過負載電平 的英文怎麼說
中文拼音 [guòfùzǎidiànpíng]
過負載電平
英文
overload lever- 過 : 過Ⅰ動詞[口語] (超越) go beyond the limit; undue; excessiveⅡ名詞(姓氏) a surname
- 負 : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
- 載 : 載Ⅰ名詞(年) year : 一年半載 six to twelve months; six months to a year; 三年五載 three to five ...
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 平 : Ⅰ形容詞1 (沒有高低凹凸 不頃斜) flat; level; even; smooth 2 (高度相同; 不相上下) on the same l...
- 負載 : [電學] load
-
The key items include the car sinking, constant speed characteristics, inspection function, auto relevelling function and level accuracy, etc. the research contents focus on the following three parts : firstly, research on effects of system parameters on car sinking has been completed. secondly, the constant speed performance with the compensation of internal leakage of pump / motor is improved. lastly, research on improvement of the car level accuracy and contrast to that of traction elevators is presented, and the reasons of low car level accuracy of hydraulic elevators are discussed
重點研究了三方面內容:一是研究了停層沉降特性及影響電梯轎廂停層沉降特性的各種因素;其次是通過負載壓力補償液壓泵馬達內泄漏來改善電梯轎廂速度穩定性;最後是液壓電梯平層精度的理論和實驗研究,並與曳引電梯的理論模型進行了對比,闡述了液壓電梯平層精度低的原因,理論探討了影響液壓電梯平層精度的主要因素。In at power supply system some transformers with special connection mode, such as scott transformer, anti - scott transformer, balance transformer and so on, are usual used. the voltage ratio is one of important parameters of transformer
採用斯科特變壓器、平衡變壓器等特殊接線方式變壓器作為主變壓器,能有效抑制負序電流,減少有功損耗和電壓損失,提高牽引機車的過負載能力。Solar array simulator is programmed in labview to simulate the running condition of satellite ( such as sun angle, shadow time, orbit and so on ). electronic load is programmed in labview to simulate the running condition of satellite load. by data collecting and processing, satellite power engineers can monitor and evaluate working condition of satellite power system
該測試評估系統應用labview軟體對太陽能電池陣列模擬器進行編程,模擬太陽能電池在空間各種狀態下(軌道、光照角、進出陰影等)的情況;對電子負載進行編程,模擬衛星負載的各種變化(平均負載、短期負載和脈沖負載)情況,信號採集和數據處理單元在測試評估系統運行過程中記錄電源系統各組成部分的工作參數,據此對衛星電源系統進行測試和評估。By analyzing the load factor and unbalance factor of distribution transformer, the method of calculating and selecting the low voltage reactive power compensation capacity and compensation equipments, and the connection mode of capacitors were presented
摘要通過對配電變壓器負載率和不平衡率的分析,提出低壓無功補償裝置補償容量的計算選擇方法和電容器的接線方式。The test results demonstrate that this prototype has excellent comprehensive performances such as small bulk, lower weight, high efficiency, high steady precision, fast dynamic response, wide range input voltage, good output waveforms, strong over - load and short - circuit ability, and strong function with different nature load and three - phase unbalanced load
試驗結果表明,該變流器具有體積重量小、變換效率高、靜態精度高、動態響應快、輸入電壓變化范圍寬、輸出波形質量高、過載與短路能力強、帶不同性質負載和帶三相不平衡負載的能力強等優良的綜合性能。According to the characteristic of nine - area diagram of substation vol / var coordinated control, this system gives the defination of fuzzy sets and the degree of membership of input / output variables, and designs corresponding control rules. the results of simulation demonstrate the system can satisfy the constrains of the day - adjusting times of the switching of on - load transformer and paralleled compensation capacitors, and ensure voltage quality, reactive power basical balance. considering the var requirement in different load time period and the control demand in load saltation, a improved control scheme is provided. the results of simulation show the improved scheme can meet the demand of vol / var in different load time period, protect the wrong operation when either voltage or reactive power appears saltation, and decrease the times of regulation of the switching of on - load transformer and paralleled compensation capacitors finally, a background software module of substation vol / var coordinated control is designed, based on the supervisory control and data acquisition system of substation
模擬結果證明該系統能在各種負荷條件下確保電壓合格和無功基本平衡,且能滿足變電站對有載調壓變壓器分接頭日調節次數和並聯補償電容器組的日投切次數的限制。通過考慮不同負荷時段對無功功率的需求和負荷突變情況下的控制要求,對上述模糊控制策略進行了改進,模擬結果證明改進后的控制策略能滿足不同負荷時段對電壓和無功的要求、抑制電壓或無功突變情況下的誤動作,且有效地減少了有載調壓變壓器分接頭和並聯補償電容器組的調節次數。最後基於變電站scada系統設計了一后臺電壓無功綜合控制軟體模塊。After the analysis of power produce character of the typical three - phases unbalance load, the corresponding circuit is adopted. this main circuit is composed of the power filter series and tcr control circuit. secondly the theory of band - pass filter is analyzed in detail, and then a method of implementing butterworth band - pass filter is put forward
簡要分析了無功補償的基本原理和工作特點,通過對典型的三相不平衡負載工作特點的分析,主電路採用電力濾波器與晶閘管控制電抗器相接合的結構;對用於無功檢測的帶通濾波器進行了分析,設計了用於負載電壓、電流信號濾波的帶通濾波器,並採用運算放大器加以實現。The experiments of motor without and with load on a given frequency are completed in this paper. these results are compared and analyzed. the feasibility of the scheme is validated through the analysis of the results
通過理論分析和對控制系統的設計,作者在dsp電機控制教學實驗及系統開發平臺上對六邊形磁鏈控制演算法進行了初步的開環實驗,完成了電機在一定頻率下空載和帶負載的實驗,並對實驗結果進行了對比分析,結果驗證了系統設計方案的可行性。The d. c. resistance of each phase is also checked against the calculated resistance value for the stator and for balanced resistance between each phase
每個相位的直流電阻也經過與定子的設計負載電阻值進行核對,以確認能夠在每個相位之間進行平衡。分享友人