衰減測量器 的英文怎麼說

中文拼音 [shuāijiǎnliáng]
衰減測量器 英文
attenuation gauge
  • : 衰動詞(衰弱) decline; wane
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 衰減 : attenuation; decay; damping; reduction; rejection; weakening; deamplification; dampening; dying o...
  • 測量 : measure; survey; gauge; meter; measurement; measuring; surveying; mensuration; metering; gauging;...
  1. Some by - products of this work can be used as routine tools in the uv laser laboratory. commercial video ccd cameras are used to image uv laser and soft x rays, window glass as a fluorescer is used to indirectly measure the uv laser beam profile with high energy density, and a special glass which permits uv light to pass through while absorbs the visible, is introduced into the uv beam profiling in strong visible stray light environment

    實驗中發展了一些技術,例如用可見光視頻ccd直接紫外激光的光束分佈和激光等離子體產生的x光二維圖象,利用窗玻璃作為熒光體密度較高的紫外光束分佈,利用可見吸收紫外透射玻璃製成的有嚴重背景光的紫外光束分佈,可以作為實驗室的常規工具,並有一定的推廣價值。
  2. 53 maize standard samples diffuse reflectance spectra were collected from 4000cm - 1 ~ 10000cm - 1 at 8 cm - 1 resolution on perkin - elmer spectrum one nts near - infrared instrument at different energy level. 3 samples were scanned 10 times repeatedly at 100 %, 76 % and 34 % energy level for energy variance analysis

    結果表明,隨著儀降低,模型相對標準偏差( rsd )有增大趨勢,儀相對能從100到18后,模型預值rsd從2 . 5增至4 . 72 。
  3. Fibre optic interconnecting devices and passive components - basic test and measurement procedures - part 3 - 34 : examinations and measurements - attenuation of random mated connectors

    纖維光學互連件和無源件基本試驗和程序第3 - 34部分:檢查和隨機配接連接
  4. Fibre optic interconnecting devices and passive components - basic test and measurement procedures - part 3 - 34 : examinations and measurements ; attenuation of random mated connectors

    纖維光學互連件和無源元件.基本試驗和程序.第3 - 34部分:檢查和.隨機插合連接
  5. Based on the model of resource survey spaceborne laser altimeter, the noncooperative regulable attenuation module, including angular measure setting, beam splitter, energy meter, attenuator and simulant target, was designed and founded

    結合激光高度計原理樣機,設計並建立了非合作目標可調法模塊,該模塊包括角度裝置、分束片、能計、以及模擬目標物。
  6. In the paper, prescale technology, interpolate method, averaging method and multiple period synchronization method are used to measure the frequency accurately. diode demodulating technology, and power attenuated method or probe coupling & water load technology are employed to measure the power of high power microwave. isothermal technology is used to improve the stability of demodulator and to expend the range of square linear region

    本文採用預分頻法、內插法、多周期同步法、平均法實現了頻率的精確;利用二極體檢波技術,結合法或探針耦合+水負載技術實現了大功率微波功率的;採用恆溫技術提高了二極體檢波穩定度;完成了單片機串口通信協議設計和系統電磁兼容的分析和設計。
  7. 3. the new microwave power supply ( mps ) can work in vacuum and its power measurement is convenient. the output power could be adjusted with the change of control voltage, and the reflecting power could be gotten by measuring the output voltage of attenuator and detector

    ( 3 )可在真空下穩定工作的新型微波源功率的較為方便,通過改變控制電壓的大小可以調節輸出功率,通過檢波的輸出電壓信號可實現反射功率的
  8. Acoustics - hearing protectors part 1 : subjective method for the measurement of sound attenuation

    聲學護聽第1部分:聲的主觀方法
  9. Acoustics. hearing protectors. part 1 : subjective method for the measurement of sound attenuation

    聲學.聽力保護.第1部分:聲音的主觀方法
  10. Test method for measuring the package attenuation coefficient of a sealed device for radioisotope hermetic test

    放射性同位素密封試驗用封裝件封殼系數的方法
  11. The attenuators and the sensitivity of detectors are calibrated in varied frequencies. the attenuation of the cable is also calibrated

    對晶體檢波在不同頻率下的礦靈敏度進行了定;對同軸信號線的瓣行了標定。
  12. It is based on the principle : under a number of angles, the x - ray attenuation in a cross section of a human body is measured by detector resulting in a set of profiles. this set of profiles is called the radon transform of the object in mathematics. the problem now is to reconstruct a two - dimensional image via inverting its radon transform

    它所基於的成像原理是:人體的某個剖面在若干個角度上被x射線束照射,照射后x射線的被檢記錄下來,形成投影集合,數學上將這個投影集合描述為該剖面的radon變換,通過反演radon變換就能夠重建剖面的二維圖像。
  13. Computerized tomography ( ct ) is a typical non - invasive examination techniques in medicine, which can depict anatomical structures without damaging the human body. lt is based on the principle : under a number of angles, the x - ray attenuation in a cross section of a human body is measured by detector resulting in a set of profiles. this set of profiles is called the radon transfoim of the object in mathematics. the problem now is to reconstruct a two - dimensional image via inverting its radon transform

    它所基於的成像原理是:人體的某個剖面在若干個角度上被x射線束照射,照射后x射線的被檢記錄下來,形成投影集合,數學上將這個投影集合描述為該剖面的radon變換,通過反演radon變換就能夠重建剖面的二維圖像。
  14. The experimental study is performed on the c - band tapered milo designed with the help of the simulation. the whole system is calibrated separately by parts. from milo to microwave receiving hom, the special system is simplified to be a two - port network and its s parameter is measured to calculate the attenuation factor a

    對于微波功率的標定問題,我們根掘實驗條件,將整個系統劃分為幾個部分分別進行了標定,包括:從milo到接收喇叭組成的特定系統,將該特定系統簡化為一雙口網路,並出了其s參數,從而計算出與頻率密切相關的a ;對固定在不同微波頻率下的進行了標定。
  15. At the same time, the power capacity of the above mentioned antenna is preliminarily analyzed. the results show that in the pass band, their power capacities increase with the frequency on the whole, ranging from 10 ’ s kw to 100 ’ s kw. with the change of the pulse duration of microwaves, the measurement is carried out on the sensitivity of the detectors of the types wb - cd01 and 2087 - 6001 - 00, on the attenuation of the

    通過調整微波脈寬,對wb - cd01型、 2087 - 6001 - 00型等檢波的靈敏度,對2082 - 4137系列和tts系列,對rg - 142型微波電纜的進行了實驗定,結果表明:在微波脈寬大於40ns時,檢波靈敏度基本無變化;當微波脈寬在20 ~ 40ns時,檢波靈敏度會有一定變化,變化趨勢和程度與檢波的型號有關;而上述型號的和微波電纜的幾乎不受微波脈寬的影響。
  16. Methods for measuring the real - ear attenuation of hearing protectors

    聽力保護的真耳聽覺方法
  17. Test method for measuring shock - attenuation characteristics of natural playing surface systems using lightweight portable apparatus

    利用輕便式儀立體聲播放系統震動特性的方法
  18. Fibre optic interconnecting devices and passive components - basic test and measurement procedures - examinations and measurements - accuracy and repeatability of the attenuation settings of a variable attenuator

    光纖互聯裝置和無源部件.基本試驗和程序.第3 - 14部分:檢查和.不同裝置的準確性和可重復性
  19. Fibre optic interconnecting devices and passive components - basic test and measurement procedures - part 3 - 14 : examinations and measurements - accuracy and repeatability of the attenuation settings of a variable attenuator

    光纖互聯裝置和無源部件.基本試驗和步驟.第3 - 14部分:檢查和.不同的裝置的準確性和可重復性
  20. Cable assemblies, cables, connectors and passive microwave components - screening attenuation measurement by the reverberation chamber method

    電纜組件電纜連接和無源微波元件.用混響室法濾屏
分享友人