蒸餾冷凝器 的英文怎麼說

中文拼音 [zhēngliùlěngníng]
蒸餾冷凝器 英文
distiller conde er
  • : Ⅰ動詞1. (蒸發) evaporate2. (利用水蒸氣的熱力使食物熟或熱) steam Ⅱ名詞[中醫] (將藥物隔水蒸熟) steaming
  • : 餾動詞(蒸熱熟食) heat up; reheat
  • : Ⅰ形容詞1 (溫度低; 感覺溫度低) cold:冷水 coldwater; 你冷不冷? do you feel cold?; are you feeling...
  • : 動詞1. (凝結) congeal; curdle; coagulate 2. (注意力集中) fix
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 蒸餾 : [化學] [物理學] distillation; distill
  1. Azeotropic distillation column condenser

    共沸
  2. In this way it can prevent from the phenomenon of filler block caused by scrap iron and its life is prolonged. all parts that will contact ethanol in the device such as condensor. buffer tank, cooling snake pipe are made of stainless steel in order to guaran - tee that the finished product, ethanol, is not polluted

    塔體採用不銹鋼製作,從而防止了鐵屑堵塞填料的現象,延長了裝置的使用期限。本裝置中凡接觸酒精的設備部份如、穩壓罐、去口蛇管等均採用不銹鋼,以確保成品酒精不被污染。
  3. Model zt has two specifications, each specification is equipped with distillation tower, still, condusator, buffer - tank, measurer of specific gravity

    Zt型有zt - 200 、 zt - 300 、兩種規格,每種規格包括相應配套的預熱塔、、穩壓罐、比重測定
  4. Something, such as the thread of a screw or the spiral condenser in a still, that resembles a worm in form or appearance

    有螺紋狀的物品某物,如螺旋線或的螺旋,在構成或外表上像蠕蟲
  5. The condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    建立了空氣卻實驗臺,熱管的加熱方式為電加熱,工質為水.在1 1模型上對分離式熱管管內結換熱特性、不性氣體對結換熱的影響及不性氣體的擴散規律進行了試驗,得出分離式熱管有一最佳充液率,其值為45 %左右;結換熱系數隨著汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不性氣體對分離式熱管的結換熱僅影響段下部較小部分,通過排氣閥排出不性氣體可有效地改善段下部的結換熱;隨著壓力的增加,不性氣體對分離式熱管段的影響減少.這些結論可用於分離式熱管換熱的工程設計和控制
  6. Abstract : the condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    文摘:建立了空氣卻實驗臺,熱管的加熱方式為電加熱,工質為水.在1 1模型上對分離式熱管管內結換熱特性、不性氣體對結換熱的影響及不性氣體的擴散規律進行了試驗,得出分離式熱管有一最佳充液率,其值為45 %左右;結換熱系數隨著汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不性氣體對分離式熱管的結換熱僅影響段下部較小部分,通過排氣閥排出不性氣體可有效地改善段下部的結換熱;隨著壓力的增加,不性氣體對分離式熱管段的影響減少.這些結論可用於分離式熱管換熱的工程設計和控制
分享友人