  1. The way of taking one nth out of capacitor ' s the first harmonic capacitive reactance as its nth harmonic impedance is verified whit the data from tang7c. according to the approximately estimating method, the first harmonic impedance of 220kv system is calculated. on the basis of the models, this paper gives the harmonic equivalent circuit of substation and gives the b ( n ) function of the harmonic time n. when the capacitors has different combination, b ( n ) ' s value will also change, with the inputting local measurement data, the paper studies the series and parallel resonance at the substation, and deduces that the reason the capacitor ' s fuse of tang6c is frequently interrupted is that its capacitor current contains a large number of 5th harmonics, and that the reason the discharging pt of tang7c capacitor being exploded is also that the 7th and 9th harmonic currents are amplified

    據此,對該站進行了串聯諧振分析和並聯諧振分析,並結合測試數據和有關變電站的運行,指出了導致該站電容湯6c頻繁燒保險的主要原因是5次諧波電流含量偏高,引起湯7c放電pt爆炸也是因為7次和9次諧波電流被放大。針對這些導致湯陰變電站電容故障的原因,提出了相應的諧波治理措施,包括針對湯6c電容5次諧波電流含量偏高的原因,提出了停運湯6c電容或者通過把湯sc電容的部分容量併入湯6c電容(湯sc其餘部分停運)以增加湯6c諧波承受能力的措施;針對# 2變低壓側7次和9次諧波電流被放大的現象,提出了在湯7c電容上加裝一定百分比的串聯電抗的措施。
  2. Using fourier transformation computational method, the fir filter was designed. the acceleration signal dynamic error was revised through the fft 、 ifft and frequency correction in the operating frequency scope. the signal processing had been realized on dsp, and the signal data was really recorded

    應用傅里葉變換的計算方法,並且完成了fir濾波的設計,通過傅里葉正反變換和頻率實現工作頻率范圍內加速度信號動態誤差修正,在dsp上實現了信號處理,真實地了信號數據。
  3. A new model about measuring harmonics on - line is proposed in this paper. after band pass filtering, sampling storage and the monitoring on - line with artificial neural network ( ann ), we can obtain the harmonics signal, which is used to compensate harmonics. using the basic principle of analog parallel harmonics measurement and a special multi - layer feedforward neural network, a corresponding harmonics measurement on - line is built

    在本文中提出了一種新型電網諧波監測系統模型,通過帶通濾波,采樣存儲以及神經網路組成的監測系統可以實時監測電網諧波,當電網中的3次、 5次、 7次諧波超過容許值時,給出控制信號啟動以諧波,並可以控制諧波,最終達到監督電網,抑制諧波、減小諧波的目的。
  4. Notifies the compensating resource manager compensator of the commit phase of the transaction completion and the upcoming delivery of records

    通知資源管理( crm )事務完成的提交階段,並且通知即將傳遞
  5. Notifies the compensating resource manager compensator that it has delivered all the log records available during the commit phase

    Compensator . endcommit方法通知資源管理crm在提交階段期間已傳遞所有可用日誌
  6. The analyzer has the abilities of long - term online operating, real - time measuring and analyzing, managing of history data, etc. compared with the traditional analyzer, it has many advantages, such as easy controlling, strong processing and graphics output, etc. it is able to record the abundant and integrated data for the electric department, and provide the reference for selecting correct compensation technology. in this paper, some key technologies are discussed and analyzed

    它實現了可長期在線運行,實時測量分析,歷史數據管理等功能;與傳統的儀相比,具有操作簡單,處理能力強,圖形輸出等優點;可為電力的生產、運行和管理部門提供豐富、完整的實測資料,也為電力技術工作者選用方式、裝置和技術提供了重要依據。