額定一次電流 的英文怎麼說

中文拼音 [édìngdiànliú]
額定一次電流 英文
rated primary current
  • : 名詞1 (額頭) forehead:寬額 a broad forehead2 (牌匾) a horizontal tablet 3 (規定的數目) a sp...
  • : Ⅰ形容詞1 (平靜; 穩定) calm; stable 2 (已經確定的; 不改變的) fixed; settled; established Ⅱ動詞...
  • : Ⅰ名詞1 (次序; 等第) order; sequence 2 [書面語] (出外遠行時停留的處所) stopping place on a jou...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
  1. The author has finished the following several jobs in core of the centre : 1 ) the active compensation method based on bang - bang control was put forward to realize the wide range current transformer. the method converts the complex statement space to i / o description by the two - stage current transformer. with the compensation method, the accuracy of 0. 2 grade current transformer can be improved to less than the 0. 1 grade standard at 100 % rating when the primary side current is changed from 2 % to 120 % of the rating

    圍繞這工作核心,作者完成了以下幾項工作: ( 1 )以實現寬量程互感器為目標,提出了基於bang - bang控制的有源補償方法,採用雙級互感器,將復雜的狀態控制分量轉化為偏差控制,該方法結構簡單,調試方便,有源補償器輸出小,可以將0 . 2級的互感器經過補償后提高到值的2變化到120時,測量誤差不超過值100時準確度為0 . 1級的測量標準。
  2. In view of this situation this article has conducted research to the design of metallurgy auxiliary biography with the frequency conversion table electrical machinery first multianalysis to the frequency changer and the frequency conversion table electrical machinery movement characteristic is carried out, the voltage waveform harmonious which the frequency changer outputs is big, attacks in a big way, and the voltage climbing rate reaches as high as 6600v / mu s which is 20 times ordinary sine alternating voltage, the rolling mill auxiliary biography table set the extremely strict request to the electrical machinery ; its movement frequency is very low, rate frequency in 8 - 20hz ; the velocity modulation scope is wide, the lowest movement frequency lowers to 1hz, and the starting number of times is quite frequently, each hour reaches as high as 600 - 800 time, the impact shoulders in a big way, the overload capacity request is high

    針對這情況本文對冶金輔傳用變頻輥道機的設計進行了系統研究。首先對變頻器和變頻輥道機的運行特性進行詳細分析,變頻器輸出的壓波形諧波大,沖擊大,壓上升率高達6600v / s ,是普通正弦交壓的20倍;軋機輔傳輥道對機提出了十分嚴格的要求:其運行頻率很低,頻率在8 - 20hz ;調速范圍寬,最低運行頻率低到0 . 5hz ,起動數相當頻繁,每小時高達600 - 800,沖擊負荷大,過載能力要求較高。
  3. Rated primary current

    額定一次電流
  4. With the compensator, the accuracy of an 2 grade current transformers can be improved to less than the 0. 2 grade standard at 100 % rating when the primary side current is changed from 2 % to 120 % of the rating

    在實驗中將準確度為2級的互感器經過補償以後值的5變化到120時,互感器的測量誤差不超過值100時準確度為0 . 2級的測量標準。
  5. Second, since input bias currents are not always small and can exhibit different polarities, source impedance levels should be carefully matched to minimize additional input bias current - induced offset voltages and increased distortion

    ,因為輸入偏置都小,且可能體現不同的極性,而且源阻抗水平應該仔細地進行匹配,以將輸入偏置引起外失調壓和增加的畸變減到最小。
  6. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷路器所造成的事故無論是在數,還是在事故所造成的停時間上都占據總量60以上。因此,及時了解斷路器的工作狀態對提高供可靠性有決性意義;並可以大大減少盲目期檢修帶來的資金浪費。本文論述了斷路器機械特性參數監測方法;提出了二迴路保護器的概念,並將跳、合閘線圈完整性監視和二迴路保護結合起來,給出具有完整性監視功能的二迴路保護器實現方案;根據斷路器生產廠家提供的斷路器短路分斷數,計算每分閘對應的觸頭壽命損耗,預測觸頭壽命;提出根據斷路器殼體溫度和斷路器周圍空氣溫度結合斷路器熱阻來計算斷路器主觸頭穩態溫升的方法,並根據此時的負荷間接計算主觸頭迴路的阻;在硬體路設計上,採用美國ti公司最新推出的種功能強大的單片機msp430 ,並充分考慮該晶元的適用壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作壓晶元之間的介面問題,並給出了直接聯接的接線方案。
  7. Rated accuracy limit primary current of a protective current transformer

    保護用互感器的準確度限額定一次電流
  8. Rated instrument limit primary current

    儀表的極限
分享友人