耗風量 的英文怎麼說

中文拼音 [hàofēngliáng]
耗風量 英文
blast consumption
  • : Ⅰ動1 (減損; 消耗) consume; cost 2 [方言] (拖延) waste time; dawdle Ⅱ名詞1 (壞的音信或消息) ...
  • : Ⅰ名詞1 (空氣流動) wind 2 (風氣; 風俗) practice; atmosphere; custom 3 (景象) scene; view 4 ...
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  1. In recent years at iron - making plant of pangang, the coke ratio of pig iron has reduced evidently by insisting on “ burden preparation ” course, improving quality of sinter, raising wind temperature, increasing rich oxygen quantity and injecting abundant pulverized coal into bf. the solid fuel consumption of sinter has been decreased greatly through insisting on using high - quality calces, practising high feed sintering, actualizing many techniques in solving key problems. at the same time, the energy source base management has been strengthened, and energy - saving work has made great progress, profits generated by energy - saving have exceeded a hundred million yuan

    近年煉鐵廠通過堅持「精料」方針,改善燒結礦質,提高溫,增大富氧,實施大噴煤,使入爐焦比有明顯下降;燒結堅持用好生石灰,推行厚料層燒結,實施多項技術攻關,固體燃大幅度下降;同時加強能源基礎管理,節能工作取得長足進步,節能創效益1億元以上。
  2. A one - dimensional oceanic mixed layer model with the m - y level - 2. 5 turbulence closure schemes is employed. the rate of energy loss by breaking waves is estimated by parameterization and incorporated into the model as a source of turbulence kinetic energy ( tke ) by modifying the existing surface boundary condition of tke equation. the velocity field and turbulence energy budget are calculated under different forcing conditions ( the results given below are for a wind speed of 20 m / s. )

    採用一維2 . 5階湍封閉混合層模式,根據參數化方法對波浪破碎導致的能散率進行了估計,通過改變湍動能方程的上邊界條件引入波浪破碎對湍動能生成的影響,計算了不同應力強迫下的混合層流場結構和湍能收支(下述給出的結果是取速為20m s得到的) 。
  3. Laboratory measurement of the power dissipation characteristics of aeolian vibration dampers for single conductors

    單根導線吹震動阻尼器功率散特性的實驗室測
  4. Energy consumption of heating rooms will increase when air exchange rate become large. because the mechanisms of heating methods used currently, such as radiator heating, ceiling heating and warm - air heating, are different from each - other, the indoor thermal environment is not the same when each one of them employed for room heating. for enhancing energy efficiency of heating rooms, indoor thermal comfort and energy saving effects should be investigated when natural ventilation is used to make a good air quality indoors

    房間換氣次數的增加勢必導致供暖房間能加大,頂棚輻射、散熱器和熱等三種採暖方式由於供暖機理不同,形成的室內熱環境特徵不同,通換氣時產生的通熱損失也有所區別,為了提高大換氣房間的供暖節能效果,必須對不同供暖方式在大換氣情況下的熱舒適性與節能效應進行研究。
  5. A reasonable position of driving nozzle helps to achieve the maximum material flow that also depends on other parameters such as backpressure, properties of conveyed material and driving gas. it is observed that, an increase of convergent section angle is harmful to the pneumatic conveying system, and also influences on the mass flow rate of conveyed material, the distribution of static pressures in injector and the pressure drops of conveying pipe. in addition, within a reasonable scope of air mass rate, increasing the driving jet velocity is more advantageous than enlarging the dimension of driving nozzle

    試驗研究發現,氣體噴嘴位置對氣固噴射器的輸送能力影響最大,氣體噴嘴存在某一最佳位置,而這一最佳位置與背壓、輸送物料特性和輸送特性相關聯;氣固噴射器的收縮角對其輸送能力、內部靜壓分佈和輸送管阻力特性均有適影響,收縮角增大對整個輸送系統均不利;在適當的輸送范圍內,提高氣體噴嘴出口速度比擴大氣體噴嘴尺寸更為有利,但氣體噴嘴出口速度過高會增加氣固噴射器和輸送管內的能,給輸送帶來不利的影響;系統背壓與氣固噴射器的氣體噴嘴出口速度的選取有關。
  6. Electromotor joins with high efficiency selected water pump, scm ( single chip micyoco ) control system commands water pump according to cooling water temperature which substitutes traditional strap - driving mechanism pump and forms tael - level intellectualized control cooling system combining with electromotion control of cooling fan. consequently it realizes that water pump and fan autoregulate with engine working status and assures t hat cooling water temperature keeps in the best range all the time and advances the reliability of engine working and realizes exact control of cooling water temperature in deed

    選用高效率水泵與電機聯接,改由單片機控制系統根據冷卻水溫控制水泵的工作,代替傳統的皮帶帶動的機械水泵,結合冷卻扇的電動控制形成兩級智能化控制的冷卻系統,從而,實現了水泵和扇轉速隨發動機工況變化的自動調節,真正實現了冷卻水溫的精確控制,保證了冷卻水溫始終保持在最佳范圍內,大減少傳熱損失降低油,並提高了發動機工作的可靠性。
  7. With the impact test of conditioner airport and anti - dust mesh settings on heat exchange gas flow, the paper illustrates that the improper design may reduce gas flow, influence the refrigerating capacity of the system, and increase energy consumption

    摘要通過空調口及防塵網設置對換熱氣流流影響的測試,結果表明,若空調口及防塵網設計不當,則可能造成氣流減少,並影響系統製冷,增大能
  8. In this paper, from the viewpoint of basic automatic control system, a cooling tower supervisory controller is designed and tested by applying it on the digital simulator to real time control the tower airflow and tower fan sequencing in central air - conditioning

    摘要從集中空調冷卻水側基本自動控制系統的局部角度出發,設計了冷卻塔扇上位機控制器,對和運行臺數進行實時控制,並通過模擬試驗分析了其對系統控制穩定性和系統能的影響。
  9. It will be useful to increasing drying - rate, improving drying quality and decreasing energy consumption in heat - air and vibrating fluidisation drying the distillerys grain and the damp sticky substance

    這對于熱乾燥、振動流化床乾燥和組合方式下乾燥酒精糟等高濕高粘物料,在提高幹燥速度、乾燥質和減少能等方面具有重要的指導意義。
  10. And, this thesis return as to it ' s measure to measure the proceeding error margin the analysis, and was analyzed by error margin the enthalpy different laboratory matchs the gb / t 7725 - 1996 standard, can be used for measuring the making the cold and making the heat ' s ability, the consuming, the cop, the breeze deal under the steady state or not steady state of air condition of diagraph room, and it can also test the influence of the four channels change to the face valve and and the electronic expanding valve to the whole function of the air condition

    而且,本論文還對其測進行誤差分析,經誤差分析該焓差室符合gb t7725 - 1996標準,可用於測房間空調穩態及非穩態製冷能力和制熱能力、工、 cop以及空調器室內機組的,並能測試四通換向閥、電子膨脹閥等控制元件對空調器整體性能的影響。
  11. And because the power system must continuously match electricity consumption with generation, it cannot easily accept a large increase in the unpredictable and intermittent power produced from renewable wind, ocean and solar resources

    同時由於電力系統必須持續依據電力消調配生產,因此很難大採用力、海洋和太陽能等難以預測的間歇性再生能源。
  12. Pf series air fans are new low - speed high - flow - rate tube - axial fan. wich represents advantages of high flow, light weight, low noise and lower power consumption. they are key equipment of tunnet ventilation in houses of poultry & livestock poultry

    Pf系列排扇是新型的低速大流軸流機,具有流大、重輕、噪音低、電省等優點,是畜、禽舍縱向通的關鍵設備。
  13. The new device consists of paint - drying box, heat carrier boiler, heating pipe, expansion tank, gas separator and oil tank, etc. the data of two applied examples shows that heat carrier paint drying method is able to make painting - drying cost drop by 88 %, compared with the conventional one, that it has some advantages such as uniform temperature field, good appearance and lower costs, compared with conventional hot air convection mode

    該裝置主要由熱載體烤漆爐、輻射加熱管,熱載體爐、膨脹器、油氣分離器和儲油槽等組成。應用實例的測試數據表明,與傳統的遠紅外電加熱鋼瓶烤漆方式相比較,鋼瓶熱載體烤漆節能和降低能費用十分顯著,能費用降幅達到88 。與熱爐對流烤漆方式相比較,熱載體烤漆方法不僅節能,而且烤漆爐溫度場均勻穩定,同時烤漆的外觀質也得到了明顯提高。
  14. The means we often take to handle the issues is to increase the quantity of ventilation, but this will also bring us more energy consumption

    處理這些污染問題的常用辦法是增加通或新,但這無疑會造成能增加。
  15. Energy conservation and and reformation of power plants " heat installation affect a lot on the efficient performance of opertion of power plant. pump and fan take a large proportion in power plant and resume much electric energy. so there is much energy conservation pationlity in them. and we should have strong tools and theories " support to reform them. we can combine the theory modeling and engineering design manufacture by the bussiness software such as fluent. in order to take full advantage of the powerful function of fluent and increase absolutely its conveniece and interaction, we should develop fluent secondly. this paper puts the idea firstly demostricly to substitute the performance test of pump and fan to get the integrative system of the optimization and computer aid design, and so we can increase greatly of the efficiecy and quality of the facility reformation. the main idea about the secondary development of fluent in this paper is based on the secondary development of gambit, the modeling and meshing s oftware of fluent, and simplify the modeling and meshing of gambit. meanwile, the data management base on web browser kind is adopted for the convenience of optimization and parameterization, and the journal files createdly recently can get new medeling and meshing files that can be used by fluent. so the designer can focus on the computer scheme and the result analysis without care the fussy designing and optimiziation. so we can increase greatly the optimization efficiency

    泵與機在電廠中占較大數比例,且消電能,節能潛力巨大,對其改造需要強有力的工具和理論支持,用商用cfd軟體如fluent可實現泵與機改造中的理論模擬與工程設計製造間的結合。為了充分發揮fluent的強大功能,又能最大程度地提高其方便性與交戶性,應對其進行二次開發。本課題在國內首先提出對fluent進行二次開發,替代泵與機性能試驗,形成一體化的優化、輔助製造系統,可大大提高設備改造的效率與質,其主要思想是基於fluent的cad構體軟體gambit進行二次開發,簡化了泵的構體過程,同時,為了優化及參數化方便,採用基於webbrowser的數據管理方式,生成新的記錄文件同時產生新的fluent計算能識別的圖形網格文件,這樣就將設計優化者從繁瑣的圖形設計及優化中解脫出來,專注于對計算方案的確定及計算結果的分析,極大地提高了設計優化的效率。
  16. The experimental results indicate that when the air flow rate is determined, the key problem for energy saving is how to keep the indoor thermal comfort at a suitable level and reduce the difference between the internal and external temperature of the room. a formula is gained for calculating the critical values of air exchange rate. when ventilating rate is greater than the value, radiating heating is the better way for energy saving, or else, convection method in heating is more suitable

    實測還指出,當通一定時,如何保證人體熱舒適度不變而減少室內外氣溫差將成為大通房間節約採暖能的關鍵,本文結合圍護結構傳熱機理,在對三種方式的能狀況進行理論分析的基礎上,提出了換氣次數的節能臨界值,若換氣次數高於此值,則輻射供暖是較好的選擇,否則,散熱器供暖是較好的方法。
  17. Taking an office building in guangzhou as an example, this paper investigated the energy consumption of a central air - conditioning system with primary return air using heat pipe air - conditioner at different indoor design temperatures

    摘要以廣州地區的辦公建築為例,就一次回集中空調系統在空氣處理過程中採用熱管式空調機組時,不同室內設計溫度下的空調系統能進行了分析,並且與常規的一次回集中空調系統的進行了比較。
  18. According to the statistical data, in china only the power consumption of fans and pumps take the 40 % of annual electric power production

    據統計,我國機、水泵年佔全國發電的約40 。
  19. Vav ventilation control can save the energy comsumer effectly, meanwhile, it can control the pressure and temperature in the laboratory

    控制能最大限度地節省實驗室里的通設備的能,同時達到控制房間里的壓力差和溫差控制
  20. Proper arrangement of them significantly reduces the energy consumed and noise level and ensures the input power and noise index, solves the problem of insufficient air volume supplied, and improves the indoor thermal comfort effectively

    通過對這些部件的合理布置,大幅度降低機組能及噪聲,保證了產品輸入功率及噪聲指標,解決了傳統盤管在實際運行時小的問題,有效提高了空調房間的舒適性。
分享友人