風換影 的英文怎麼說

中文拼音 [fēnghuànyǐng]
風換影 英文
yifeng-dodge
  • : Ⅰ名詞1 (空氣流動) wind 2 (風氣; 風俗) practice; atmosphere; custom 3 (景象) scene; view 4 ...
  • : 動詞1. (給人東西同時從他那裡取得別的東西) exchange; barter; trade 2. (變換; 更換) change 3. (兌換) exchange; cash
  • : Ⅰ名詞1 (物體擋住光線后映出的形象) shadow 2 (鏡中、水面等反映出來的物體形象) reflection; image...
  1. The fifth chapter sum up the article and view the work. the simulation results indicate : ( 1 ) exchanging of sea - air and force of dynamical and thermodynamic processes is very important to bring and maintain sea surface wind. shf is mostly energy sources and lhf is negative effect in some area

    模擬結果充分表明: ( 1 )感熱和潛熱的海氣交和動量交(摩擦作用)對于海面的發展和維持起著重要作用,潛熱加熱是海面中最主要的能源,感熱通量在一武漢理工大學碩士學位論文定區域對海面場有負面響。
  2. Results show that the influence of mainstream reynolds numbers on heat transfer coefficience is little and the heat transfer coefficience raise with the increase of reynolds numbers. the influence of the position of holes on heat transfer coefficience is complex and correlate with the mainstream speed and the balde surface curvature. and the influence of blowing ratio on heat transfer coefficience is more great ( especially to stator ), and show a complex relation to mainstream reynolds number and the position of holes

    實驗結果表明,不同孔位出流的熱由於孔排下游表面來流速度及葉片表面曲率的不同而有不同的規律,而主流雷諾數對葉片表面特別是壓力面和前緣區域的熱系數比的響較小,吹比對熱系數響較大(特別是導葉) ,並且隨氣膜孔位置和來流雷諾數的變化而情況復雜。
  3. With the impact test of conditioner airport and anti - dust mesh settings on heat exchange gas flow, the paper illustrates that the improper design may reduce gas flow, influence the refrigerating capacity of the system, and increase energy consumption

    摘要通過空調口及防塵網設置對熱氣流流量響的測試,結果表明,若空調口及防塵網設計不當,則可能造成氣流量減少,並響系統製冷量,增大能量消耗。
  4. In chapter 9 we summarize the whole paper, and explain the shortages of this paper and problems to further study. main conclusions of this paper are as follows : the first, state - owned funds have always been predominant in venture capital sources in china, and this caused the " government - operated model " which leads to excessive government ' s interferes and distorted venture capital contracts ; the second, limited partnership contract is better than incorporated company contract, because the former has obvious advantages in not only encouragement and controls, but also in investors " profits. however, this paper insists, incorporated company contracts will still be very popular in the near future because limited partnership still be illegal in most provinces of china ; the third, venture capitalists " share of profits in compensation clause of fundraising contracts is influenced by investors " attitude towards difficulties and obstacles of future investment

    本文研究的主要結論:第一,在我國險資本來源中,政府險資本一直居於主導地位,這造就了我國險投資的「官辦官營」模式,使其契約機制從一開始就帶有「行政干預」的烙印;第二,有限合夥契約在約束機制、激勵機制、投資者收益三個方面都明顯優于公司制契約,因此是我國險融資契約的發展方向,但由於有限合夥在我國受到法律限制,公司制契約在一定時期內仍是我國險融資契約的主要形式;第三,融資契約報酬條款中的激勵系數受主體先驗概率響,借鑒有限合夥契約,可對我國公司制融資契約進行改造與重構;第四,與債權契約、普通股契約相比,可轉優先股契約可以有效緩解險投資過程中的信息不對稱、降低代理成本,因此是我國險投資契約的最優選擇。
  5. This paper includes five parts. the first is to review the study on the subject ; the second is to discuss the characteristic of chian ' s stock market. the change of money - admitted policy and the questions on the study. the third is to verify the size effect in china ' s stock market by using correlation test and regression test on the bases of four different criterions, each criterion will be applied with two time - series methods. the fourth is to summary the main character of four different criterions, and apply joint test to the criterions that were proved the best concerning the size effect. the illiquidity risk was introduced to the study, the indexes of turn - over rate and the fluctuation of turn - over were used here. however, other factors that may influence the invest return rate as circulating rate and size were also included. according to the result, the size effect will be interpreted. the fifth is to summary the size effect and its explaination, and then to provide some useful invest strategies based on the conc lusion above

    論文分五部分,第一部分對小公司效應的有關研究文獻進行回顧;第二部分我國股票市場的狀況、資金供給政策的變化和我國股票市場實證的相關問題進行論述;第三部分對我國股票市場的小公司效應按照四種不同的規模標準分類,每一種標準均分兩種不同的統計周期分段標準進行實證分析;第四部分小結不同的規模分類、不同統計周期分段的統計結果特徵,然後對小公司效應最明顯的規模分類標準進行多因子聯合回歸分析,這里引入了流動性險因素,其用手率和手率波動指標來衡量,還分別引入了其它響投資收益率的因子,分別是規模、流通比例。
  6. Directed by chor yuen, but the original one directed by wang weiyi in 1963 for pearl river film studio. originally a burlesque on the shanghai stage, it was adapted for the screen with leftwing money and a studio under the banner of socialist ideology. the setting was changed to 1940s guangzhou

    七十二家房客本是上海的一滑稽劇,被移形搬去了廣州,在六十年代香港左派公司的資金和社會主義紅旗下的片廠里,重塑羊城四十年代的舊時貌。
  7. The effects of blow ratio and rows on film cooling effectiveness and heat transfer coefficient was studied

    研究了吹比、孔排等因素對氣膜冷卻效果和熱系數的響。
  8. To the large - scale atmosphere, we separate the terms of the horizontal vorticity converting into the vertical vorticity, which considered as the baroclinic terms, from the terms that not including horizontal vorticity by the rules of the p coordinate transforming to the z coordinate in the traditional vorticity equation, and carry out the scale analysis, and then conclude that the baroclinic terms are able to reach the same magnitude grade as the partial derivative of the vertical vorticity to time when it takes place the large scale precipitation in the summer monsoon period in china. by analyzing the game reanalysis data from april to august in 1998 in the region of chinese continent, we found that the baroclinic terms is important to the large - scale cyclone developing above the 600hpa, and the magnitude changing of the baroclinic terms is nearly in - phase as the monsoon movement, so which imply exactly that the magnitude changing of the baroclinic terms is the one of the natural characters of the summer monsoon evolution and equivalent to the movement rule of the subtropical high of the western pacific

    在p坐標垂直渦度方程中,利用p坐標向z坐標轉的公式將水平渦度向垂直渦度轉化的所有項分離出來,這些項具有明顯的斜壓特徵,對其進行尺度分析后,得出在可以忽略潛熱釋放對渦度響的對流層中、高層,此轉化項是大尺度斜壓渦度發展的重要項。通過對1998年48月的game再分析資料進行實際計算也發現,轉化項在東亞夏季上升支的600hpa及以上層次對垂直渦度的局地變化貢獻很大,不能忽略。同時發現水平渦度向垂直渦度的轉化在南海季爆發時和江淮梅雨入梅及發展過程中均有指示性意義,在南海季爆發以後,在中國東南部地區,轉化項的大小與夏季的活躍和中斷等活動有著幾乎一致的變化規律,這從側面也指出了,此轉化項的變化是夏季演變所具有的本質特徵,並且它反映出了西太平洋副高在中國大陸的活動情況。
  9. And, this thesis return as to it ' s measure to measure the proceeding error margin the analysis, and was analyzed by error margin the enthalpy different laboratory matchs the gb / t 7725 - 1996 standard, can be used for measuring the making the cold and making the heat ' s ability, the consuming, the cop, the breeze deal under the steady state or not steady state of air condition of diagraph room, and it can also test the influence of the four channels change to the face valve and and the electronic expanding valve to the whole function of the air condition

    而且,本論文還對其測量量進行誤差分析,經誤差分析該焓差室符合gb t7725 - 1996標準,可用於測量房間空調穩態及非穩態製冷能力和制熱能力、工耗、 cop以及空調器室內機組的量,並能測試四通向閥、電子膨脹閥等控制元件對空調器整體性能的響。
  10. In this research, through the test in geometric parameter and resistance performance, and comparison between random and other stacked packing, pvc screw thread oblique corrugated plate have more advantage. combined with test and theoretic calculate, determined the heat and mass transfer coefficient, obtained the influence relationship between inlet air flow rate, temperature and humidity, inlet liquid desiccate flow rate, temperature and concentration with outlet air humidity in dehumidifier, provided consideration for equipment design and production

    通過對除濕塔的現場測試並結合理論計算,確定其熱質交系數,並分析得出採用pvc螺紋斜波紋板填料的一定結構的除濕塔,處理空氣的量、入口溫度和含濕量及除濕溶液流量、入口溫度和濃度對空氣出口含濕量的響關系,為除濕設備的設計和指導生產運行提供參考。
  11. In a word, this thesis not only expounds the whole structure of stability control of power system based on the theory of control decisions, but also designs software and hardware of sub - control - station, which are different from others. there are several advantages as listed below : 1 ) distributed hardware architecture function modularization realization of communication between modules by high - speed network communication technology ( can ) ( interconnecting 256 modules or mainframes ) flexible, convenient, reliable expansibility of hardware and decreasing system risk. any broken cell only affects local cell

    總之,論文不僅在控制策略理論的基礎上,闡釋了穩定控制系統的整體架構,而且研製設計出新穎的區域穩控子站裝置軟硬體,其優點體現在: 1 )分散式硬體結構體系功能模塊化採用高速網路通信技術( can )實現模塊間信息交(最多支持256個模塊及機箱之間的互聯)硬體擴展靈活方便、可靠,降低系統險,任一單元損壞隻響局部2 )實時信息網(控制網)和管理網(監測網)分開。
  12. The velocity field distribution will vary in the different location of the diffuser

    中送口的位置對地面速度場分佈的
  13. The study has showed that the adjacent zone of supply units strongly influences indoor thermal comfort. to satisfy the indoor human comfort, it is necessary to control the location and the dimension of the adjacent zone

    研究表明:置中送口鄰接區的大小是響室內舒適性的重要因素,為了保證室內人員的舒適性,需要控制好鄰接區的位置和范圍。
  14. In this paper, we have discussed the influences of supply air temperature, supply air quantity, supply air turbulence, as well as mixing ratio of supply unit. all of above parameters are important for the extension of the adjacent zone. consideration of all the parameters is essential for a good system design which can ensure the advantage of displacement ventilation

    本文研究了各種送參數對鄰接區的大小的響,結果表明:送溫差、送量、送湍流度以及送口的摻混量等因素對其都有重要響,在設計時必須仔細平衡這些因素,確定合適的送口和送參數,才能使設計更加合理,充分發揮出置系統的優勢。
  15. The optimum inclination angle is between 15 ~ 20, the length of thermosyphon will not change the phase - change heat transfer coefficient of the evaporation section and the condensation, which will enlarge heat transfer area of thermosyphon and increase the heat exchange capacity. the head - on speed of wind only stranger the heat transfer of the evaporation section and the condensation section. the experiment shows that the mathematic model closely fits to the thermosyphon, moreover, the one key to resolve the thermosyphon effect lies in decreasing the thermoresistance of evaporating section and condensation section. this study can provide directions and experience in the future research

    傾斜角越大,熱虹吸管總熱阻越大,最佳傾角在15 20之間;充液率過多或過少都會對傳熱性能產生不利響,對于本實驗採用的1 . 75m 、 2m 、 2 . 5m 、 3m熱虹吸管,最佳充液率在20 % 35 %之間;管長對傳熱也有響,管長不改變熱虹吸管蒸發段和冷凝段的熱系數,只增加了熱虹吸管的熱面積,增大熱量;迎面速的大小,起到強化熱虹吸管蒸發段和冷凝段熱的目的。
  16. There are many kinds of methods dealing with fresh air supplying, such as free fresh air supplying, fresh air sucking, independent fresh air supplying, heat recovery ventilating ( hrv ), etc. it was proved that ac equipment capability and iaq has a relationship with fresh air states in fan - coiling and fresh air system

    除了無組織的新供應方式,住宅空調系統新供應還有新吸入方式、獨立新供應、新氣機方式。機盤管加新系統中,新處理到不同的狀態點,對空調設備負擔的負荷及室內空氣狀態都有響,本文對各種新處理狀態進行了分析。
  17. The result showed that the contamination situation in the lower zone of the office, i. e. the zone of occupants, was affected by of that of supply air. the supply air contamination should be kept to a low level in order to provide a good indoor air quality. however, the variation of the supply pollutant concentration has no influence on the indoor contaminant distribution of such system

    本文針對氣態污染物,研究了不同送濃度對系統的響,結果表明:置房間的下部區域受送污染物濃度的響較大,人的工作區恰好處于該區,實踐中需要控制好送濃度以保證人呼吸區的空氣品質;但是送濃度的變化並不響置下污染物的分層分佈的特點。
  18. Abstract : in the internal circulating fluidized bed, there exist the moving zone, fluidizing zone and heat transferring zone with different fluidized air velocities. the convection heat transfer coefficient of immersed tube in the heat transferring zone is impacted by the velocity of the moving zone nearby and its data and change trend are obviously different with those of the common bubbling bed. the maximum heat transfer coefficient is evidently higher than that of the bubbling bed. as the bed materials have not been fluidized in the heat transfer zone, the coefficient has increased highly. the curve of that changes gently, feasilble to control the combustion intensity in the fluidizing zone

    文摘:垃圾焚燒系統中,內旋流流化床存在不同布速度的移動區、流動區和熱區,處于熱區的埋管的對流熱系數受附近流動區氣流參數的響,其變化趨勢及數值大小與普通鼓泡型流化床之間有明顯不同:最大的對流熱系數明顯高於鼓泡床;熱區尚未流化時,對流熱系數已經大幅提高;整條熱曲線的變化比較平緩,易於流化床濃相床內熱。
  19. Motorcyclists often adjust position within a lane to be seen more easily and to minimize the effects of road debris, passing vehicles, and wind

    機車通常會在一個車道內轉相對位置,以便更容易看到和降低路面上各種碎片、交會車輛,以及響。
  20. This series is applicable to pipe - winding air - conditioner, machine room air - conditioner, matching of air purification and purification equipments, it is broadly used in the workshops of industrial and mining enterprises, large and small - scale hotels, restaurants, cinema and theatre as well as basement for air - exchanging of ventilating. and also suitable to the low - degree corrosion occasion. the series is divided into three types of 0, 90, 180 degree

    本系列產品適用於機管盤空調、機房空調、凈化空調及各類凈化設備的配套,廣泛應用於工礦企業車間,大小賓館,飯店、劇院、地下室等的通氣,亦可用於有輕度腐蝕場合的通氣,本系列產品分別可做成0 、 90 、 180三種形式。
分享友人