  1. Insulating oils - determination of gassing under electrical stress and ionization

    場和離作下析性測定法
  2. In famous constructions and key projects such as capital international airport, sanxia three gorges hydropower project, nanjing metro subway, qingdao good - world sea palace, jinan railroad sub - bureau, suzhou amusement park, beijing 1st heating power plant, china 2nd autombile plant, xian peace villa, our products continue to operate safely

    其技術性能指標達到目前國內同類產品的領先水平,其空載損耗比s11型配變壓器的空載損耗降低60以上。同時,由於本產品採全密封結構,介質不與空接觸,因而可在潮濕的環境中運行,是城市和農村配網路中理想的配設備。
  3. It s appropriative equipment for electric and industrial enterprises as well as dryness equipment for treating unqualified electric insulation oil and oil adding for electric equipment transformer, capacitor

    力部門及工礦企業凈化處理不合格的專設備也是乾燥力設備潮,對力設備變壓器容器等進行真空注的理想設備。
  4. Standard test method for analysis of gases dissolved in electrical insulating oil by gas chromatography

    體色譜分離法分析中溶解的體成分的標準試驗方法
  5. Standard specification for mineral insulating oil used in electrical apparatus

    裝置中礦物標準規范
  6. In accordance with the technological difficulties encountered in the process of insulation supervision based on the dissolved gases analysis ( dga ), several kinds of model and method are presented to improve the reliability and precision of fault diagnosis of the power transformer. main research content includes : by deeply studying the common transformer faults diagnosing methods, such as three - ratio methods and improved electrical committee agreements, several shortcomings such as uncertainness judgment when the fault reasons, phenomenon and principles come out together while can not consistent to each other etc. for this reason, the old methods can not fully meet the need to engineering practical application. considering fuzzy relationship matrix can fully represents the causality between fault symptoms and fault types, when diagnosing complex equipments with multiple symptoms and fault causes such as power transformer, a synthetic fuzzy diagnosing model is firstly proposed to diagnose transformer ' s insulation faults based on dga in this paper

    本文針對應中溶解體分析方法進行變壓器監督時所遇到的主要技術難點,提出了提高變壓器故障診斷的準確性、可靠性的幾種模診斷方法,主要研究內容有:通過對判斷變壓器故障常的三比值法和改良協研法的深入分析,其診斷準確率較高,但對故障原因、故障現象和故障機理間同時存在不確定性和模糊性的變壓器等設備的故障診斷,難于滿足工程應的需要;在處理變壓器等結構復雜設備的多癥狀、多原因故障診斷時,模糊關系矩陣可以全面反映這種癥狀與故障類型間的因果關系,進而提出了變壓器故障診斷的模糊綜合診斷模型;同時作者還深入分析了模糊運算元的特性;針對常的模糊評判結果的模糊集的集化方法的不足性,提出了將模糊綜合診斷與模糊規則推理結合起來進行故障診斷的方法,能達到較好的效果。
  7. Determination of polychlorinated biphenyle in mineral insulating oils by packed column gas chromatography

    工技術流體.填密柱相色譜法測定礦物中聚氯聯二苯含量
  8. The operation reliability of the power transformer as the key equipment in electrical power systems, influences operation security of electrical power systems directly. the components and contents of gases dissolved in transformer oil can be used to reflects internal insulation faults of operating transformer. in order to overcome the errors caused by complex handling procedure and man - made factors using general chromatogram analysis method, author brings forward an on - line detecting of gases dissolved in transformer oil by using macromolecule polymer to separate oil and gases automatically and an information fusion technology of multi - sensors ; at the same time, in order to improve the accuracy and reliability, author uses neural networks to diagnose transformer faults

    變壓器作為力系統的樞紐設備,其運行可靠性直接影響力系統的安全運行;變壓器中溶解體的成分和含量能有效體現運行變壓器內部的故障情況,為解決常規色譜分析中復雜的操作程序和由於人為因素引起的較大的誤差,論文提出了應高分子聚合膜實現變壓器自動分離、多傳感信息融合技術智能檢測多種體成分的變壓器中溶解體在線監測技術,應神經網路智能診斷方法實施故障診斷,提高變壓器故障診斷的準確性和可靠性。
  9. The research works are shown mainly as follows : 1 ) the actuality and outlook of on - line detecting and fault diagnosis technology of gases dissolved in oil are analysed deeply, and characteristics of insulation structure of power transformer, evaluation of operating reliability and the relationship between ordinary faults inside transformer and gases dissolved in transformer oil are studied too. analysing the purposes of detecting gases dissolved in transformer oil on - line, we can know that primary indexes to evaluate the technology of on - line detecting gases dissolved in transformer oil are reliability of system, accuracy of detected data, validity of diagnosis, automatization and price of systems

    主要研究內容有: 1 )深入分析變壓器中多種溶解體在線監測及故障診斷技術研究現狀及應前景,研究力變壓器結構特性、運行可靠性評估以及變壓器內部常見故障與中溶解體對應關系,通過對在線監測變壓器中溶解體的目的分析得出系統運行的可靠性、監測數據的正確性、診斷的有效性、系統的自動化程度、系統的價格等是綜合評價變壓器中溶解體在線監測技術的指標。
  10. It can remove water content, gas, impurity in oil and enhance withstand voltage, ect performances

    能迅速脫除中的水分體和雜質,恢復提高的耐壓強度等使性能。