電荷等效電路 的英文怎麼說

中文拼音 [diànděngxiàodiàn]
電荷等效電路 英文
charge equivalent circuit
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 荷名詞(蓮) lotus
  • : Ⅰ量詞1 (等級) class; grade; rank 2 (種; 類) kind; sort; type Ⅱ形容詞(程度或數量上相同) equa...
  • : Ⅰ名詞(效果; 功用) effect; efficiency; result Ⅱ動詞1 (仿效) imitate; follow the example of 2 ...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • 電路 : [訊] circuit (ckt); electric circuit; electrocircuit電路板 circuit board; 電路保持 guard of a c...
  1. The main works are listed as follows : ( 1 ) the small capacitance measuring circuit for ect based on the charge amplification principle was deeply analyzed and improved. the stray - immunity and the charge injection effect of this circuit were deeply analyzed. the influence of the charge injection effect was eliminated by practical time sequences and circuit structure differential

    本文的主要工作和創新點如下: ( 1 )對基於放大原理的微弱容測量進行了深入的分析和改進,深入分析了該的抗雜散容性能及注入應問題,通過時序的合理設計消除了注入因素對測量結果的影響,改進了該的數學模型。
  2. This thesis discussed the affection of all kinds of components contingency and the components " position in the line and other factors on the evaluation of load point reliability index. this thesis adopts a integrative method to deal with simple or complex distribution network with the system ' s practical operation characteristics and the results of the example reveal that it is feasible. the key to study the economics of power system reliability is outage costs

    在定量評估負點或系統可靠性指標的研究中,本文較全面地分析了各元件故障和元件在線中的位置以及計劃檢修、臨時停、天氣因素、負轉移因素對估算負點可靠性指標的影響;研究了現有的可靠性評估模型,結合城市網的實際運行特點,採用一種綜合的方法估算輻射型網的可靠性指標,算例結果表明它是有可行的。
  3. It put out the system requirements from the whole structure, function structure, developing mode, user management, the design of software and database, safety design, system running efficiency, developing plan, etc. it put out the basic graphics operation, the module building and editing of the electrical network, the devices records and function management the devices operating management, the function producing the electrical subject chart, the outside interface function, the in - out function and webgis, etc. it discusses some advanced functions including the theory loss and practical loss computing of the distribution line, the reliability basic data producing and conversing tools, power cut management, the load supplying from other ways, the repairing management on user fault reports, th e new load installing assistant function, the management of hanging the cards and simulating operation, the monitonng and analyzing management of the running information, load monitoring and load density analyzing function and so on

    從系統總體結構,功能結構,開發模式,用戶管理,軟體和數據庫設計,安全性設計,系統運行率,開發計劃方面滿足了系統的總體要求;系統實現了基本圖形操作,網建模與編輯,設備臺帳及運行管理,設備操作運行管理,力專題圖生成,外部介面,輸入輸出, web - gis基本功能;系統還具有配理論線損計算及實際線損計算,可靠性基礎數據生成和數據轉換工具,停管理,負轉供功能,用戶報修管理,用戶報裝輔助,掛牌管理和模擬操作,運行信息分析監控管理,負監控及負密度分析高級功能:並能從運行方式,用戶權限,運行日誌三個方面闡述本系統的管理方式。系統總體結構合理,功能及介面齊全,配置擴展方便,可操作性強。
  4. The model experiments results indicate that the pile group composed of extending all around piles can bear inclined load better. this is beneficial to the foundation of transmission tower. the prototype experiments results indicate that the micropile ' s load capacity is satisfied with design

    模型試驗發現,伸向四周的單樁組成的群樁具有更好的抵抗傾斜載的能力,這一點特別有利於輸基礎;原型試驗發現,微型樁單樁和群樁的承載力完全達到設計承載要求,其群樁率在0 . 9左右。
  5. The scale, facility, setup mode and the topper application are increasing, but the network management system still adopts a centralizing structure based on manager / agent model. in the centralizing structure, the network management system can ’ t change with the scale and complexity, which made the system bigger and bigger. all management logic is computing in one workstation, that will occupy too many bandwidth, depress performance and made the workstation become the weakest part, if the workstation overrun or dead, agent can ’ t come back because it must wait manager ’ s command

    目前,我國信網正處于高速發展中,網的規模越來越大,設備種類越來越多,組網方式越來越多樣化,應用越來越復雜,但是網管理系統仍然普遍採用管理員/代理的集中式管理方法,在集中式網管理模式中,網管系統不能隨著網規模和復雜度的變化而變化,致使網管系統越來越龐大;網管理邏輯全部集中在一個管理工作站中計算,需要佔用大量的帶寬來傳輸設備數據,有性差,同時管理工作站是系統中最脆弱的部分,一旦管理方超負或死機,代理方因為必須待管理方的指令而無法恢復系統,導致系統崩潰。
  6. This converter is thermally protected and current limited, protecting the load and regulator during fault conditions. in the circuit design chapter, the basic charge pump operation principle and equivalent circuit model are given first. then two control modes, pulse skip mode and linear mode, are analyzed

    設計中,首先分析了跨周期調制的泵dc / dc轉換的基本原理,然後推導出模型,以此為理論依據分析了泵的兩種控制模式:線性調制模式和跳周期調制模式。
  7. The practical situations of system operations are considered in this paper. based on the enumeration of the cut sets for the load point interruption, load transition character, maintenance of devices, active failure mode and overload of transmission line are all discussed. the evaluation is more realistic and effective

    該方法充分考慮了系統運行的實際情況,在列舉引起負點供停止事件割集的基礎上還考慮了負點供的轉移特性,網元件的計劃檢修和活動性故障,以及系統運行的過負約束諸多情況,使評估過程更加合理和有
  8. This paper analyses model and control system of upfc and tcsc, and respectively completes interface with network, upfc using equivalent load decoupled algorithm and tcsc using compensation algorithm. by programming software, transient stability computation for power system containing facts devices can is realized. the correctness and effectiveness are proved using numerical example in the modified epri - 36 bus system

    本文詳細分析了facts元件中upfc 、 tcsc的模型和控制系統, upfc採用解耦演算法, tcsc採用補償法分別實現了與力網的介面,通過編制相關程序,實現了混合系統中含upfc 、 tcsc的暫態穩定計算,並以修改過的epri - 36節點系統為例,驗證了該演算法的正確性和合理性。
分享友人