負荷選擇器 的英文怎麼說

中文拼音 [xuǎnzhái]
負荷選擇器 英文
job selector dial
  • : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
  • : 荷名詞(蓮) lotus
  • : Ⅰ動詞1. (挑選) select; choose; pick 2. (選舉) elect Ⅱ名詞(挑選出來編在一起的作品) selections; anthology
  • : 擇動詞(挑選) select; pick; choose
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 負荷 : [電學] load; charge; weight
  • 選擇 : select; choose; opt; election; choice; culling; alternative
  1. Long - hole and geometrical proportion type of mixing unit is finally adapted in lpg supply system, and power and torque output of lpg engine are improved by increasing compression ratio, and ignition characteristic is tried to adjusted to satisfy engine performance. meantime emission performance and noise level of lpg engine at full - throttle and other various part - throttle operations are tested and compared with former gasoline engine. ( 3 ) it is verified by engine dyno tests that lpg engine has better synthesized performance at aspects of power and torque, fuel economy, as well as emission than former gasoline engine

    了等比例長孔式混合控制空燃比;通過提高壓縮比來彌補動力性的損失;以動力性為主控目標,對最大功率點、最大扭矩點、中等轉速、最低轉速點所對應的發動機轉速做了點火特性的調節;通過空燃比的合理控制,直接改善發動機的動力性、經濟和排放指標;作為對缸內燃燒過程的理論分析,進行了燃燒特性的實驗測試;對原汽油機和新開發的液化石油氣發動機,進行了外特性和部分特性以及怠速的排放及噪聲對比性測試。
  2. The chosen controlled parameter must be single function of extraventricular temperature because extraventricular temperature affect immediately radiator ' s emitting heat, heat net supplying heat and user ' s heat load. but the sometime chosen controlled parameters all are ' t extraventricular temperature ' s single function

    室外溫度的變化直接影響用戶熱、散熱散熱量、熱網供熱量的大小,所以的被控參數應與室外溫度有單值函數關系,而以往所的被控參數與室外溫度之間都不是單值函數關系。
  3. The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,

    基於基爾霍夫定律的電流差動保護無論對於何種形式的輸電線路都是一種簡單、可靠、性強的保護形式,電力系統的發展使得電流差動保護應用於線路保護成為需要,而電子、通信技術的發展使得電流差動保護應用於輸電線路成為可能。首先,本文對目前線路保護的研究和實際應用情況進行了討論和分析,比較了常用線路縱聯保護的實現原理和實現條件及優缺點。其次,針對常規相量電流差動保護易受正常電流和故障過渡電阻影響的缺點,同時為加快差動保護的動作速度,對基於故障分量瞬時采樣值電流差動保護的原理、判據、動作特性等作了討論和分析,結果表明基於故障分量瞬時采樣值電流差動保護在可靠性、靈敏度、抗電流互感飽和方面明顯優于常規相量電流差動保護,對電流差動保護各端的同步采樣方法和數據通信也進行了分析和評價。
  4. The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method

    本論文從目前空調工程中使用的變流量水系統入手,研究了盤管換熱在部分下水流量與換熱量的非線性關系,分析了文獻中介紹的旁通管通流能力的不足之處和一次泵水系統採用壓差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次泵變流量水系統中壓差旁通控製法、回水溫度控製法、控製法的精確性,並得出了在一次泵水系統的工況轉換時,採用控製法能使冷水機組及其相應水泵在啟停時的變化范圍較小,更符合建築物的冷量需求,節能效果較好的結論。
  5. The autor thought that for the main transformer, the load rate should be increased above 85 % ; and for the distributor transformers set with the electrial room, according to efficiency first principle, the load rate should be control at 40 % ~ 60 %

    作者認為:主變壓設計時,應考慮提高其率達85 %以上;電氣室配電變壓時,應按效率優先原則為主,其率控制在40 % ~ 60 %之間。
  6. Under different load, when we apply this software to any time, region and cooling way, we can get the hottest spot increment and aging rating. to manufactory, the software means sounder thermal design, which will meet the load, putted forward by user, while to user, the software equal to a master who can help them decide the capacity rating of the transformer, which will fit the load. by using the software, the potential danger and the waste, caused by unfit load choice may be avoided

    研究開發了計算乾式電力變壓載能力的計算軟體,可對于各種絕緣結構,各種冷卻方式和任一地區、任一時間下運行的變壓在不同運行載下的最熱點溫升絕緣老化率進行分析和計算,同時利用該軟體製造廠可以依據用戶提出的運行載量給出相應的熱設計方案,用戶可根據運行載情況利用軟體計算所需變壓的額定容量,避免額定容量不當造成隱患和浪費。
  7. Based on the specification, the right phase control thyristor is chosen and the series number of thyristor is calculated. the paper also calculates the power loss of thyristor under the pulsing load, choosing the heat sink and forecast the temperature rising

    以此為基礎,合理了所用的高壓晶閘管元件,計算了所需元件的串聯個數,對類似於脈沖下的晶閘管耗散功率進行了計算,並了元件的散熱,預計了元件的溫升。
  8. Second, the model for evaporator is founded based on traditional theory, including refrigerant side and air side, and the method for choosing element ; the calculation for the load of refrigeratory ; the thickness choice for heat insulation material ; the work area of evaporator is conformed ; and the matching for the other elements

    2 )根據傳統理論建立了蒸發的數學模型,包括冷劑側和空氣側的數學模型、微元的取;冷庫冷的計算和確定;隔熱材料合理厚度的;蒸發工作面積的確定;以及其他製冷元件的匹配理論。
  9. This paper proposes a client - centered load distribution mechanism which is different from the conventional algorithm of selecting dynamic replica servers

    本文提出了與傳統的動態復制服務演算法不同的以客戶為中心的分佈( client - centeredloaddistribution , c ~ 2ld )機制。
  10. Transformers and reactors ; guide to selection and application of on - load tap - changers

    變壓和電抗.帶分接開關的和應用指南
  11. This paper introduces the geneses of the sludge bulking and the operation mechanism of bio - selector, advances a simple and easy design method of flocculation burden, and expounds the design method of the bio - selector

    簡要介紹了污泥膨脹的成因和生物的工作機理,提出了一種簡便易行的絮體設計方法,並論述了生物的設計方法。
  12. In the application of driving white led, an auto - adjustable charge pump which adjust work mode according to the forward voltage of load led and input voltage is presented. the conventional charge pump changes work mode at fixed input voltage value

    在電泵驅動白光led的應用中,本論文研究設計了一種根據載led正向導通壓降和輸入電壓來泵工作模式的電泵型led驅動
分享友人