補償調節器 的英文怎麼說
中文拼音 [bǔchángdiàojiéqì]
補償調節器
英文
compensated regulator- 補 : Ⅰ動詞1 (修理; 修補) repair; mend; patch 2 (補充; 補足;填補) fill up; add supplement; supply; ...
- 償 : 動詞1. (歸還; 抵補) repay; compensate for 2. (滿足) meet; fulfil
- 調 : Ⅰ動詞1 (配合得均勻合適) harmonize; suit well; fit in perfectly 2 (使配合得均勻合適) mix; adju...
- 節 : 節構詞成分。
- 器 : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
- 補償 : compensate; make up; make up for; make it up to sb. ; make sth. good; compensation; offset
- 調節器 : regulator; adjuster; governor; controller; conditioner; actuator; phaser
- 調節 : regulate; adjust; monitor; measure; take care of; condition; regulation; adjustment; conditioning...
-
Set the shutter by pressing and holding the exposure - compensation button, which also bears a small time value ( tv ) label, and turn the up / down dial until the desired speed, in numeric half steps, appears in the viewfinder or lcd
按住曝光補償鍵+ / - ,它也肩負著tv功能,調節主控撥盤直到需要的速度,速度以1 / 2級調節並在取景器或lcd屏中出現。In the digital inverter, we adopt the technology of digital dynamic waveform correction, which can compensate the delay between control signal and output waveform, and ensure the accuracy of control. at the same time, the technology of digital dc component adjustment was introduced, by which we can exactly compensate the control signal, and realize adjusting dc component of output on the premise of output performance
在基於dsp的數字變換器平臺中,採用全數字波形校正技術,完全補償了控制信號延時、功率管開關延時以及死區時間對輸出spwm波形所產生的畸變,充分保障了變換器控制的準確性;採用數字直流分量調節技術,可以精確地對控制信號進行補償,在充分保證輸出性能的前提下,實現了輸出直流分量的調節。By regulating the compensation current injecting into the compensation winding of the reactor, the reactor inductance at different harmonic frequencies can be independently and continuously adjusted
有源電抗器由一對耦合繞組和一個補償電流發生器組成,通過控制有源電抗器補償繞組中的諧波磁通補償電流,可以獨立且連續地調節電抗器在不同諧波頻率下的電感量。The second chapter simply introduces the development of alternate asynchronous inverter technology and retrospects some types of energy - saving systems for hydraulic elevators. then the working principles of the project are discussed and analyzed at four different working status, i. e. light load upwards, heavy load upwards, light load downwards and heavy load downwards. and the chapter focus on the introduction of structure design of pump station, calculation and type selection of pump / motor reversible units, research on oil leakage principles of accumulator circuit, design of accumulator - pump / motor pressure - energy transformer and integrated valve blocks, etc. the last but not the least, the electrical wiring of vector inverter control cabin and design of computer control and data acquisition system are introduced
論文第二章首先簡單介紹了交流異步電動機變頻調速技術的發展概況,在回顧電梯液壓控制系統節能技術的基礎上,介紹了本課題研製的「採用蓄能器的液壓電梯變頻節能控制系統研究」的基本原理,分析了動力系統在電梯轎廂輕載上下行、重載上下行等四種典型工況下的基本工作狀態和工作方式;詳細地介紹了本課題節能系統液壓動力泵站的結構設計和參數設計,重點研究了液壓動力泵站的結構設計、液壓泵馬達可逆性問題及其選型設計計算、蓄能器迴路泄漏油損失機理的研究及其補償裝置的設計、蓄能器-泵馬達壓力能量轉換裝置的設計、多功能集成控制閥組的設計等內容;最後簡單介紹了本課題矢量控制變頻控制櫃的外部附件電氣接線、計算機控制及數據採集系統的硬體設計等內容。On account of the disadvantages of the feedback reactive power compensator, a device of its simplified scheme is studied in this paper, in which the reactive power is adjusted by regulating the voltage of the low - voltage side of the transformer
由於這種反饋式補償方案存在一些問題,本文分析了它的簡化形式,即通過調節降壓變壓器低壓側的母線電壓來調節濾波器的無功出力的補償方案。In this paper, a new control strategy based on the adaptive deadbeat voltage space vector is presented. this control scheme has a lower sample frequency and a smaller difference between switch frequency and sample frequency. it has many advantages, such as producing zero vectors organically, tracing exactly, non - shaking, etc. and its dynamic response is better
對于電能質量調節器來講, pwm跟隨指令參考信號的控制性能在很大程度上影響著裝置的補償效果,本文選擇無差拍電壓空間矢量控制為系統控制策略,這種控制方法具有采樣頻率低,開關頻率與采樣頻率的差距小,能有機地產主零矢量、跟蹤精確以及無抖振等優點,動態響應快。Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor
本研究通過分析所獲得的最優綜合控制組合曲線及電網潮流,總結出了如下規則:隴南電網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償電抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內無功潮流分佈合理、各變電站母線電壓在理想的范圍內時電網有功損耗最小,從而也提高了電網安全運行水平及供電質量。With the consideration of most of our transformers " taps are changed manually and some fluctuate unnecessarily, this paper presents a supervision system of oltc based on plc control technique. then we combine this system with reactive power compensate device such as shunt capacitor to design a new supervision system of substation voltage and reactive power synthetic control based on plc fieldbus
針對國內變電站電壓調整大多依靠人工調節,且有載調壓變壓器( oltc )分接頭動作頻繁的特點,本文提出了基於plc控制技術的有載調壓監控系統的研製方法,並以此監控系統為基礎,結合併聯補償電容器組等無功補償設備,設計了一種基於plc現場總線的變電站電壓無功監控系統。The mrafc scheme employs a reference model to provide closed - loop performance feedback for generating or modifying a fuzzy controller ' s knowledge base. the adaptive compensation term of optimal approximation error is adopted. by theoretical analysis, the closed - loop fuzzy control system is proved to be globally stable, with tracking error converging to zero
該方案利用參考模型作為閉環系統的反饋信號來產生、調節模糊控制器的規則庫,並通過引入最優逼近誤差的自適應補償項來消除建模誤差的影響,不但能保證閉環系統穩定,而且可使跟蹤誤差收斂到零。Psg pressure compensated simple governor
帶壓力補償的簡易調節器Two generating methods of compensation current are also proposed for the purpose of eliminating detuning or limiting harmonic voltage contents, in which the compensation current is the weighted superposition of filter harmonic currents or voltages and the regulating factor
針對消除失諧或限制諧波電壓含量的不同控制目標,提出了諧波磁通補償電流的兩種生成方法,補償電流分別是濾波器電流或母線電壓中各次諧波分量與調節系數的加權合成。The reactive power optimization compensation is to find the suitable compensation place and the best compensation capacitance by adjusting the generator bus voltages, transform taps and reactive compensation capacities in the condition of satisfying power load requirement, which can guarantee the secure and high quality power for consumers. the improved genetic algorithm is applied in this thesis according to the features of reactive power optimization of high voltage transmission bus, which are the non - linear problems with multi - variables and multi - restrictions
電網無功優化補償是在有功潮流調度給定的情況下,以負荷節點電壓和線路輸送無功功率作為狀態變量,運用優化演算法,調節發電機節點電壓、變壓器可調分接頭和無功補償裝置,在滿足電力負荷的要求下,尋求合理的無功補償點和最佳補償容量,保證電網能夠安全、優質地向用戶供電。The electric power harmonic comprehensive control system with low cast and high security is applied in this article. it adopts that sourced compensation links with non - sourced compensation herewhich the former is realized by high frequency pwm control technology and the latter is carried out by crystal switch formed by non - flow and over - voltage. it can realize stepless modulation with imaginary power, mightiness compensation of harmonic and negative electricity, and circuitry consumption debasing are achieved
提出採用有源補償與無源補償相結合的電力諧波綜合治理技術及裝置,無源部分採用無涌流和過電壓的晶閘管控制電容器技術實現,有源部分採用高頻pwm控制技術實現,成本低、可靠性高、可實現無功功率的無級調節、強力補償諧波電流和負序電流,降低線路損耗。In order to ensure the whole system operate economically, power department equip transformer with onload tap changer and shunt capacitors for most distribution substations, according to the operating condition, adjusting the position of transformer taps and capacitors can control the variation of voltage and reactive power exchanger of distribution substations and power system in certain extent
為確保整個系統運行經濟性,降低網損,電力部門在大多數變電站配置了有載調壓變壓器和並聯補償電容器組,根據運行情況適當調節變壓器分接頭的位置和投切並聯補償電容器組,可以降低電壓變化和變電站與系統的無功交換控制在一定的范圍內,確保供電質量和電網運行的經濟性。Abstract : this paper developed time domain integral constraints on error response for siso feedback control systems caused by nominal plant ' s near cancellation of stable pole - zero near the j - axis. these integral constraints should be satisfied by any feedback control systems. these integral constraints give new insight into the inherent trade - offs. it will result in the settling time longer or the infinite norm of the error response larger when there are near cancellations of stable pole - zero near the j - axis. hence, when feedback control systems are designed, it is necessary to avoid the compensator ' s poles and zeros nearly cancelling the nominal ' s zeros and poles ( even if these poles and zeros are stable )
文摘:導出了單輸入單輸出反饋控制系統誤差響應基於名義系統穩定的零、極點近似相消的時間域積分約束,此積分約束是任何反饋控制系統均應滿足的.這一約束給出了單輸入單輸出反饋系統固有折中的新的觀點.名義系統穩定的零、極點近似相消的存在導致反饋控制系統的調節時間延長或者誤差響應的無窮范數變大.因此,在反饋控制系統設計中,盡量避免補償器的零、極點與名義系統的極、零點近似相消(即使這些零、極點是穩定的)Finally, the rules used to design the induction motor and set the inverter v / f curve are summarized to improve the stability of the system movement in the forth part of the dissertation, three measures are brought forward to eliminate the system low frequency oscillation. the first measure adopts pulse based dead time compensation to suppress the oscillation. as second measure, considering the motor and inverter as an integration, the discontinuous space vector modulated strategy named dpwm3 is proposed for the first time to suppress the oscillation
措施一是在總結常用死區補償方法的基礎上,提出脈沖為基礎的死區時間補償法( pbdtc )對死沈陽工業大學博士學位論文區進行補償,抑制系統的低頻振蕩;措施二是從逆變器與電機的機電一體化配合更加完善的角度,首次提出採用不連續空間矢量調制策略dpwm抑制系統的低頻振蕩;措施三是通過對系統中電機參數的調節,達到抑制系統低頻振蕩的目的;最後進行了實驗驗證。Making use of the idea of the parallel genetic algorithms, presenting the adaptive multiple subpopulation evolutive strategy. presenting extinction and immigration strategy in order to avoid the similar or even same individuals appear. in order to enhance convergence velocity of reactive power optimization of the radial distribution system, combining the characteristic of the radial distribution system, a sensitivity analysis approach was build up for optimal selection of capacitors and mutation of transformer tap changer
為了提高配電網無功優化的收斂速度,結合配電網的特點,提出採用簡單可行的靈敏度公式選擇無功電容補償器的安裝地點,並用靈敏度分析變異變壓器分接頭,使變異運算元的選取更符合配電網無功優化問題中關于調節變壓器分接頭的實際情況,減少了一些不必要的變異運算,使適應性和魯棒性加強;根據實際情況採用無功補償電容器的啟發式變異,使變異運算元的選取更符合無功優化問題中關于補償電容器的實際。According to the characteristic of nine - area diagram of substation vol / var coordinated control, this system gives the defination of fuzzy sets and the degree of membership of input / output variables, and designs corresponding control rules. the results of simulation demonstrate the system can satisfy the constrains of the day - adjusting times of the switching of on - load transformer and paralleled compensation capacitors, and ensure voltage quality, reactive power basical balance. considering the var requirement in different load time period and the control demand in load saltation, a improved control scheme is provided. the results of simulation show the improved scheme can meet the demand of vol / var in different load time period, protect the wrong operation when either voltage or reactive power appears saltation, and decrease the times of regulation of the switching of on - load transformer and paralleled compensation capacitors finally, a background software module of substation vol / var coordinated control is designed, based on the supervisory control and data acquisition system of substation
模擬結果證明該系統能在各種負荷條件下確保電壓合格和無功基本平衡,且能滿足變電站對有載調壓變壓器分接頭日調節次數和並聯補償電容器組的日投切次數的限制。通過考慮不同負荷時段對無功功率的需求和負荷突變情況下的控制要求,對上述模糊控制策略進行了改進,模擬結果證明改進后的控制策略能滿足不同負荷時段對電壓和無功的要求、抑制電壓或無功突變情況下的誤動作,且有效地減少了有載調壓變壓器分接頭和並聯補償電容器組的調節次數。最後基於變電站scada系統設計了一后臺電壓無功綜合控制軟體模塊。Firstly, we introduced usages and developing situations of analog integrated circuits and the different design skills between analog and digital circuirs. this article secondly makes a detailed analysis and expatiation for the operational principle and design technique of regulator. then realize the regulator design in two different ways ( stable rc network and variable rc network ), and accomplish the simulation using mxic 0. 35m process by hspice
本文首先對包括電壓調節器在內的模擬集成電路的特點、作用和發展概況以及它們與數字集成電路在設計方法上的差異等作了概述,然後在對電壓調節器的工作原理及設計方法進行系統的闡述和分析的基礎上,設計了兩種不同結構形式的可以為存儲器晶元提供工作電源的電壓調節器(採用固定rc補償網路的電壓調節器與採用可變rc補償網路的電壓調節器) ,在mxic0 . 35 m的cmos工藝條件下,用hspice進行了模擬與測試。The paper presents a new e. a. f ( electric arc furnace ) adaptive control method based on a neural network ' s compensation by predicting. the neural network is used here to predict the condition of e. a. f, then to control an actual system by compensating the outputing of routine controller. the dynamic modification of the weighting value of a neural network by improved dbd algorithm serves as an adaptive method. hence the system can adapt itself better to the variations in load and external interference. which has yielded a satisfied control quality
電極調節器採用一種新的電弧爐電極自適應控制方法- - -基於神經網路預估補償的自適應控制。採用神經網路預估對象狀態,進而對常規控制器的輸出做補償以控制實際對象,利用改進的dbd演算法動態修改神經網路權值作為自適應方法,使系統較好地適應負荷和外擾的變化,從而獲得滿意的控制質量。分享友人