阻抗變量器 的英文怎麼說

中文拼音 [kàngbiànliáng]
阻抗變量器 英文
impedance transformer
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • : Ⅰ動詞1 (抵抗; 抵擋) resist; combat; fight 2 (拒絕; 抗拒) refuse; defy 3 (對等) contend with...
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 阻抗 : [電學] impedance
  1. In this thesis, the author analyses the deficiency in detecting and controlling function of the computer detecting and controlling system utilized in present transforming station. the strategy of design of software on operation and direction of 5 00kv transformer station is presented. it points out that we can deduce the mathematic analytical formula using the current, voltage and power of two terminals of transmission line as input. on this basis, we do realtime calculation of 500kv transmission line ' s parameter. we can also deduce the linear analytical formula of three - winding autotransformer ' s resistence using its current, voltage and power as input. the corresponding software is programmed on this basis

    論文提出以輸電線路本端和對端電流、電壓、功率作為輸入,導出了超高壓長線的波和傳播常數的數學解析式,在此基礎上進行了500kv輸電線路實時參數計算;提出以三繞組自耦的電流、電壓、功率為輸入,導出了自耦繞組的電、電的線性解析式並進而對的實時參數進行計算;在此基礎上編制了相應的軟體。
  2. Di - on electric one of the beijing hi - new - tech enterprise develop and manufacture lots of equipment like sf6 dewpoint meter dp100, cable fault location system cfl6000 and more. di - on electric supply the most advanced technology and equipment on such as gis surge arrestor on line monitoring, resistance measuring, ac dc metrology, thermal - temperature bridge, power transformer diagnostic and testing, cable diagnostic and fault location, sf6and oil moisture measuring, oil treatment and testing, optic fiber temperature monitoring, circuit breaker testing, relay testing and more

    迪揚電氣在gis和避雷的帶電測試與故障診斷分析,電力電纜的故障定位與局放檢測,的各種測試診斷與溫度監測, sf6的水分測與回收,絕緣油的測試分析與濾油處理,紅外測溫與光纖在線測溫,以及各種電測試與計,溫度計與電能計等方面擁有世界一流的技術與成熟的儀設備。
  3. 3. we do short circuit analysis upon multiple magnetic circuit transformers by use of steady non - linear analysis and get the leakage reactance respectively between high voltage and high voltage 、 high voltage and low voltage 、 two high voltage and low voltage 、 low voltage and high voltage and low voltage and two high voltage. what ’ s more, we do finite element analysis upon the temperature field of transformers and according to its distribution we get the wind speed to forced air cooling

    3 、採用穩態非線性分析法對多磁路進行短路計算,利用能法計算出高壓與高壓、高壓與低壓、兩高壓與低壓、低壓與高壓以及低壓與兩高壓之間的漏感;對的溫度場進行有限元分析,確定溫度場分佈情況。
  4. Applying relative arithmetic to all kinds of faults and calculating off - line, we can master time - distance relation chart for all kinds of faults. computation indicates : when transmission lines occur faults, the data window of protection algorithm consisting of prefault and postfault data at the same time has important significance. the following methods are useful to achieve the inverse time characteristic : calculating impedance by using flourier in a full cycle, calculating work voltage by using fault component, calculating the torque created by a phase comparator or a magnitude comparator

    實際的計算表明:輸電線路發生故障后,用故障前後的數據同時充滿保護演算法的數據窗,對于快速切除近區故障具有很重要的意義;同時利用故障前後的數據,下述方法可以比較好地實現距離保護的反時限特性:直接用全周傅里葉演算法進行計算;採用工頻繼電進行工作電壓的計算;採用轉矩的思想進行轉矩的計算。
  5. The pt secondary loop voltage drop is a changing amount and has the characteristics of indirection and certain randomness. the second, according to the cause of pt secondary loop voltage drop, the different methods to reduce the pt secondary loop voltage drop were analyzed and the conclusions are draw as below : 1. changing bigger section wire and maintaining the connector plugs regularly can reduce the pt secondary loop voltage drop effectively, but ca n ' t guarantee which meets the relevant rules

    首先,通過對電壓互感二次壓降的形成機理進行分析,得出以下關於二次壓降的相關結論: 1 、電壓互感二次壓降等於二次迴路和迴路電流的乘積; 2 、電壓互感二次迴路分為元件自身和接觸兩部分,且接觸佔主要部分,從而使得電壓互感二次迴路具有動態特性,而且具有一定的隨機性; 3 、電壓互感二次迴路電流與二次負荷和迴路大小相關,因而二次迴路電流也是化的; 4 、電壓互感二次壓降是一個,且具有單向性和一定的隨機性。
  6. The low voltage impulse method, frequency response analysis method and short - circuit reactance method, which can be used to measure and diagnose the deformation of power transformer winding, are introduced in the paper

    目前,監測繞組形的方法主要有低壓脈沖分析法( lvi ) ,頻率響應分析法( fra )和分析法。這些方法都需使退出運行,在離線情況下對繞組形進行測的。
  7. Then, based on the estimation algorithm decomposing the measurement of voltage scope and power scope, the problems of the location of transformation tap settings and the tide current estimation of zero - impedance branches in state estimation are solved ; and detection and identification of bad data in state estimation are deduced and stimulated, also a hybrid method of detection and identification is brought forward

    隨后,在基於分解電壓測和功率測的估計演算法的基礎上,對狀態估計中經常出現的抽頭位置問題和零支路潮流估計問題進行了分析和處理;對狀態估計的不良數據檢測與識別方法進行了推導和模擬,並提出了一種混合檢測方法。
  8. Presents the simple but highly reliable on - line detection of ultrasonic transducer clamping capacitance based on the impedance circuit model constructed through the impedance characteristics of the ultrasonic transducer under triple harmonics, and concludes from experimental results that this method can be used to effectively detect the variation of clamping capacitance while the transducer is operating, and the matching inductance can be dynamically regulated according to the results of detection, and dynamic matching can therefore be achieved in the real sense at the end of the transducer to improve the overall performance of the whole system

    為了解決大功率超聲應用的換能電端匹配問題,分析了超聲波換能在諧振頻率三次諧波下的特性,給出了超聲換能三次諧波下的電路模型.並根據電路模型建立了對超聲換能的夾持電容實現在線檢測簡單、可靠性高的方法,實驗證明該方法有效的.該方法可以在換能工作過程中隨時檢測夾持電容的化,根據檢測結果對匹配電感進行動態調整,實現真正意義上的換能電端的動態匹配,從而大大改善匹配質,提高系統的工作性能
  9. Those algorithms are reviewed, and their disadvantages are proposed. this thesis provides a new approach for protecting power transformers. the technique uses positive - and negative - sequence impedance and variation of magnetizing impedance, where phase voltages are used

    本文從機理上對保護進行新認識,將電壓引入了保護中,採用了基於序基頻和勵磁化的保護方法。