電弧電流 的英文怎麼說
中文拼音 [diànhúdiànliú]
電弧電流
英文
arc current-
Industrial limited company of electrical machinery of branch water makes the arc arc welding generator of three - phase direct current professionally, exempting and is shocked by electricity the dangerous advantage, stop the worker fitting the accident and happenning, 200 to 600 amperes are complete in specifications
清水電機工業有限公司專業製造三相直流電弧電焊機,擁有免遭受電擊危險優點,杜絕工安事故發生, 250至600安培規格齊全。New designed auto tracing arc eliminating device based on this technique contents more technology, which has sample circuit, wide tuning scope, quick response and low noise. this paper firstly introduces neutral grounding histroy. by analyzing the syntony grounding theory, the transient and stable process of one - phase grounding fault, the threaten to secure run of power system and the importance of exact compensation for capacitive current are cognized
論文中首先介紹了中性點接地方式的發展過程,通過對諧振接地原理和單相接地故障的暫態、穩態分析,認識到接地故障對系統安全運行的危害,通過消弧線圈對接地電容電流的迅速準確補償是減小故障危害的最主要手段。Backing weld procedure technique of all - position narrow gap and thick - walled pipe welding is developed about all - position single - pass welding section analysis, wire feeding behavior, weld arc length, welding current analysis, procedure and joint test. the achievement has general guide meaning to producing and testing all - position welder
從單焊道全位置區段、送絲行為、焊接弧長(電壓) 、電流行為分析、工藝試驗和接頭檢驗等幾方面介紹管道全位置打底焊工藝特點,其研究成果對全位置焊接機的製造和調試具有普遍指導意義。Abstract : backing weld procedure technique of all - position narrow gap and thick - walled pipe welding is developed about all - position single - pass welding section analysis, wire feeding behavior, weld arc length, welding current analysis, procedure and joint test. the achievement has general guide meaning to producing and testing all - position welder
文摘:從單焊道全位置區段、送絲行為、焊接弧長(電壓) 、電流行為分析、工藝試驗和接頭檢驗等幾方面介紹管道全位置打底焊工藝特點,其研究成果對全位置焊接機的製造和調試具有普遍指導意義。Multiple functions available : start / crater arc current, increase / decrease time, base / crest value current, pulse frequency, pulse rate, post flow time, hf welding
功能豐富:起始/收弧電流、上升/下降時間、基值電流、峰直電流、脈沖頻率、占空比、滯后關氣時間分別可調,高頻引弧。Multiple funcyions available : start / crater arc current, increase / decrease time, base, crest value current, pulse frequency, pulse rate, post flow time, hf / friction welding, water / gas cooling
功能豐富:起始/收弧電流、上升/下降時間、基值電流、峰值電流、脈沖頻率、占空比、滯后關氣時間分別可調,高頻/接觸引弧、水冷/氣冷可供選用。The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance
爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。A production rate as high as 15 % is obtained under the condition of 150torr helium partial pressure, 300a arc current and quick electrode approaching speed as soon as possible. 2
在盡可能快的推進石墨棒的條件下,弧電流300a 、氦氣壓150torr 、無氦氣流時c _ ( 60 )粗品的產率最高,約為15 ; 2Some new phenomenons were discovered. the width of trigger current changes with the discharge condition, it is only 100u. s when let the trigger source work alone, but it can rise up to 300us with the arc current and magnetic field
在研究過程中發現引弧電流脈沖寬度受放電狀態的影響很大,在不引燃主弧時脈寬只有75 s ,而在引燃主弧並在加磁場的情況下會增大到300 s 。Much works has been distributed to the development of a vacuum system to simulate the outer space and a measurement system to test the arcjet performance. ignition experiments in various operational modes have been done with argon as propellant. macroscopical working parameters including thrust, mass flow rate, voltage, current, inlet pressure and vacuity are obtained by the test measurement system and actual performance parameters including specific impulse, thrust efficiency, ratio of thrust and power and ratio of power and mass flow are calculated
以氬氣作為推進劑,在不同工況下進行點火實驗,測量獲得了其工作推力、電弧電壓和電流、推進劑流率和弧室壓力等宏觀參數,得到了不同實驗條件下其工作的實際比沖、推力效率、推力/功率比以及比功率等性能參數,分析了推進劑質量流率、電弧功率、電弧加熱發動機電弧室結構尺寸等因素對其性能的影響,為數值模擬研究和實際的低功率電弧加熱發動機優化設計及研製提供了實驗基礎。Current of arc
起弧電流The influences of several factors such as harmonics, intermittent arc grounding, ct, load and fault resistance have been thoroughly analyzed, therefore, it is fundamental work for its application
深入細致地分析了諧波、間歇電弧、電流互感器、負荷、過渡電阻等多個因素對故障選線結果的影響,為方案的實用化奠定了基礎。Along with the development of power network transmissed in our country, the internal electric power net in industry and enterprise and the electric power sesytem on generating electricity and power supply, the overvoltage phenomena in the electric power sesytem becomes more and more serious
隨著我國電網系統的發展,電力系統中的過電壓現象越來越嚴重,尤其隨著電纜線路逐漸代替架空線路,電容電流不斷增加,弧光接地現象更是不可避免。After the neutral point is grounded through perterson coil, it can decrease the capacitor current through fault point and the over - voltage caused by the grounding fault, which is advantage for the extinguishments of electric arc
中性點經消弧線圈接地后,有效減小了流過故障點的電容電流,減小了弧光接地過電壓,有利於電弧熄滅。After the neutral point is grounded through peterson coil, it can decrease the capacitor current through fault point and the over - voltage caused by the grounding fault, which is advantage for the extinguishments of electric arc
中性點經消弧線圈接地后,有效地減小了流過故障點的電容電流,減小了弧光接地過電壓,有利於電弧熄滅。In the 3 ~ 35kv power supply system of our country, the large part is the not solidly earthed neutral system. when the single - phase earthed phenomena happens in this system, this electric power network can run with failure. and in this way the operated cost can reduce greadty. and at the same time the power supply systemic dependability can be improved. but when the single - phase earthed current is large, this electric power system can engender easily arc earthed overvoltage and interphase short circuit by this means
在我國10 35kv供電系統中,主要為中性點非直接接地系統,這種系統在發生單相接地時,電網仍可帶故障運行,這樣可以大大降低運行成本,提高供電系統的可靠性,但這種供電方式在單相接地電容電流較大時容易產生弧光接地過電壓和相間短路,給供電設備造成了極大的危害。This paper presents the effects of some features on the productivity of raw c60 materials, such as distance and approaching speed of electrodes, helium partial pressure and arc current etc. then we separate and purify the raw materials and obtain pure solid c60 of 99. 9 % and compare the purification efficiency and effect of different fluxion phase and fixed phase and discuss the effects of the experimental conditions, such as the depositing speed, the type of the substrate, the surface structure of the substrate and the temperature of the substrate. finally, we use xps, afm, ultraviolet, infrared and raman to analyze the component, structure and feature of the films qualitatively and quantitatively
本文首先研究了氦氣分壓、弧電流大小、電極間距以及電極推進速度等實驗條件對制備c _ ( 60 )粗品產率的影響;接著選用柱色譜法分離提純得到了純度大於99 . 9的c _ ( 60 )固體,比較了不同流動相和固定相的提純效率和效果;然後採用自己改進后的真空鍍膜機,利用電阻式加熱蒸鍍方法,得到了純c _ ( 60 )薄膜和不同摻雜比的銀摻雜薄膜;探討了沉積速率、襯底種類、襯底表面結構以及襯底溫度等實驗條件對薄膜結構的影響;最後通過xps , afm ,紫外,紅外,拉曼對薄膜的成分、結構和特性作了定性和半定量分析。The results prove that the scheme increases the stability of electrode apparently, current fluctuating has been reduced, speed of system echo has been improved. the system has fine self - adaptive ability and fine ability to resist interference
現場調試結果表明採用的控制方法大大提高了電極控制的穩定性,電弧電流波動降低,系統的快速性大大提高,系統具有較強的自適應能力和魯棒性。In this paper, the research was made to solute these problems. the peterson coil compensation system has been designed which can measure capacitor current and damp degree ; a fault selection method of distribution network which was put forward that based on ftu
本課題就這兩方面的問題進行了深入研究,設計了一種消弧線圈自動補償裝置,該裝置可測量系統對地電容電流和阻尼率,具有響應快、準確性高的優點;同時提出了一種基於ftu的配電網接地選線方法。This paper designs a device of testing the arc shield voltage in the vacuum interrupter, and makes a study of the arcing and after - arcing recovery characteristics of the arc shield by measuring the arc current, the arc voltage, the recovery voltage and the arc shield voltage
本文設計了真空滅弧室屏蔽罩電壓測量裝置,並對真空滅弧室在燃弧和弧后介質強度恢復過程兩個階段的電弧電流、電弧電壓、恢復電壓和屏蔽罩電壓進行了全面、系統的波形測試,研究了真空滅弧室蒸汽屏蔽罩在燃弧和弧后介質強度恢復過程的特性。分享友人