靈敏桿 的英文怎麼說

中文拼音 [língmǐngǎn]
靈敏桿 英文
sensitive rod
  • : Ⅰ形容詞1 (靈活; 靈巧) quick; clever; bright 2 (靈驗) effective Ⅱ名詞1 (精神; 靈魂) spirit; ...
  • : Ⅰ形容詞(靈敏;敏捷) quick; agile; smart; nimble Ⅱ名詞(姓氏) a surname
  • : 桿名詞(桿子) pole; staff
  • 靈敏 : sensitive; keen; quick; agile; acute
  1. Variable voltage and variable frequency ( vvvf ) inverter control technology applied by ford passenger lift extends the utilization from the elevators drive system to the door machine system, plus its matching none link lever synchronous belt type door machine structure, it results in the more smooth sensitive and secure door open and shut. the passengers feel the doubled warmth in entering into and exiting the elevators

    福德乘客電梯所應用的變壓變頻( vvvf )逆變器控制技術,從電梯驅動系統延伸運用到了門機系統中,加上與之相匹配的無連同步帶式門機結構,使電梯門的開啟和關閉更加平穩、和安全,令進出電梯的乘客倍感親切。
  2. The nano - sno2 electrode was used as bioelectrochemical sensor in chronoamperometry to count fastly e. coli with the advantages of quickness, simple operation and high sensitivity

    實驗結果表明,用該電極為工作電極,採用計時電流法能簡便、快速、地對水體中的大腸菌進行計數。
  3. Stable reliability - based sensitivity design of compressive bar

    穩定可靠性度設計
  4. Based on stable reliability - based design theory and sensitivity analysis method, research on stable reliability - based sensitivity design for compressive bar is carried out and a numerical method for reliability based sensitivity design is presented

    摘要在穩定可靠性設計理論與度分析方法的基礎上,研究了壓穩定可靠性度設計問題。
  5. The changing rules of reliability sensitivity are obtained and the effects of design parameters on reliability for compressive bar are studied, which provides theoretic basis for reliability design for compressive bar

    提出了穩定可靠性度設計的計算方法,給出了壓可靠性度的變化規律,研究了設計參數的改變對壓穩定可靠性的影響,為壓穩定可靠性設計提供了理論依據。
  6. Based on above distributed simulation software of multibody system dynamics, three examples of distributed sensibility analysis, double pendulum system, planar four - bar mechanical system and slider - crank system, are numerically dealt with, the results of which indicates that the methods raised in this paper are correct

    基於所完成的系統運動學分散式模擬軟體,實現了雙擺機構、平面四連機構、曲柄滑塊機構的分散式度分析算例,驗證了本文方法的正確性。
  7. Driver ' s position : optimised layout, based on the latest ergonomic principles, considerably reduced vibration and noise, throunh insulating the operator ' s compartment from the vehicle itself by means of shock absorbes, seat adjustable to operator ' s height and weight, as well as being spring suspended and hydraulically damped. lindedouble pedal control system offers accurate reversing without. changing gear. linde central control lever operates all mast functions

    駕駛室:根據人機工程學原理對駕駛室進行了優化設計.駕駛室與車身之間由減震墊隔離,大大地降低了震動和噪音,司機座下有彈簧和液壓減震裝置,並可根據駕駛員的身高和體重進行調整,以獲得最舒適的狀態.林德雙踏板控制系統具有無需切換即可實現向的功能:林德集中控制控制門架的提升,下隆和傾斜動作.發動機的轉速可根據提升和其它功能對輸出功率的需要而自動調節.護頂架與司機座聯成一體,並可裝配成舒適的全封閉駕駛室
  8. The diaphragm had the ability to detect the positive serum when it was diluted to 2 ' 11 and so it has good sensitivity ; stored at 4 for at least 7 months, the sensitivity and specificity of the diaphragm did not change, so it has good stability ; when 10 positive serum was detected 3 times, the result is reproducible, so the diaphragm has good reproducible. serums from experimental inoculated piglets was detected. the results showed that when the titer is l : 16, the pigs were infected with streptococcus suis ; and when 1 : 64, the pigs could survive after challege with streptococcus suis. all the results have shown that dot - ppa - elisa was a convenient, rapid, sensitive specific useful method for the detection of antibody

    該法以硝酸纖維素膜為固相載體,包被膜載抗原製成的診斷膜片具有良好的特異性:不與仔豬副傷寒、豬巴氏菌病、豬大腸菌病、豬衣原體病、豬瘟、豬細小病毒病、豬偽狂犬病、豬布氏菌、豬丹毒陽性血清反應;膜片具有良好的性,陽性血清作2 ~ ( - 11 )稀釋亦能檢出;膜片具有良好的穩定性,在4至少能保存7個月,其性不變。
  9. Based on the perturbation riccati transfer matrix method, the calculating program are developed. the program can be used to the perturbation analysis and the sensitivity analysis of the real and complex, the single and repeated eigenvalues and eigenvectors for lateral vibration of rod and beam structures, especially suitable to the perturbation analysis and the sensitivity analysis of eigenvalues and eigenvectors for rotordynamic systems ; 2. the perturbation riccati transfer matrix method was applied to identify the parameters of the rotor for a boiler supply pump, and the accurate dynamic model of the rotor was archived

    該程序可以對、梁結構橫向彎曲振動的實數、復數的孤立和重頻特徵值問題進行攝動分析和度分析,特別是適合於轉子動力學系統特徵值和特徵向量問題的攝動分析和度分析; 2 、用攝動riccati傳遞矩陣方法解決了某電站鍋爐給水泵轉子的參數識別及動力模型修改的問題,並給出了該種型號的給水泵轉子的更準確的力學模型,為進一步的轉子動力學分析與設計奠定了可靠基礎; 3 、給出了攝動理論在相關領域如隨機特徵值分析、隨機振動響應分析、可靠性分析、度分析、優化設計以及參數識別中的應用公式。
  10. The effect of static magnetic field on the growth of eschrichia coli was discussed by the sensitive response of spqc sensor to the conductivity of solutioa a relative frequency shift response model was derived on the basis of theory analysis and the relative parameters were estimated

    利用spqc傳感器對溶液電導率的響應,探討了了一定強度的靜磁場對大腸菌的生長狀況的影響。在理論分析的基礎上,導出了相關的頻移響應模型,估計了有關參數。
  11. 107 + 2. 819x ( serotype l ), log [ et reciprocal ] = 1. 019 + 2. 935x ( serotype 2 ), ( 3 ) log [ et reciprocal ] = 0. 99 + 2. 709x ( serotype 4 ) and log [ et reciprocal ] = 1. 052 + 2. 953x ( serotype 5 ). the derived regression lines ( equations ) were used to transfer the optical density value ( od ) obtained from a single 1 : 100 dilution of any unknown serum sample of duck into elisa titer. the indirect elisa technique were used to monitor the variety of the mean antibodies titers of vaccinated ducks with the oil - emusified formalin - inactived r. a

    間接elisa方法的度是微量凝集試驗的50 - 100倍(血清1型鴨疫里默氏菌) , 25 - 100倍(血清2型鴨疫里默氏菌) , 12 - 100倍(血清4型鴨疫里默氏菌) , 25 - 200倍(血清5型鴨疫里默氏菌) 。
  12. The high specificity of dot - ppa - elisa was proved by the specific blocking test, and also by the cross - reaction test in which the diaphragm did n ' t react with the antibodies against pasteurellosis, streptococcosis, colibacillosis, chlamydiosis, hcv, ppv, brucellosis, prv and foot - mouth disease. the diaphragm has good sensitivity and could detect some salmonella - positive test serum which has been diluted to 1 : 2048. stored at 4 for at least 6 months or at 10 - 25 " c for 4 months, the sensitivity and specif icity of the diaphragm did n ' t change, so it has good stability

    本研究制備的診斷膜片特異性強:不與豬衣原體病、豬口蹄疫病、豬大腸菌病、豬布氏菌病、豬瘟、豬偽狂犬病、豬細小病毒病、豬巴氏菌病、豬鏈球菌病的陽性血清發生交叉反應;診斷膜片具有良好的感性,能夠檢測到1 : 2048稀釋的動物試驗陽性血清;膜片的保存期長,在10 25可保存4個月、 4條件下至少可保存6個月其度不變。
  13. Against classical dynamic balancers of crank and connecting rod mechanism, the test system has virtue hereinafter : ( 1 ) supporting structure adopt projecting beam uniquely. the signal of vibration provoked by crank and connecting rod mechanism revolving is concentrated to strain beam. the signal is not only abundance, but also easy to test and the test sensitivity is great

    與傳統的曲柄連機構動平衡機相比,這種測試系統具有以下優點:支承結構採用獨特的懸臂梁式結構,曲柄連機構在運轉過程中振動規律完全映射到支承梁的應變上,振動信號豐富且易測試、度高。
  14. The performance of the interface was investigated preliminarily, including the effects of radio frequency quadrupole and sample inlet on the sensitivity

    初步研究了該介面的性能,包括射頻四極、進樣片對儀器度的影響。
分享友人