電離室裝置 的英文怎麼說

中文拼音 [diànshìzhuāngzhì]
電離室裝置 英文
ion chamber device
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動詞1 (離開) leave; part from; be away from; separate 2 (背離) go against 3 (缺少) dispens...
  • : Ⅰ名詞1 (服裝) dress; outfit; attire; clothing 2 (演員的化裝品) stage makeup and costume Ⅱ動詞...
  • : 動詞1. (擱; 放) place; put; lay 2. (設立; 布置) set up; establish; arrange; fix up 3. (購置) buy; purchase
  • 裝置 : 1 (機器設備的配件)installation; device; apparatus; equipment; arrangement; gear; appliance; rig...
  1. Verification regulation of activity standard device for 4 ionization chamber

    4活度標準檢定規程
  2. The paper mainly focused on the beam transport part of asipp key laboratory of ion beam bioengineering and it ' s component elements, for example, van de graff accelerator, bending magnet, magnetic quadruple lenses, beam shutter, collimator and so on. the laboratory has performed the milestone achievement that is beam passed the hole of lo ^ m diameter in experiments. many experimental results are discussed by theories according to experiments

    本文重點討論了中科院子束生物工程學重點實驗單粒子束的束流傳輸部分,對主要部件進行了詳細的討論,如:靜加速器、偏轉磁鐵、磁四極透鏡、束線開關、瞄準器等,實驗中已取得束流穿過10 m小孔的標志性成果,並運用相關理論結合具體實驗分析了實驗結果。
  3. The effect of detector disturb and the shell of the detector and construction material is not distinct. the low absorb cross section material is used to 235u - fission chamber. the low z material is used in experimental bracket and shielding material and the material is used less

    獲得了探測器之間擾動、探測器外殼、支架材料對信號中子測量無明顯影響的結果;對~ ( 235 ) u裂變,需採用中子吸收截面低的材料,對實驗的支撐材料和屏蔽材料宜選用低z材料且盡量減少用材。
  4. A device was constructed, which is made up of a detector, a three demension micromovement device with high precision which can be controlled at long distance, an enough large target chamber, a serial balzers pressure stabilizing system which can measure and adjust the pressure and an electronic acquiring system to measure the ionization distribution

    它包括探測器、可遠距遙控的高精度三維微動、足夠大的靶系統、可對工作氣體的氣壓進行測量和調節的氣壓穩定系統以及進行分佈研究的子學系統。
  5. The gas sources that we used are trimethylgallium ( tmg ) and 99. 9999 % purity nitrogen, which were fed into reaction chamber and resonance cavity respectively. the highly dense ecr plasma up to 1011cm - 3 was created in the resonance cavity and introduced to the next reaction chamber by the force of divergent magnetic field. consequently, gan thin film was grew on the substrate sapphire ( 0001 ) placed in the downstream

    實驗採用有機金屬三甲基鎵氣源( tmg )和99 . 9999純度的氮氣,在ecr - pecvd150共振腔內子迴旋共振吸收微波能量產生的高密度ecr等子體在磁場梯度和等子體密度梯度的作用下向下級反應擴散,在放於下游區樣品臺上的- al _ 2o _ 3襯底表面附近發生物理化學反應沉積成gan薄膜。
  6. In a room containing a bath or shower, the provision of socket outlets should comply with iec 60364 - 7 - 701 ( to be installed at location 0. 6 m away from shower basin or bath tub ) and the socket outlets should be protected by a residual current protective device ( rcd ) with a residual operating current not exceeding 30ma

    設有浴缸或花灑的浴內,插座應符合國際標準iec60364 - 7 - 701的規定(包括安的位浴盆或浴缸0 . 6米以外) ,並由餘差啟動流不超過30毫安的流式漏斷路器加以保護。
  7. Charged dust particles exist widely in space, laboratory as well as plasma processing

    的塵埃粒子廣泛存在於宇宙空間、實驗的等子體中和材料的等子體加工等環境中。
分享友人