個基於準工作點的非線性前饋迴;在交故障被切除后的一個暫時間內,逆變側採用定交壓控制:對不同的直子系統採取一種漸進的恢復策略。