連梁 的英文怎麼說

中文拼音 [liánliáng]
連梁 英文
coupling wall-beam
  • : Ⅰ動詞1 (連接) link; join; connect 2 (連累) involve (in trouble); implicate 3 [方言] (縫) ...
  • : 名詞1 (屋架中架在柱子上的長木) beam 2 (通常也指檁) purlin 3 (橋) bridge4 (物體中間條狀隆起...
  1. Abstract : the paper probed the analysis on the adding mode of perpendicular load in multistorey building structures, the bending moment of frame side beams and the top, the bending moment of secondary beams, the difference between the tie - beam, plane - frame analysis and the space analysis on the path of conduct force, ect. it can be used as a reference when probing these problems

    文摘:討論了在多項高層建築結構分析中垂直荷載加載模式的選擇,框架邊和次端部的彎矩計算,連梁問題和平面框架分析與空間分析在傳力路徑上的差別以及單片剪力墻平面外彎矩等問題,可供同類結構內力分析時參考
  2. Tie beam is an important element in frame - shear wall structure

    連梁在框架-剪力墻結構中,也是很重要的一個構件。
  3. The ratio of span - height of an ordinary tie beam is always less 2. 5, so the resisting shear is difficult to achieve

    由於一般連梁跨高比小於2 . 5 ,使得受剪承載力很難滿足。
  4. In particular, the concealed bracings have more evident effects in improving bearing and energy - dissipation capacity of the wall slabs in coupled shear walls with lintel beams of relative smaller span - height - ratio. 4

    特別是在連梁跨高比相對小的雙肢墻墻肢中增加暗支撐對雙肢墻承載力、耗能提高的作用更為明顯。
  5. The influences of different reinforcement style of the concealed bracings and different span - height ratio of lintel beams on bearing capacity, stiffness and deterioration process, ductility, hysteresity capacity, energy dissipation and failure features of coupled shear wall were studied through experiment of 7 specimens under low cyclic loading

    通過7個結構試件在低周反復荷載作用下的試驗,研究了不同暗支撐配筋形式、不同連梁跨高比對雙肢剪力墻的承載力、剛度及其衰減過程、延性、滯回特性、耗能、破壞特徵等方面的影響。
  6. Aiming at this important problem to be urgently settled in engineering design, the research group in which the author of this thesis is have carried out a series of test investigations on coupling beams with small aspect ratio

    針對工程設計中這一急待解決的重要問題,本論文作者所在的研究組對小跨高比連梁進行了系列試驗研究。
  7. Finite element simulate analysis of small span - to depth ratio coupling beams with special reiforcement

    特殊配筋小跨高比洞口連梁的有限元模擬
  8. Coupling beams " failure mode, shear distortion, ductility and energy dissipation were impacted by different shear - compression ratio from 0. 15 to 0. 20

    是一種值得推薦的抗震聯肢墻小跨高比洞口連梁的配筋形式。
  9. However, for small span - to - depth ratio coupling beams are counter flexural deep beams restrained at their two ends and points of contraflexure at the center of the span, the rules of their carrying forces and deformation are not like common deep beams

    但是,小跨高比連梁屬于兩端被約束,反彎點在跨中的反對稱彎曲深,其受力和變形規律不同於一般深
  10. In china code for design of concrete structures ( gb 50010 - 2002 ), there are no design methods for coupling beams when the depth - to - span ratio is less than 2. 5, which is one of the critical problems of the code for design of concrete structures unsolved

    並且新頒布的《混凝土結構設計規范》 ( gb50010 ? 2002 )也沒有針對跨高比不大於2 . 5的連梁提出具體的設計方法,小跨高比連梁的設計仍是有待通過試驗研究來澄清的問題之一。
  11. At this background, though coupling beams with the small ratio of the span to depth have no sufficient test results, in order to satisfy the needs of engineering design, the code for design of reinforced concrete high - rise structure ( jgj3 - 2002 ) still adopt the design method of decreasing the maximum shear force and increasing the quantity of stirrups. but in china code for design of concrete structures ( gb 50010 - 2002 ) the content of seismic design methods for these kinds of coupling beams continue to be blank

    在這一背景下, 《高層建築混凝土結構技術規程》 ( jgj3 - 2002 )為了滿足工程設計需要,對小跨高比連梁在沒有充分試驗結果的情況下,仍採用降低最大作用剪力和提高箍筋用量的設計方法(雖然這種方法已被國外試驗證明在跨高比小於1 . 50的連梁中是肯定不能保證延性要求的) ,而《混凝土結構設計規范》 ( gb50010 - 2002 )則把這部分內容繼續留作空缺。
  12. On the one hand, coupling beams with small aspect ratio are sometimes used due to architectural requirement ; on the other hand, because shear walls in frame - shear walls and frame - tube structures bear most horizontal forces, coupling beams with small aspect ratio need be chosen to guarantee lateral stiffness required

    一方面由於建築上的需要,小跨高比連梁時有所見;另一方面,在框架-剪力墻和框架-核心筒結構中,因其中的剪力墻和核心筒承擔大部分水平荷載,故有必要選用跨高比偏小的連梁以保證所需的側向剛度。
  13. Seismic design method of coupling beams with small aspect ratio was one of important problems catching notice at the newly revising structure design codes just completed, and it was discussed seriously at the harmonizing meeting of china code for seismic design of structures, china code for design of concrete structure and the code for design of reinforced concrete high - rise structure. however, because of the insufficiency of experimental research, unanimous opinions were not obtained

    在剛完成的我國新一輪結構設計規范修訂中,小跨高比連梁的抗震設計方法是被關注的重點問題之一,並在《建築抗震設計規范》 、 《混凝土結構設計規范》和《高層建築混凝土結構技術規程》的協調會上作過認真討論,但因試驗研究工作尚不夠充分,未能取得一致意見。
  14. Then the coupling beams with new reinforcement layout were made an inquiry into, and the improvement on the seismic behavior by coupling beams diagonally reinforced with a few rows in end regions was found out at last, based on the observations of the experimental phenomena and the analysis of the measurement result, and by the comparison of seismic behavior by making use of hysteretic response, ductility and energy dissipation behavior, a conclusion is presented : the code for design and construction of reinforced concrete high - rise structures ( the draft asked for advise hi 2000 ) ca n ' t ensure that the coupling beams have fairly good seismic ductility ; the result of improvement of the seismic ductility of the coupling beams by the increase hi stirrups besides the strengthen of longitudinal detailing reinforcement was n ' t obvious ; the coupling beams diagonally reinforced with a few rows in end regions have fairly good mechanisms, and the ductility and the behavior of energy dissipation are better than conventionally reinforced concrete coupling beams, so it is suitable to te tised in short coupling beams

    本文通過對三根小跨高比(均為l h = 1 . 0 )剪力墻洞口在低周反復荷載作用下的試驗,了解了嚴格按《鋼筋混凝土高層建築結構設計與施工規程》 ( 2000年徵求意見稿)設計的連梁具有的抗震性能,研究了採取增大連梁配箍量同時加強縱向構造筋的方案對抗震性能的影響,並進一步對新的配筋形式的連梁進行了探討,了解了在連梁端配置多排交叉斜筋方案對連梁抗震性能的改善。通過對試驗現象的觀察和量測結果的分析,利用荷載?位移滯回曲線、延性和耗能性能等指標對各個試件的抗震性能進行了比較,最後得出結論: 《鋼筋混凝土高層建築結構設計與施工規程》 ( 2000年徵求意見稿)不能保證小跨高比連梁具有較好的抗震延性:通過增大連梁配箍量同時加強縱向構造筋的方案對改善連梁的抗震延性的效果不太明顯;端配置多排交叉斜筋的連梁具有相對較好的受力性能,其延性和耗能性能等各項性能指標均優于普通配筋連梁,宜在深連梁中採用。
  15. Coupling beams between openings are the main plastic energy dissipation elements of coupled walls, but whether short coupling beams could ensure that shear failure would n ' t take place before coupling beams have reached certain displacement ductility or not, is still a problem of engineering which has n ' t been solved and is one of the critical problem of the code for design of concrete structures which remains to be solved

    洞口是聯肢剪力墻的主要塑性耗能構件,但跨高比較小的連梁是否能保證在達到一定的位移延性之前不出現剪切失效,仍是目前我國工程界未解決好的問題,也是我國《混凝土結構設計規范》遺留下來有待解決的關鍵問題之一。
  16. The design and study of coupling beam of reinforced concrete structure

    高層建築鋼筋混凝土連梁的設計和研究
  17. It is a difficult job to adjust the bearing capacity in design

    在設計中,調整連梁受力是一項比較困難的工作。
  18. We respectively allow for each factor that can affect the beam ' s bearing shear capacity before we decide which measure we will apply

    從影響連梁受剪承載力的各個因素分別加以考慮,確定在實際工作中所選擇的方式。
  19. As the first and chief component to anti - earthquake in the shear wall structure designing, the coupling wall - beam, which is designed well or not, affects the anti - earthquake performance of a building

    摘要連梁作為剪力墻結構抗震設計中的第一道防線和主要耗能構件,其設計的合理與否直接影響到建築物抗震性能的好壞。
  20. In this paper, a new ductile rc coupled shear wall, namely rc coupled shear wall with concealed bracings, was put forward based on the study of shear wall with concealed bracings and inclined across steel bars in lintel beam. then the seismic design methods on shear wall with concealed bracings was given through the experimental study and theoretical analysis on seismic behavior and corresponding finite element analysis on elastic - plastic

    本文在帶暗支撐剪力墻及雙肢剪力墻連梁配交叉斜筋的研究基礎上,提出了一種新型延性雙肢剪力墻? ?帶暗支撐雙肢剪力墻,通過抗震性能試驗研究和理論分析,以及相應的彈塑性有限元計算,給出了帶暗支撐剪力墻的抗震設計方法。
分享友人