節約冷量 的英文怎麼說

中文拼音 [jiéyāolěngliáng]
節約冷量 英文
conservation of refrigeration
  • : 節構詞成分。
  • : 約動詞[口語] (用秤稱) weigh
  • : Ⅰ形容詞1 (溫度低; 感覺溫度低) cold:冷水 coldwater; 你冷不冷? do you feel cold?; are you feeling...
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • 節約 : practice thrift; economize; save; economy
  1. After thermodynamic calculation on several operation conditions of the furnace, cold - state flow and resistance mensuration, the combustion of the tubular - furnace hearth was changed into swirl and addition of radiate cylinder and oxygen content detection minish 1. 25 surplus air to less than 1. 15, improving the combustion condition and convection and radiate heat transfer efficacy, resuling in reducing the waste - gas temperature 45, decreasing exhaust gas loss, and saving fuel by 6 %

    摘要通過對加熱爐幾種工況進行熱力計算、態試驗的流場分佈及阻力測定和熱態試驗的爐膛溫度場分佈及管壁溫度等參數的測定,確定將管式加熱爐爐膛內直流燃燒改為旋流場燃燒和增加輻射筒,增設煙氣含氧分析,可以將燃燒的過剩空氣系數從1 . 35減小到1 . 15以下,極好地改善爐膛內的燃燒狀況和對流輻射傳熱效果,從而降低排煙溫度45 ,減少加熱爐排煙損失,了煤氣6 %以上。
  2. In hot summer and cold winter zone, nearly 20 to 30 percent of total thermal loss in residential buildings is caused by the wall. therefore, energy - efficient design in the wall has become a basic research for architectural sustainable development

    在夏熱冬地區,外墻的耗熱占居住建築總熱損耗的20 30 ,因此,居住建築墻體能設計研究有著重要的現實意義。
  3. The problem of energy saving of water systems in the operating condition of part load is studied. the aim is to get a more reasonable control method. using this method, the supplied flux of chilled water can meet the needed flux of the building during the operating times of part load, the on / off condition of pumps and chiller can be decided reasonably and it has the advantage of saving energy in pumps and chiller

    本論文主要研究空調水系統在部分負荷下輸送的能問題,其目的在於尋求一種較合理的控制方法,使水機組和水泵在空調部分負荷下運行時,輸送的與實際建築物所需相匹配,以決定水泵和水機組的啟停,最大限度地水泵輸送能耗及水機組的製能耗。
  4. The main works and results we have accomplished are as follows : 1 ) red - detuned locking of cooling / trapping laser to the cycling transition of cesium cooling has been accomplished by means of a double - passed acoustic - optical frequency shifting system and the technique of saturated absorption spectroscopy. the short - term residual frequency jitter is less than 350khz ; 2 ) automatic controlling system by computer programs has been established for laser cooling and trapping and cavity qed experiment. the laser and magnetic fields can be controlled by the acoustic - optical modulator and the electronic - controlled logic gate respectively

    具體如下: 1 )採用了往返兩次通過的聲光頻移系統結合飽和吸收光譜技術的實驗方案,實現了卻俘獲激光頻率相對于銫原子卻循環躍遷的負失諧鎖定,短期頻率穩定度在350khz以內,並可方便地調其負失諧而無須對后續光路再作調整; 2 )建立了一套基於計算機程序控制的、銫原子激光卻與俘獲實驗所需的時序控制系統。
  5. The mathematical and physical dynamic models are given based on the adsorbent theory of porous medium. its running and parameters affecting its performance are numerically studied and the method that control the water content in the absorbent bed is recommended. the improvement on system configuration to recover heat is discussed and the operation scheme is given

    利用多孔介質吸附模型和平衡吸附壓力的概念建立了該系統工作過程的物理數學模型,數值模擬的方法模擬了其工作過程和影響因素,提出了控制吸附床含濕的方案,驗證了改進流程回收能的可行性並給出了操作方案,提出並分析了用熱電製器回收水蒸氣潛熱電能的方法。
  6. On the basis above, the paper sets a multiple evaluating index for the thermal environment, and then according to the critical transferring condition of the natural ventilation and the air conditioning in dwellings, the paper offers a " correction factor of energy consumption " to make a scientific and correct evaluation for the energy consumed by those sorts of buildings. further more, the author programmed the subprogram of thermal comfort results by fuzzy evaluation for the natural ventilation room so as to form an entire program, which could make it easy to numerically calculate the indoor thermal environment of residential buildings, and evaluate and analyze its thermal comfort as well features of energy conservation

    西安建築科技大學博士學位論文利用熱環境定化分析及舒適性評價計算程序,對夏季自然通風條件下建築特性與室內熱環境影響關系進行了定化計算分析,得出在滿足冬季採暖能耗要求的前提下,合理組織自然通風是改善夏季室內熱環境的有效手段;以寒地區三個城市為例,對比分析了不同地區夏季自然通風的有效時數;結合實際測試分析,提出全面改善夏季室內熱環境的系統優化設計方法。
  7. This machine adopts a whole stainless steel packing, the temperature is a number to show automatically control, heat or reduce the heat to all have a signal beacon manifestation, the electric current electric voltage size switches on to all have a manifestation, automatically feeding powder can adjust soon, spread to move part is the bean that the my plant produce product machine appropriation decelerate machine, electrical engineering is the steel plate adjustable type, the machine bottom use of upscale run a round, easy to ambulation, cool off part is automatically circulating water device, the bottom establishes keep of big capacity water tank and heat part is heat preservation economy energy type, normal production can economy in electricity quantity of 30 %, in fact use electricity charges and burn coal basic hold even

    本機採用全不銹鋼包裝,溫度是數顯自動控溫,加溫或降溫均有信號燈顯示,電流電壓大小開機均有顯示,自動喂粉可以調速,傳動部分是本廠生產的豆製品機械專用減速機,電機架是鋼板可調型,機器底部用的高檔跑輪,便於移動,卻部分是自動循環水裝置,底部設有大容的儲水箱,加溫部分是保溫能型,正常生產可用電的30 % ,其實用電費和燒煤基本持平。
  8. This machine adopts a cold plank packing, temperature means that the needle automatically control, heat or reduce the heat to all have a signal beacon manifestation, the electric current electric voltage size switches on to all have a manifestation and automatically feed powder is certainly and soon, spread to move part is the bean that the my plant produce to product the machine appropriation deceleration machine, the electrical engineering is the steel plate adjustable type, the machine bottom use of upscale run a round, easy to ambulation, heat part is a heat preservation economy energy type, normal production can economy in electricity quantity of 30 %, in fact use electricity charges and burn coal basic hold even

    本機採用板包裝,溫度是指針自動控溫,加溫或降溫均有信號燈顯示,電流電壓大小開機均有顯示,自動喂粉是定速,傳動部分是本廠生產的豆製品機械專用減速機,電機架是鋼板可調型,機器底部用的高檔跑輪,便於移動,加溫部分是保溫能型,正常生產可用電的30 % ,其實用電費和燒煤基本持平。
  9. For water conservation reasons, the water supplies department s policy on using mains water in air - conditioning systems is that they should be of closed circuit cooling type where the operational losses are negligible

    為了用水,水務署就空調系統使用由政府喉管供水所制定的政策,規定有關系統應以閉路卻方式操作,把耗水減至最小。
分享友人