負阻抗電路 的英文怎麼說

中文拼音 [kàngdiàn]
負阻抗電路 英文
negative impedance circuit
  • : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • : Ⅰ動詞1 (抵抗; 抵擋) resist; combat; fight 2 (拒絕; 抗拒) refuse; defy 3 (對等) contend with...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • 阻抗 : [電學] impedance
  • 電路 : [訊] circuit (ckt); electric circuit; electrocircuit電路板 circuit board; 電路保持 guard of a c...
  1. Fault location techniques are used to pinpoint location of the fault on a tra - nsmission line. transmission line faults must be located accurately to allow maintena - nce crew to arrive at the scene and repair the faulted section as soon as possible, which can relief the burdens of patrol personnel and reduce the revenue losses due to power outage. the accurate fault location alogrithms play an important role in power system safety, economy and reliability. in this paper, diversified fault location algorithms are summarized. according to the principles of algorithms, they can be classified into two categories : impedence based algorithm and traveling wave based algorithm. based on the analysis and comparission of each algorithm, the corresponding merits and app - lication limitations are presented

    精確的故障定位為現場巡線工作人員及時提供準確、可靠的信息,減輕人工巡線的擔,同時加快線的恢復供,減少因停造成的綜合經濟損失,為提高力系統運行的安全性、經濟性和可靠性發揮重要的作用。本文總結了現有的各種測距方法,根據測距的原理將其分為法和行波法兩大類,對各種演算法的優缺點及適用范圍進行了分析,在此基礎上提出了一種組合的測距方案,並對演算法進行了模擬分析。
  2. This paper discusses the ability of avoiding maximal power flow of quadrilateral impedance relay and round impedance relay in detail and puts forward the setting principle and setting method of load limiting resistor of backup distance protection

    本文對四邊形和方向圓特性器躲線最大潮流的能力進行了詳細分析,提出了距離保護荷限制的整定原則和整定方法。
  3. The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,

    基於基爾霍夫定律的流差動保護無論對於何種形式的輸都是一種簡單、可靠、選擇性強的保護形式,力系統的發展使得流差動保護應用於線保護成為需要,而子、通信技術的發展使得流差動保護應用於輸成為可能。首先,本文對目前線保護的研究和實際應用情況進行了討論和分析,比較了常用線縱聯保護的實現原理和實現條件及優缺點。其次,針對常規相量流差動保護易受正常流和故障過渡影響的缺點,同時為加快差動保護的動作速度,對基於故障分量瞬時采樣值流差動保護的原理、判據、動作特性等作了討論和分析,結果表明基於故障分量瞬時采樣值流差動保護在可靠性、靈敏度、流互感器飽和方面明顯優于常規相量流差動保護,對流差動保護各端的同步采樣方法和數據通信也進行了分析和評價。
  4. The pt secondary loop voltage drop is a changing amount and has the characteristics of indirection and certain randomness. the second, according to the cause of pt secondary loop voltage drop, the different methods to reduce the pt secondary loop voltage drop were analyzed and the conclusions are draw as below : 1. changing bigger section wire and maintaining the connector plugs regularly can reduce the pt secondary loop voltage drop effectively, but ca n ' t guarantee which meets the relevant rules

    首先,通過對壓互感器二次壓降的形成機理進行分析,得出以下關於二次壓降的相關結論: 1 、壓互感器二次壓降等於二次迴和迴流的乘積; 2 、壓互感器二次迴分為元器件自身和接觸兩部分,且接觸佔主要部分,從而使得壓互感器二次迴具有動態特性,而且具有一定的隨機性; 3 、壓互感器二次迴流與二次荷和迴大小相關,因而二次迴流也是變化的; 4 、壓互感器二次壓降是一個變化量,且具有單向性和一定的隨機性。
  5. The basic software consists of topology analysis, on - line load flow computation, state estimator, security analysis, dispatchers training simulator, short circuit current computation, and voltage / reactive power optimize, etc. the derived softwares consist of load control, capacitor optimizer configuration, transformer and feeder load distribution, impedance computation of generator, etc. network analysis software is powerful dispatch tool, though witch the current state of the power system can be realize, then improve the security and economic potential

    Dms網分析的基本軟體有:網結線分析、潮流計算、狀態估計、荷預報、短流計算、壓無功優化等。派生軟體有:荷控制、容器優化配置、變壓器與饋線荷分配、計算等。網分析軟體是有力的調度工具,通過它可以了解和掌握當前的運行狀態,從而挖掘安全和經濟方面的巨大潛力。
  6. The current in the dac ’ s output can drive the load, and the structure can save a buffer consisted of operational amplifier, so the structure can achieve high speed with no close - loop and feedback in this circuit

    該10位分段式流舵型數模轉換器的輸出端可直接用流輸出來驅動,省去運算放大器構成的輸出緩沖,整個中沒有形成閉環和反饋,因此這種結構可以達到很高的速度。
  7. In order to drive a high impedance load such as hpm sources, it is necessary to commutate fcg ' s long pulse width, high - current and low voltage pulse to a short pulse with high voltage

    為用fcg驅動象hpm源這樣較高載,必須使用脈沖功率調制把fcg產生的低壓、大流、上升時間長的壓脈沖轉化為高壓、上升時間短的脈沖。
  8. The three - phase circuit that has balanced three - phase sources, balanced ( equal ) three - phase loads and balanced three - phase line - impedances is called a balanced three - phase system

    一個具有對稱三相源,對稱三相載和對稱三相線的三相被稱為三相對稱
分享友人