絕對法校準 的英文怎麼說

中文拼音 [juéduìjiàozhǔn]
絕對法校準 英文
absolute calibration
  • : Ⅰ動詞(斷絕) cut off; sever Ⅱ形容詞1 (完全沒有了; 窮盡; 凈盡) exhausted; used up; finished 2 ...
  • : Ⅰ動詞1 (回答) answer; reply 2 (對待; 對付) treat; cope with; counter 3 (朝; 向; 面對) be tr...
  • : Ⅰ名詞1 (由國家制定或認可的行為規則的總稱) law 2 (方法; 方式) way; method; mode; means 3 (標...
  • : 校名詞1. (學校) school 2. (校官) field officer3. (姓氏) a surname
  • : Ⅰ名詞1 (標準) standard; guideline; criterion; norm 2 (目標) aim; target Ⅱ動詞1 (依據; 依照)...
  • 絕對 : absolute
  1. New use of atypical antipsychotics was associated with a statistically significant increase in the risk for death at 30 days compared with nonuse in both the community - dwelling cohort ( adjusted hazard ratio, 1. 31 [ 95 % ci, 1. 02 to 1. 70 ] ; absolute risk difference, 0. 2 percentage point ) and the long - term care cohort ( adjusted hazard ratio, 1. 55 [ ci, 1. 15 to 2. 07 ] ; absolute risk difference, 1. 2 percentage points )

    非標抗精神病藥物的新用與未運用抗精神病藥物中用藥30日後的死亡風險性統計學上的顯著增加相關,其中在社區居住隊列組別(正危害比為1 . 31 , 95 %可信區間為1 . 02至1 . 70 ,風險差異為0 . 2百分點)中和在長期護理組(正危害比為1 . 55 , 95 %可信區間為1 . 15至2 . 07 ,風險差異為1 . 2百分點)中都如此。
  2. The calibration of piezoelectric accelerometer is an important area of the shock and vibration measurement technology, and the calibrated piezoelectric accelerometer is divided into standard accelerometer and working accelerometer, usually standard accelerometer is calibrated by absolute method and working accelerometer is calibrated by comparison method

    壓電加速度傳感器的是振動與沖擊測量技術中的一個重要研究領域,被的壓電加速度傳感器有標加速度計和工作用加速度計之分,通常標加速度計用絕對法校準,工作用加速度計用比較
  3. In this paper, we begin with actual products designs and then combine the real conditions. on condition that technique conditions requirements were satisfied, by adopting electromagnetic field numerical analysis and experimental research, the electric field distribution inter - phase and to ground of 12kv metalclad withdraw switchgear vacuum circuit breaker is described accurately. the electric field distribution and movement in different conditions are also confirmed

    本文從實際產品設計入手,結合現實情況,在滿足技術條件要求的基礎上,通過採用電磁場的數值模擬分析及實驗研究,確地描述了12kv配電系統中置櫃真空斷路器相間及地全場域電場分佈情況,確定了中置櫃在不同情況下的電場分佈、變化情況,通過理論的計算和分析,產品的緣進行了核與驗證,通過多種方的比較,進而得到合理的布置結構和達到最佳的緣配合,為實際產品的開發和設計提供了理論依據。
  4. In order to improve the circuit ' s input impedance, which is affected by insulating resistance of electrode leading wire, terminals and printed circuit board, electrode is connected to the meter through insulating wire of high impedance which is directly welded in the printed circuit board with insulating ring. the deviation of electrode is corrected by software and the algorithm is given

    使用高阻緣線連接電極,並將高阻緣線直接焊在加有緣環的印刷線路板上,從而消除電極引線、接線端子和印刷線路板漏電放大電路輸入阻抗的影響;軟體正電極偏差,並給出演算
  5. A new method of absolute calibration of photodetector sensitivity based on spontaneous parametric down - conversion ( spdc ) biphoton field is described. the process of spdc is studied theoretically. the single photon detection probability and two - photon coincidence probability are derived and the calibration principle for photodetectors is explained. an experimental system has been set up. the sensitivity of a photon - counting photomultiplier tube was measured, and the results were compared with those obtained using conventional method

    討論了一種基於自發參量下轉換雙光子場光電探測器靈敏度的新方,著重推導了自發參量下轉換過程中產生的單光子的探測概率和雙光子的符合速率,從而闡明了測量光電探測器量子效率的原理.基於這一方光子計數型光電倍增管的響應靈敏度進行了測量,並將實驗結果與常規方測得的結果進行了比較
  6. Methods for the calibration of vibration and shock pick - ups. primary vibration calibration by laser interferometry

    振動與沖擊傳感器的激光干涉振動
分享友人