自恢復電路 的英文怎麼說

中文拼音 [huīdiàn]
自恢復電路 英文
self repairing circuit
  • : Ⅰ代詞(自己) self; oneself; one s own Ⅱ副詞(自然;當然) certainly; of course; naturally; willin...
  • : Ⅰ形容詞1 (重復) repeated; double; duplicate 2 (繁復) complex; compound Ⅱ動詞1 (轉過去或轉過...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • 電路 : [訊] circuit (ckt); electric circuit; electrocircuit電路板 circuit board; 電路保持 guard of a c...
  1. This paper mainly aims at the characteristics of the hardware and software structure of the parallel computer on satellite, and has fulfilled researches of fault tolerant technique in three aspects of control theories and engineering : the first research of the system level fault - tolerant module is based on the system structure of the parallel computer on satellite, a kind of cold backup module and a kind of hot backup module for multiprocessor computer have been put forward. then the research of software fault tolerant technique which is based on the operate system named rtems has been carried, the mission level fault - tolerate arithmetic and the system level fault - tolerate mechanism and strategies based on the check point technique have been put forward, at the same time the self - repair technique of software which has used the technique of system re - inject has been studied. finally the technique of components level fault - tolerant based on fpga has been studied, a kind of two level fault - tolerant project which aims at the fault - tolerant module of the parallel computer on satellite has been put forward, and the augmentative of circuit that project design realization need is little, this project can avoid any breakdown of any part logic circuit of the fpga

    本課題主要針對星載并行計算機體系結構及軟體結構的特點,從如下三個方面進行了容錯控制理論研究和實踐工作:首先進行了基於星載多cpu并行計算機體系結構的系統級容錯模型研究,提出了一種多cpu冷備份容錯模型和一種多cpu熱備份容錯模型;然後進行了基於rtems操作系統的軟體容錯技術研究,提出了任務級容錯調度演算法以及基於檢查點技術的系統級容錯機制和策略,同時研究了利用系統重注入進行軟體在線的容錯技術;最後研究了基於fpga的部件級容錯技術,提出了對容錯模塊這一星載并行計算機關鍵部件的兩級容錯方案,實現該方案所需增加的少,可避免板級晶元以及fpga晶元內部任何邏輯發生單點故障。
  2. In this paper, the design of a specific chip for circuit emulation based on ip is put forward and realized and the main functional modules and the key algorithms including an all - digital adaptive clock recovery method and a dynamic depth buffer algorithm are described in detail

    文章根據相關標準提出並實現了一種模擬專用晶元的設計方案,並對其中主要功能模塊和關鍵演算法作出了詳細說明,包括一種全數字的適應時鐘方法、動態深度緩沖演算法等。
  3. Shunt power capacitors of the self - healing type for a. c. systems having a rated voltage up to and including 1000 v - part 2 : ageing test, self - healing test and destruction test

    額定壓在1000v以下含1000v的交流型旁容器.第2部分:老化試驗試驗和破壞性試驗
  4. Combined with the practical situiation in distribution network, it ' s suitable to select graph algorithm as the theoretical algorithm base. based on structure variable dissipated network theory, this thesis detailedly discusses the transforms of base - to - shape, shape - to - base, vertex - to - arc, arc - to - vertex, over - heated arc dectection, load allotting, load balancing and optimum restoration

    本論文基於變結構耗散網理論,詳細討論了基形變換、形基變換、點弧變換、弧點變換、過熱弧搜尋、負荷分配、負荷均衡化以及優化非故障停區域供等一系列與饋線動化功能相關的處理演算法。
  5. Manipulation that any metal into the cmp battery connection or the power supply fan - out, and cause short - circuit, at this time, the battery can protect it automatically quickly, the condition of short - circuit will vanish, and the battery get right automatically and work properly, which means 100 % safe of protecting the laptop

    任何金屬對cmp池介面或源輸出端操作短時,池都會動快捷的保護起來,短狀態消失,正常工作不鎖死,即保證筆記本腦的100 %安全
  6. Abstract : the rechargeble batteries are used for backup power internal electrically equipments and instruments. but batteries lifetime usually is shorten by overwork and then malfunctions of equipment are induced. to avoid the complexion described above, the protection circuit against overwork is designed. it is based upon the voltage comparator and regulator. it will light up a red led when the volume of the batteries discharged close upon 50 % ; it will switch off the load automatically when it discharged closing to 80 % of their energy capacity, thus overwork of batteries can be avoided and lifetime may be extended

    文摘:用蓄池做后備源的系統(或設備) ,常因過放導致池提前報廢而造成設備故障.根據壓隨容量變化的規律,利用壓比較器和壓基準源設計製作了池放保護,當池放量接近容量的50 %時,啟動預警信號;當池放量達到容量的80 %時,動切斷負載,防止池過度放,延長池壽命,保證系統(或設備)在供正常后能正常運行
  7. My net assistant can optimize settiongs automatically, if you are an advanced user, you can optimize settings manually ; backup and restore with the optimization, the ones that can make users relaxed will resume the state before optimized, in order to ensure the system security. 2. maxmtu automatically discovery : specifies whether microsoft tcp ip will attempt to discover the largest packet size the mtu over the path to a remote computer

    1 .領先的網優化項目,全面提升網性能:軟體開發組通過對windows操作系統環境9x me nt 2000 xp 2003下的500臺腦的實際評測分析,主分析評測出絕對領先的多達29項的網優化項目,通過智能化的動優化向導,將網系統參數設置得更合理,讓用戶的網性能發揮到最高點為方便高級用戶,軟體內置了詳細的定義手工優化系統,可以更精確的設置各個項目最安全最先進的系統同步備份與還原功能,可以讓用戶輕松的將系統到優化以前的狀態,以保障系統的優化安全。
  8. The feeder net model for distribution automation is built based on the nod information matrix and the line information matrix, and the nods represent the switches and the fault indicator in the distribution net. the method of fault locating offered by this paper called line fault probability method, which locates fault by calculating the fault probability of line in the net. this paper also provides a method called volts d. c. for restoration and offers the regulation of restoration

    採用節點、支信息矩陣來描述配,形成面向故障動化處理的網數據結構;提出了基於支故障概率的故障定位演算法,並結合短流特性判據法來定位故障支;在定義直流等值網的基礎上,提出了優化供的直流壓降法;開發了配網故障動處理軟體系統,並用於實際配動化工程中。
  9. The distribution network automated system ( das ) is a management information system, including computer software and hardware technology, the computer network technology, the automatic control technology, the data communication technology and electrical power system technology, and it is utilized to acquire the data from power distribution network, monitor operation, position breakdown fast, isolate the failure, restore the power supply and administrate need, what ’ s more, it reduces the time of power cut effectively, improve the reliability and quality of power supply

    動化系統( das )是集計算機軟硬體技術、計算機網技術、動控制技術、數據通信技術及力系統相關技術於一體的信息管理系統,為配的數據採集、運行監視、快速故障定位、故障隔離、供以及需求側管理等提供了有力的技術手段,能夠有效地縮短事故停時間、提高供可靠性、改善供質量。
  10. The intelligent optical switch can automatically recover the circuit service and resist multi - point failure through the meshed backbone in the case of cut fiber links or invalid parts, thus guaranteeing a high reliability of service transmission

    智能光交換機可在光纖鏈被切斷或其它部分失效的情況下,通過網狀骨幹網業務,並可抗多點失效。
  11. The current spic has the functions of under - voltage and over - current checking, which can protect the system by automatically stop working when the system is in trouble until the trouble is eliminated

    當前的智能功率集成一般都具有欠壓檢測和過流檢測等功能,在系統出現異常時動停止工作直到故障排除后才正常工作,從而保護系統。
  12. The ups shuts down and will not transfer to the bypass mode when a short circuit occurs on output of the unit. after the short circuit being removed the ups will operate normally again. at short condiion, the fault led lights as a warning to end users

    當負載發生短時,本系統動關機,並不轉換至旁,待短解除后,在短情況,故障燈亮同時發出長鳴,警告使用者
分享友人