負荷電阻 的英文怎麼說

中文拼音 [diàn]
負荷電阻 英文
load resistance
  • : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
  • : 荷名詞(蓮) lotus
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • 負荷 : [電學] load; charge; weight
  • 電阻 : (物質阻礙電流通過的性質) resistance; electric resistance (電路中兩點間在一定壓力下決定電流強度...
  1. Engine load simulated control system was consisted of two unattached parts of work resistance simulated control subsystem and electric bow wave dynamometer control subsystem. with the mathematic models of engine load simulation controller, which transferred the work resistance ' s change to engine load change immediately, the system can met the need of the simulation control system

    發動機模擬加載控制系統包括彼此獨立的作業力模擬控制子系統和渦流測功機控制子系統兩部分,應用發動機模擬控制器數學模型,使作業力的變化及時轉換為發動機的變化,能夠滿足模擬系統的控制要求。
  2. This paper discusses the ability of avoiding maximal power flow of quadrilateral impedance relay and round impedance relay in detail and puts forward the setting principle and setting method of load limiting resistor of backup distance protection

    本文對四邊形和方向圓特性抗繼器躲線路最大潮流的能力進行了詳細分析,提出了距離保護限制的整定原則和整定方法。
  3. The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,

    基於基爾霍夫定律的流差動保護無論對於何種形式的輸線路都是一種簡單、可靠、選擇性強的保護形式,力系統的發展使得流差動保護應用於線路保護成為需要,而子、通信技術的發展使得流差動保護應用於輸線路成為可能。首先,本文對目前線路保護的研究和實際應用情況進行了討論和分析,比較了常用線路縱聯保護的實現原理和實現條件及優缺點。其次,針對常規相量流差動保護易受正常流和故障過渡影響的缺點,同時為加快差動保護的動作速度,對基於故障分量瞬時采樣值流差動保護的原理、判據、動作特性等作了討論和分析,結果表明基於故障分量瞬時采樣值流差動保護在可靠性、靈敏度、抗流互感器飽和方面明顯優于常規相量流差動保護,對流差動保護各端的同步采樣方法和數據通信也進行了分析和評價。
  4. The electric heat components and heated components in resistor furnace were regarded as research object, the simplified model was provided on the basis of simplification of studied objects, the thermotechnical theoretical calculation and analysis for it were done by utilizing radiation heat transfer theory, some main factors influencing the temperature of electric heat component were obtained on condition that the hot load for the heated component be constant, thermotechnical engineering scheme by which the service life for resistor component could be prolonged, was raised

    摘要以爐中的熱元件和被加熱元件為研究對象,經過簡化提出簡化模型,運用輻射換熱理論對其進行了熱工方面的理論計算和分析,在被加熱元件熱一定的情況下,得出了影響熱元件溫度的幾大要點,提出了延長熱元件使用壽命的熱工技術方案。
  5. It also could clog railway lines and ports and trigger brown - outs as overloaded power grids collapse

    投資過熱還可能導致鐵路和港口塞,使超運轉的網陷入癱瘓,從而引發大面積斷
  6. The pt secondary loop voltage drop is a changing amount and has the characteristics of indirection and certain randomness. the second, according to the cause of pt secondary loop voltage drop, the different methods to reduce the pt secondary loop voltage drop were analyzed and the conclusions are draw as below : 1. changing bigger section wire and maintaining the connector plugs regularly can reduce the pt secondary loop voltage drop effectively, but ca n ' t guarantee which meets the relevant rules

    首先,通過對壓互感器二次壓降的形成機理進行分析,得出以下關於二次壓降的相關結論: 1 、壓互感器二次壓降等於二次迴路抗和迴路流的乘積; 2 、壓互感器二次迴路抗分為元器件自身抗和接觸抗兩部分,且接觸抗佔主要部分,從而使得壓互感器二次迴路抗具有動態特性,而且具有一定的隨機性; 3 、壓互感器二次迴路流與二次和迴路抗大小相關,因而二次迴路流也是變化的; 4 、壓互感器二次壓降是一個變化量,且具有單向性和一定的隨機性。
  7. Engine load simulated control system was consisted of two unattached parts of work resistance simulated control subsystem and electric eddycurrent dynamometer control subsystem

    發動機模擬加載控制系統包括彼此獨立的作業力模擬控制子系統和渦流測功機控制子系統兩部分。
  8. As a result, this paper gives a corresponding harmonic prevent me asure. finally, according to the asymmetrical characteristics of electrical traction loads, this paper studies the negative sequence currents under different loads and makes a piece of advice for reducing the negative sequence currents produced

    最後,還根據力牽引三相不對稱的特點,分析了抗匹配平衡變壓器在不同條件下的流,對如何減小力牽引流提出了一點建議。
  9. In the deregulated power market , the power grid operator is facing many uncertainty and risks risk concept , risk analysis approach and risk management are introduced in chapter ii , the maj or risks of grid operators is analyzed and evaluated in details based on the real situation and data of yueyang city, hunan province , the economic risk resulting from the uncertainty of load prediction of whole system , generation capacity and parallel quantity of the large enterprises self - owned power plant are analyzed meanwhile , the increase of large enterprises self - owned power plant may cause economic and security risks considering different risk , the qualitmive and quantitative approaches are respectively adopted the direct and indirect congestion risks are evaluated based on probabilistic theory and decision theory the retail pricing and trade modes are major areas embracing risks as well chapter iii divides the risks in internal and external ones based on the characteristics of risk and put forward the layered risk management approach

    詳細分析和論述了網經營企業面臨的各種風險。基於湖南省岳陽地區力市場的實際情況和多年歷史數據,採用定性分析和定量計算的手段具體分析了、自備廠發量和上網量預測不確定性以及自備廠的大量增加給網企業帶來的經濟性風險和安全性風險。無論是長期還是短期,塞不僅會對網造成直接風險,還可能造成間接風險。
  10. The basic software consists of topology analysis, on - line load flow computation, state estimator, security analysis, dispatchers training simulator, short circuit current computation, and voltage / reactive power optimize, etc. the derived softwares consist of load control, capacitor optimizer configuration, transformer and feeder load distribution, impedance computation of generator, etc. network analysis software is powerful dispatch tool, though witch the current state of the power system can be realize, then improve the security and economic potential

    Dms網路分析的基本軟體有:網路結線分析、潮流計算、狀態估計、預報、短路流計算、壓無功優化等。派生軟體有:控制、容器優化配置、變壓器與饋線分配、抗計算等。網路分析軟體是有力的調度工具,通過它可以了解和掌握當前的運行狀態,從而挖掘安全和經濟方面的巨大潛力。
  11. The influences of several factors such as harmonics, intermittent arc grounding, ct, load and fault resistance have been thoroughly analyzed, therefore, it is fundamental work for its application

    深入細致地分析了諧波、間歇弧、流互感器、、過渡等多個因素對故障選線結果的影響,為方案的實用化奠定了基礎。
  12. By adopting resistance divider, voltage sensor designed in this topic has no ferromagnetic resonance, overcome saturation, has no load sharing, and is permitted to short and cutoff in circuit, so it has high reliability

    本課題所研究的壓傳感器採用分壓器原理,不存在鐵磁諧振,克服了鐵心飽和,不再有分擔,短路和開路都是允許的,具有高的可靠性。
  13. 30 mhz measurement of quartz crystal unit parameters by zero phase technique in a pi - network - part 4 : method for the measurement of the load resonance frequency fl, load resonance resistance rl and the calculation of other derived values of quartz crystal units, up to 30 mhz

    用型網路的零相位法測量石英晶體元件參數.第4部分:石英晶體單元諧振頻率fl諧振rl的測量方法及其他石英晶體元件導出值的計算方法
  14. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷路器所造成的事故無論是在次數,還是在事故所造成的停時間上都占據總量60以上。因此,及時了解斷路器的工作狀態對提高供可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷路器機械特性參數監測方法;提出了二次迴路保護器的概念,並將跳、合閘線圈完整性監視和二次迴路保護結合起來,給出具有完整性監視功能的二次迴路保護器實現方案;根據斷路器生產廠家提供的斷路器額定短路流分斷次數,計算每次分閘對應的觸頭壽命損耗,預測觸頭壽命;提出根據斷路器殼體溫度和斷路器周圍空氣溫度結合斷路器熱來計算斷路器主觸頭穩態溫升的方法,並根據此時的流間接計算主觸頭迴路的;在硬體路設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作壓晶元之間的介面問題,並給出了直接聯接的接線方案。
  15. The shortcoming of using voltage and power to describe the voltage critical state is analyzed and the load impedance angle is introduced for the critical point of voltage. the ternary analysis method of voltage v, power p and load impedance angle is established

    本文首先分析了採用壓和功率描述壓臨界狀態的不足,提出了引入抗角的三個參數來描述壓臨界狀態,即壓v 、功率p和抗角的三元分析法。
  16. Because the harmonics in tangyin substation are primarily from electric traction loads, this paper gives the structures of several main locomotive models and general harmonics they produce. the harmonics produced by electric locomotive have a characteristic that their range and phase are both dispersive. this paper also analyzes the impedance - matching balance transformer ' s structure and harmonics injected into the power system at its primary side, and sums up the characteristics of the harmonics from electric traction loads in the tangyin traction substation

    鑒于湯陰變站的諧波主要來自力牽引,本文列舉了力機車幾種主要車型的結構以及它們產生諧波的概況,得出了力機車的各次諧波流幅值和相角具有較大分散性的特點。針對湯陰牽引變站的牽引變壓器,分析了抗匹配平衡變壓器的結構及其高壓側注入網的諧波,推導了有關計算公式。通過理論分析並結合湯牽線的實測諧波數據,歸納了力牽引注入湯陰變站的諧波的特點。
  17. Some fundamentally influential factors such as systemic structure, the distribution of power flow, effects of excitation system and pss, as well as characteristics of load models, etc, are discussed in detail to study the systemic damping

    隨后從系統結構、潮流分配方式、勵磁系統和力系統穩定器的作用以及特性等角度,詳細討論了影響互聯系統振蕩模式尼的因素,並研究了這些因素的相互作用。
  18. Model and algorithm of transmission congestion management based on interruptible load

    可中斷參與輸塞管理的模型與演算法
  19. 4. simulation and comparisons of the dynamic voltage stability of constant impedance load, constant current load and constant power load in the context of large disturbances, and analyses of the simulation results with their load characteristics

    4 .對大擾動下恆抗,恆流,恆功率的動態壓穩定性進行了模擬比較,並運用其特性對模擬結果進行了分析。
  20. 30mhz measurement of quartz crystal unit parameters by zero phase technique in a - network ; part 4 : method for the measurement of the load resonance frequency fl load resonance resistance rl and the calculation of other derived values of quartz crystal units, up to 30 mhz

    用型網路的零相位技術測量石英諧振器參數.第4部分:石英晶體元件諧振頻率fl諧振rl的測量方法,以及石英晶體元件其他導出值的計算方法