過電壓 的英文怎麼說
中文拼音 [guòdiànyā]
過電壓
英文
overtension; overstress; overvoltage; excess voltage; superpotential; overpotential過電壓保護(裝置) excess voltage protection; over-voltage protection; surge protection; 過電壓斷路器 overvoltage release-
Discusion about cauterization of the thermal equipment in power plant
裝置中隔離開關操作會產生快速暫態過電壓Tab changer tapping step overvoltage protective device
分接開關級間過電壓的保護裝置Effect of acsr on suppressing power frequency overvoltage of ehv transmission system
對限制超高壓輸電系統工頻過電壓的影響Effect of svc on restricting the temporary overvoltage of ehv transmission system
良導體地線限制超高壓輸電系統工頻過電壓的作用This value △ vipo is equivalent to an overvoltage caused by the ip phenomenon.
Vipo這個值相當于由IP現象引起的過電壓。Saturation overvoltage failure and eliminating measures for potential transformer
電壓互感器飽和過電壓事故及消除措施According to the quickly adjustable characteristic of the peterson coil grounding system, this dissertation proposes a new control strategy. when the system is in operation, the strategy can limit the series resonance over - voltage by using the off - resonance method. when fault occurs, the strategy can conveniently suppressing arc by rapidly adjusting the inductance value of the peterson coil to the point, which the resonance with grounding capacitance of the power network is occurred
依據可控硅控制消弧線圈接地系統的快速可控性,一改傳統的電網正常運行時調節消弧線圈接近於全補償的預調諧方法,提出正常運行時採用脫諧方法抑制串聯諧振過電壓;故障時立即調節消弧線圈電感量達到與對地電容諧振,以利熄弧的新型調節原理和方法。The experiment result shows that the snubber can suppress the over voltage effectively at switch off and its dissipation is little
實驗結果表明,該電路能夠有效防止igbt關斷過電壓,緩沖電路損耗較小。This thesis built the models computing the working frequency over - voltage " operation over - voltage for 220kv fugai transmission line, calculates and analyzes working frequency over - voltage " operation over - voltage using emtp program and provides reasonable protection measures for the transmission line. furthermore, regulations method, traveling wave method and striking distance method are used to study and compare lightning - enduring capabilities of different types of pole in power transmission lines aiming at the fact that the lightning strike switching rate of 220kv fugai line is higher
本文分別建立了計算220kv復蓋線路的工頻電壓升高及操作過電壓的計算模型,利用emtp程序對220kv復蓋線路工頻電壓升高、投切空線過電壓、投切空變過電壓、單相故障過電壓進行計算分析,並提出合理的防護措施。Electric traction ; overvoltage suppressors in d. c. circuits
電力牽引.直流電路中過電壓抑制器This article through installs the reactor with air core in the transformer substation transmission, to control the thunder electric wave amplitude and steepness in the transformer substation ; through over voltage on - line monitoring device testing, inquire into lightning protection of the reactor with air core
本文通過在變電站的輸電線路的出口處加裝空心電抗器,對通過輸電線路侵入變電站的雷電波的幅值和陡度進行抑制;並通過安裝過電壓在線監測裝置進行測試的方法,初步探討了空心電抗器防雷的作用。High voltage shunt capacitor installation is comp - rised of capacitor cabinets or steel racks capacitor, special fuses for capacitor overload protection, capaci - tor discharge device, air - cored reactor which is applied to restrain surge current and high frequency harmonic, zno arrester without gaps for overvoltage - limiting and high voltage vacuum switch etc. capacitor cabinet is
高壓並聯電容器成套裝置主要由電容器櫃或鋼架電容器電容器過負荷保護專用熔斷器放電裝置專用放電線圈或電壓互感器,抑制涌流限制高次諧波的空芯電抗器和限制過電壓的無間隙氧化鋅避雷器及高壓真空開關Based on researching the function of every kind of eliminating arc loop, new concept was brought up in this paper, and the protective device for eliminating arc and overvoltage was researched and manufactured. when the arc light connecting the ground emerges, the chip synthesizing controller control the vacuum contacter which can be operated with dividing phase and make its fault phase earthed so that the arc light can be dissolved thoroughly
本文在研究各種消弧線圈的基礎上,提出全新的概念,研製出了消弧及過電壓保護裝置,該裝置在出現弧光接地時,通過單片機綜合控制器控制一組可以分相操作的真空接觸器,使故障相接地,達到徹底消除弧光的目的。Application guide for surge protection of electric generating plants
發電站過電壓保護的應用導則The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance
爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。In order to enhance the precision, this design proposes that temperature - measuring circuit of platinum resistors and software should be employed to carry on adjustment of measured precision ; it also proposes that the interference of the grid can be reduced by the voltage front feed ; and meanwhile it calls for the application of the photoelectric insulation, the over heating protection and alarm so as to enhance the security performance of the system
為了提高精度,本設計還採用了鉑電阻溫度測量電路,並利用軟體對測量精度進行自校準;通過電壓前饋控制減少電網干擾。此外,設計中還加入了光電隔離措施及過熱自動保護和報警功能,以增強系統的安全性能。The influence of stray inductance in the module circuit to turn - off transient over voltage of igct has been investigated systematically, the surge current calculation has been done by simulation, and the short circuit failure once occurred in experiment has been analyzed by computer simulation, reproduced the breakthrough failure happened in experiment by means of simulation
充分利用計算機模擬的優勢,詳細分析了模塊電路雜散電感對igct關斷過電壓的影響,進行了短路浪涌電流計算,對試驗中發生的短路故障進行計算機模擬分析,重現了試驗中出現的誤觸發貫穿短路故障現象。Divider, coaxial line, trigger, signal processing, data acquisition, acquisition control and waveform analysis software is included in the device. when the device operate in the system, overvoltage is transferred to coaxial line by the divider. if the overvoltage amplitude is higher than initialization value, data acqusition card start sampling. when sampling is over, computer save data to file. engineer can analyse parameter of waveform by appropriative software reading data from file
當裝置在線運行時,系統中出現的過電壓信號通過分壓器傳遞到同軸電纜,通過觸發電路判斷,如果大於預先設定的值則啟動採集卡的同時采樣,采樣結束后,計算機把數據存盤並以文件格式保存,管理人員隨時通過調用專用軟體調取文件進行各種參數分析。Overvoltage amplitude is higher than initialization value, data acqusition card start sampling. when sampling is over, computer save data to file. engineer can analyse parameter of waveform by appropriative software reading data from file. in the trial measurement, the device shows good performance. simulant trial and actual result indicate that method in the paper acquire approving effect, and the device can be used in the lokv distribution network
當裝置在線運行時,系統中出現的過電壓信號通過分壓器傳遞到同軸電纜,通過觸發電路判斷,如果大於預先設定的值則啟動採集卡的同時采樣,采樣結束后,計算機把數據存盤並以文件格式保存,管理人員隨時通過調用專用軟體調取文件進行各種參數分析。General specification of gas discharge tubes for overvoltage protection
過電壓保護氣體放電管總規范分享友人