精密度的確定 的英文怎麼說

中文拼音 [jīngdequèdìng]
精密度的確定 英文
rubber and rubber productsdetermination of precision for test method standardsds
  • : Ⅰ形容詞1 (經過提煉或挑選的) refined; picked; choice 2 (完美;最好) perfect; excellent 3 (細)...
  • : Ⅰ名詞1 (秘密) secret 2 [紡織] (密度) density 3 (姓氏) a surname Ⅱ形容詞1 (距離近; 空隙小)...
  • : 度動詞[書面語] (推測; 估計) surmise; estimate
  • : 4次方是 The fourth power of 2 is direction
  • : 形容詞1. (符合事實; 真實) true; reliable; authentic 2. (堅固; 堅定) firm
  • : Ⅰ形容詞1 (平靜; 穩定) calm; stable 2 (已經確定的; 不改變的) fixed; settled; established Ⅱ動詞...
  • 確定 : 1. (明確地定下) define; fix; determine; ascertain 2. (明確而肯定) definite; certain; for sure
  1. Based on the diopter status of myopia and hypermetropia, the paper presented the principle of excimer laser refractive surgery, the change of impacting cornea curvature on the cornea diopter. in this chapter, we also discussed excimer laser - corneal tissue interactions and photoablation. determine the relationship between the fluence of arf excimer laser and the cornea ablation rate, attain the relationship between the energy density and the ablation depth

    研究了激光與生物組織相互作用、光蝕作用及準分子激光消融角膜機理;首次量研究193nm準分子激光高斯光束切削量與能量關系,計算單個激光脈沖角膜切削量;發現了角膜曲率對切削效果影響,首次提出了角膜曲率半徑、切削位置與切削深關系;首次了激光光斑參數及其排列方式對術后角膜表面粗糙影響,為更實現角膜切削和提高切削后角膜表面光潔、減少手術后角膜渾濁及角膜表面術后不規則提供了理論依據。
  2. Limit of quantification ( loq ) is the lowest concentration of the analyte in a sample that can be determined with acceptable precision and accuracy under the stated experimental conditions

    量限系指樣品中被測物能被量測最低量,其測結果應具有一
  3. Calibration graph obtained by the modified procedure for ddmbac showed good linearity and its correlation coefficient was above 0. 999. the coefficients of variation and average recovery of added ddmbac were up to the mustard. the linear concentration ranges for batch determination of ddmbac were 0. 06 ~ 3. 33mg / l

    利用改進后方法對ddmbac建立了質量控制體系,其標準曲線相關系數大於0 . 999 ,線性良好,和準均符合檢測要求,線性范圍為0 . 06 ~ 3 . 33mg / l 。
  4. Considering the vectorial property of the time - average energy flow density, a new extensive definition of the light intensity has been proposed. it is expressed as the time average of the amount of energy which crosses in a unit time and a unit area, so it can be applied to measure quantity of the light intensity at any curved surface

    對于非傍軸標量光場能量傳輸規律描述則必須考慮其能流矢量特性,應當採用光強義? ?單位時間單位面積上所流過能量時間平均值來地描述某一橫截面上能流,這也與光強實際測量值是一致
  5. In this paper the water sample was digested in a high pressure disinfector and cod was determined by spectrophotometry. this method has some trait of rapidness, convenience and high accuracy

    摘要本文研究了用高壓消毒鍋重鉻酸鉀法消解環境水樣,用分光光計測cod ,本法具有快速、簡便、準特點,有良好
  6. Precision of test methods - check the acceptability of test results obtained under repeatability or reproducibility conditions and to determine final test result

    測試方法在重復性或再現性條件下所得測試結果可接受性檢查和最終結果
  7. In the paper we expound the total structure design of the diameter measurement, the working rinciple and overall structure ofthe diameter measurement are introduced, the choose of optics principle, the special optical system which consist f lens, the design of fine mechanics system, and the choose of light to current inversion as well as computer control and data processing system

    本論文完成了測徑儀總體方案設計,並對系統工作原理和總體結構進行了論述。由f透鏡構成特殊光學系統機械繫統結構設計,光電變換及微機控制與數據處理系統,最後對激光在線掃描檢測系統進行了綜合分析。
  8. Acoustics - measurement of sound insulation in buildings and of building elements - part2 : determination, verification and application of precision data

    聲學建築和建築構件隔聲測量第2部分:數據精密度的確定驗證和應用
  9. Under this condition, the linear range, the limits of detection, the recoveries, the relative standard deviations of the method to every component have been carried on

    進樣口溫220 ,檢測器溫250 。在此條件下,對各組分進行了方法線性范圍及檢測限,方法,方法
  10. Abstract : an imidazole - catalyzed acylation method of phthalic anhydride is applied to the determination of hydroxyl values of reinforcing agent is211. the analytical error is 5. 0 10 - 3. the relative standard deviation of the method is less than 0. 04 and its coefficient of variation is not more than 5. 0 10 - 3. hydroxyl values determined in different batch samples meet the design requirement completely. this method is rapid and simple, it is adaptable to conventional analysis

    文摘:以咪唑催化鄰苯二甲酸酐酰化方法測增強劑is211羥值,準高,分析誤差為5 . 0 10 - 3 ;方法好,標準偏差小於0 . 4 ,變異系數不大於5 . 0 10 - 3 ,測不同批號試樣羥值完全符合商標值,方法快速、簡便,適用於常規分析。
  11. The most commonly applied assay parameters accuracy, precision, detection limit, specificity, selectivity, calibration linearity or nonlinearity, stability, recovery, reproducibility and repeatability are carefully defined along with some recommendations required for assessing data acceptability arrived at the conference on analytical methods validation

    美國分析方法認證會議曾推薦用分析參數(準,檢測限,專屬性、選擇性、校準線性或非線性、穩性、回收率、重演性與重覆性)作為判斷實驗數據可采納性。
  12. The author developed a new method for the determination of potassium perchlorate content. as compared with the industry standard : hg3247 - 2000, the new method is not only precise but also accuracy

    摘要建立一種高氯酸鉀含量測新方法,較之行業標準hg3247 - 2000中高氯酸鉀含量方法不僅好、準也高。
  13. Accuracy trueness and precision of measurement methods and results part 1 : general principles and definitions

    測量方法與結果第1部分:總則與
  14. Accuracy trueness and precision of measurement methods and results - part 2 : basic method for the determination of repeatability and reproducibility of a standard measurement method

    測量方法與結果第2部分:標準測量方法重復性與再現性基本方法
  15. Methods : its experimentative conditions, including detected wavelength, fluid medium, disposal of special specimens, linear range of methods, minimum contents, precision, accuracy, currecy and application, have been investigated

    方法:對測方法中涉及到檢測波長、流動相、操作方法以及方法線性范圍和最低檢出量、和準等方面進行實驗研究。
  16. The results of calculation and evaluation showed that the main factors were the precision of standard curve and the excursion of instrument

    對測量不進行計算和評,結果表明,影響其測量不主要因素是標準曲線以及儀器漂移。
  17. It shows that a disadvantag ekists when a crsi is used to measure a step structure in a wavefront, but it is useful to adjust a crsi system with lcslm. 4. according to the didriction effect of an aperture, the spatial resolution of our crsi was analyzed and the transform function of our crsi was calibrated by using the psd method of a step wavefront. and some factors which are associated with the accuracy of our crsi were analyzed too

    四、從光學系統衍射效應分析了本文建立環路徑向剪切干涉儀空間解析,並利用波前功率譜概念對該干涉儀空間頻率響應特性進行了標,分析了限制該干涉儀測量主要因素以及徑向剪切比與測量關系,並指出了該干涉儀測量范圍,結果顯示該干涉儀基本上可用於準測量中低頻段波前畸變。
  18. Furthermore, it was shown that the use of micro wave - heating technique was more profitable to economize on energy resources

    該方法不僅有較高,還可以縮短測時間,提高測效率,節能效果十分顯著,是一種快速、簡便、準分析方法。
  19. In order to guaranty the goodness and stability of products, we use the baty international digital optical profile projector which is the best brand in england to inspect the quality. we can make sure that every product which is sent to customers is produced perfectly and inspected rigidly with the precision 0. 002mm 0. 00008 "

    為了保產品優良及穩,本公司採用英國最高級baty international數位投影機digital optical profile projector來做品質檢驗工作,以0 . 002mm 0 . 00008 ",來保每一個在客戶手中產品都是經過嚴格檢查而完美無缺。
  20. As to test for impurity : a certain amount of the impurity may be added to the sample to testify the accuracy and precision of the method

    對于雜質,一般取含一雜質量樣品進行分析,證明此雜質測其具有適宜
分享友人