范性流變量 的英文怎麼說

中文拼音 [fànxìngliúbiànliáng]
范性流變量 英文
amount of plastic flow
  • : 名詞1 [書面語] (模子) pattern; mould; matrix 2 (模範; 榜樣) model; example 3 (范圍) boundar...
  • : Ⅰ名詞1 (性格) nature; character; disposition 2 (性能; 性質) property; quality 3 (性別) sex ...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  1. The structure of air - blast pipe was improved on. an orienting object was installed based on theoretical analysis, that increase the spraying span. it has been found that both spraying span and droplets uniformity improved, by installing the orienting object. according to the results of a great number of experiments, orderliness of droplets diameter along the spraying span was researched, and rational spraying span of air - assisted sprayer was suggested

    通過試驗檢驗噴霧機樣機的噴霧能,並提出對各項參數的優化設計方案。通過正交試驗和對比試驗對霧滴取樣,證明導器的安裝不僅增加了噴幅,而且還提高了霧滴均勻系數。根據大試驗的結果分析,找出了霧滴直徑在噴幅方向上所呈現的化規律,並提出了合理的噴幅圍。
  2. According to the experimental data of droplet size 、 particle spectrum range 、 droplet cone shape 、 flow rate 、 cover area and cover area rate which obtained through changing the pressure of power sprayer and the nozzle diameter in greenhouse , this paper made comparative analysis on atomizing performance in same pressure and different nozzle type between same nozzle type and different pressure. the conclusion is that : the ejection rate and the droplet cone shape change with the variation of pressure and nozzle diameter , average particle diameter decreases obviously and particle quantity increases obviously with the increase of pressure and decrease of nozzle diameter. these results will lay experimental foundation for precise spraying 、 low pollution and highly effective operation

    本文根據溫室內動力噴霧機壓力與噴嘴孔徑的化影響霧滴大小、粒譜圍、霧錐形狀、、覆蓋面積及覆蓋面積率的試驗數據,對相同壓力下不同噴嘴型號和相同噴嘴型號時壓力不同時的微粒化能進行對比分析和研究,得到如下結論噴出與霧錐形狀隨著壓力和噴嘴孔徑大小化而化;平均粒徑隨著壓力的增加和噴嘴孔徑的減小而明顯減小;粒數隨著壓力的增加和噴嘴孔徑的減小而明顯增多,為精噴、低污染、高防效的防除作業奠定了實驗基礎。
  3. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用圍、兩種運行方式供電可靠的高低、人身安全、通訊干擾和運行維護工作等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中點接地方式的選擇問題進行研究。論文首先對10kv電網的中點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電化、中點電阻取值大小、接地點接地電阻值化等多種影響因素的情況下,對中點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  4. The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method

    本論文從目前空調工程中使用的水系統入手,研究了盤管換熱器在部分負荷下水與換熱的非線關系,分析了文獻中介紹的旁通管通能力選擇的不足之處和一次泵水系統採用壓差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次泵水系統中壓差旁通控製法、回水溫度控製法、負荷控製法的精確,並得出了在一次泵水系統的工況轉換時,採用負荷控製法能使冷水機組及其相應水泵在啟停時的負荷圍較小,更符合建築物的冷需求,節能效果較好的結論。
  5. Based on the analyses of the flow and sediment characteristics and evolution trend of the river bed of the fuling reach in the yangtze river before and after the impoundment of the three gorges reservoir, the water level, velocity variation and influenced range in the fuling reach before and fifty years after the operation of the three gorges reservoir with the construction of the fuling dock and four discharge combinations are calculated by using a two - dimensional flow mathematic model

    摘要在分析長江涪陵段的水沙特和三峽水庫蓄水前後該河段河床演趨勢的基礎上,運用二維水數學模型,分析了4種組合情況下在三峽水庫運用前和運用50年,涪陵港區碼頭修建前後的水位、化及其影響圍。
  6. Examinations of steady status and analysis of dynamic experiments have been conducted on band - tube evaporator and parallel - flow condenser using r134a refrigerant. the steady examination show that the model error was under the allowable error, the inlet mass and enthalpy disturb experiments indicate that the subsection model, be good at reflecting the change of parameters of the heat exchanger, accord with the basic principle of thermodynamics theory and the actual work status. hence, the subsection simulation model research has important benefits both on theory and engineering application

    在進行模擬試驗時,以使用r134a作製冷劑的管帶式蒸發器和平行式冷凝器為對象,完成了穩態模擬計算、試驗和動態模擬分析,穩態計算結果和試驗數據對比表明,其誤差在允許圍內;進口質和焓值的擾動試驗結果表明:本文所建的區段式換熱器模擬模型,能很好的反映換熱器能參數的動態化,與系統熱動力學理論和冷凝器、蒸發器的實際工作過程基本一致。
  7. The test results demonstrate that this prototype has excellent comprehensive performances such as small bulk, lower weight, high efficiency, high steady precision, fast dynamic response, wide range input voltage, good output waveforms, strong over - load and short - circuit ability, and strong function with different nature load and three - phase unbalanced load

    試驗結果表明,該器具有體積重小、換效率高、靜態精度高、動態響應快、輸入電壓圍寬、輸出波形質高、過載與短路能力強、帶不同質負載和帶三相不平衡負載的能力強等優良的綜合能。
  8. O curve of dsdp607 v30 - 97 show that loess began to deposit on the terrace of the yellow river about 1. 20 ma b p, and passed thirteen climatic changes from drier and cooler to warmer and wetter later. the turn of sedimentation from alluvium to loess, an event of transformation from accumulation to down - cut of the yellow river, indicates a sharp tectonic uplift occurred around 1. 2 ma b p. key words : loess - paleosol ; susceptibility ; climatic changes ; tectonic movement ; yellow river ; yangfan section

    通過對楊剖面黃土地層巖特徵沉積結構質磁化率和頻率磁化率的分析及與深海氧同位素曲線的對比,劃分了剖面地層,初步確定了黃土沉積始於1 . 20 ma b p ,黃土沉積以來該區發生了13次大的乾冷暖濕氣候化沉積轉型指示河強烈加積轉為河侵蝕,代表約在1 . 20 ma b p發生過一次強烈的構造抬升事件。
  9. Among them, phase shifted ( ps ) full bridge ( fb ) zero - voltage - switched ( zvs ) pulse - width - modulated ( pwm ) dc / dc converter has strong competitive power in big power capacity fields. but it has some limitations such as smaller load range with zvs and larger circulation energy. the ps - fb - zvs - pwm dc / dc converter with a saturable inductor utilizes saturable inductor s critical saturable current characteristic and storage energy, to enlarge load range with zvs and improve output efficiency under light load

    其中,移相控制零電壓開關脈寬調制dc / dc全橋換器在大容領域很有競爭力,但它具有實現零電壓開關負載圍小,循環能大等限制,帶飽和電感的移相控制零電壓開關全橋換器利用飽和電感的臨界飽和電及儲能,來擴大零電壓開關( zvs )的負載圍,提高輕載時的輸出效率,具有非常重要的研究價值。
  10. The " net cash flow from operating activities / net profit ", a cash flow indicator that is emphasized both at home and abroad, was first time to be treated as one of the variables for corporate performance. the listed companies of manufacturing industry were grouped according to their asset scale and industry property. the empirical study of equity structure and corporate performance were carried out through combining the empirical analysis and theoretical analysis and by using stochastic variable intercept paral data mode and sas software package

    本文以製造業303家上市公司為總樣本,確定了6個股權結構、 7個經營績效,並在經營績效中,首次引入了國內外尤為關注的現金指標? ?盈餘現金保障倍數;將製造業各次類上市公司,按資產規模和行業質進行劃分,採用實證分析與規分析相結合的方式,運用計經濟學建模方法? ?隨機影響截距平行數據法,應用sas統計軟體,對我國上市公司的股權結構與經營績效進行實證研究。
  11. This paper studies on used the ac servo system based on ti dsp ( lf2407a ) and the foc and digital signal processing thorem, achieves following results : algorithm. we employ svpwm ( space voltage pwm ) algorithm, improve the efficiency of the electric source, and decrease the harmonious elements. we build the mathematic model of the system and simulate it on matlab platform, dsigne segmented pid regulator to adapt variable speed and widen the speed range. measurement. the velocity and electric current measuring, we adopt multi - sampling - rate and digital filter principles. as more improvements we make, the whole system gets a good results. pc control. the complete controlling system can be controlled remotely. so we develop the pc controlling program.

    採用磁場定向脈寬調制演算法,提高了電源利用率,降低了逆電壓的諧波,改善了電機的運行特,降低了對電網的污染;在matlab平臺上建立了交永磁同步伺服電機和電壓空間矢脈寬調制控制系統的數學模型,在模擬的基礎上,對傳統pid調節器進行了改進,提出轉速調節器和電調節器採用分段pid結構,根據給定轉速所處的區間,自動選擇相應pid調節器的參數,拓寬了調速圍,提高了控制精度。
  12. But due to the existence of the fault resistance, the branch current, the zero sequence mutual coupling and so on, the apparent impedances and protection scope of distance protection will change, thereby affecting the performance of distance protection and the safety operation of power system

    然而,由於過渡電阻、分支電和零序互感等因素的影響,會改距離保護測阻抗的大小,造成距離保護動作圍的擴大與縮小,從而影響距離保護的能,威脅電力系統的安全運行。
  13. According to the supply system composed by parallel connection water pump, many kinds of operation proposals in a single pump were put forward to provide the greatest possible flow on both sides of the demarcation point in the scope of the flux changes ; identified the system of pumps, electromotor, speed governor imitate method of characteristics curve of the power device and its rotating speed, efficiency, energy consumption calculation under different condition ; the analytical methods used for the operational plan for comprehensive evaluation of the economic and safety and optimal results

    摘要針對由並聯水泵組成的供水系統,提出了在以單泵可能提供最大為分界點的兩側圍內具有多種運行方案;確定了在不同工況下,該系統中水泵、電機、調速器特曲線的擬合方法及其各動力裝置中轉速、效率、能耗的計算式;採用解析的方法對各種運行方案進行了經濟和安全綜合評價,並給出最優結果。
  14. This paper analyses the type, function and characteristics of usual proportional control valves and raises a new modificative version in the light of their drawback. that is, basing on the principle of flow amplification and electrical feedback and throughout calculation and analysis on flow closed loop control and pressure flow combination., determination of the minimum controlled pressure difference as well as flow controlling range and structure of main valve and research of the dynamic and static characteristic, the paper puts forward control principle of " flow - load pressure change - displacement revision " and pressure / flow double closed loop, and further expounds that using a proportional controller and a electric mechanical transducer can separately serve the control function of pressure or flow as well as flow pressure combination

    本論文分析了目前常用比例閥的類型、功能、特,並針對其不足提出新的改進方案,即:以放大,電反饋兩個原理為基礎,通過對閉環控制及壓力復合的計算分析、確定上最小控制壓差及控制圍,確定主閥結構、功能特研究等,提出了「? ?負載壓力化? ?位移修正」的控制原理和壓力雙閉環控制原理,並進一步論述了利用一個比例控制器和一個「電?機械轉換器」就可完成獨立的壓力或控制功能以及壓力復合控制功能。
  15. Industrial - process control valves. flow capacity. inherent flow characteristics and rangeability

    工業過程用調節閥..固有和幅度
  16. Research on retrieval of gps water vapor and method of rainfall forecast are keen field which draws all attention from wide world. the dissertation is accomplished on the basis of sino - italy collaborative project - ' the integral system of flood risk programming, monitoring and real time forecasting " and the primary achievements and conclusion reached include : ( 1 ) a reasonable design has been made for gps water vapor monitoring network according to the theory of gps satellite signal propagation and vertical distribution of water vapor and local synoptic characteristic of binjiang basin, the effective area where water vapor can be detected by gps station has been determined under different cut - off angles. the conclusion has been reached that 3 ~ 4 gps receivers are enough for water vapor monitoring in binjiang basin

    Gps水汽反演和降雨預報研究是當前氣象遙感應用的一個前沿探索領域,本論文依託于中意科技合作項目「洪水風險規劃、監測和實時預報的集成系統」 ,主要成果體現在以下方面: ( 1 )提出了一個合理的gps水汽監測網設計方案根據gps衛星信號傳播原理和水汽垂直分佈規律以及域天氣的地方特徵,確定了不同高度截角下一個gps站所能測定大氣水汽含的有效圍,得出了濱江域只需要3 4個gps接收機就足以反映域水汽化的結論。
分享友人