首次陣風 的英文怎麼說

中文拼音 [shǒuzhènfēng]
首次陣風 英文
first gust
  • : Ⅰ名詞1 (頭) head 2 (首領) leader; head; chief 3 (表示方位) aspect 4 (姓氏) a surname Ⅱ動...
  • : Ⅰ名詞1 (次序; 等第) order; sequence 2 [書面語] (出外遠行時停留的處所) stopping place on a jou...
  • : Ⅰ名詞1 (作戰隊伍的行列或組合方式) battle array [formation]: 布陣 deploy the troops in battle fo...
  • : Ⅰ名詞1 (空氣流動) wind 2 (風氣; 風俗) practice; atmosphere; custom 3 (景象) scene; view 4 ...
  • 首次 : for the first time; first
  • 陣風 : gust; thud; blast of wind; gust of wind; puff of wind
  1. Multi - span plastic greenhouse structure design theory has been studied systemic which include design loads, design methods and system optimization designs aimed at the situations above - mentioned, meanwhile, theory analysis and designs have been completed for series east - china multi - span plastic greenhouses in accordance with the local climate characteristic. some elementary conclusions are summed up : ( 1 ) in the aspect of multi - span plastic greenhouse structural design loads researches, based on the contrast analysis of loads provided in foreign and chinese standards, analysis and discussion are mentioned about the definition loads, the estimation and load cases for multi - span plastic greenhouse structural design in details, some conclusions are summed up first : i, wind load : under the present conditions, it is unnecessary to

    得到一些初步的結論: ( 1 )在連棟塑料溫室結構設計荷載研究方面,從分析比較國外關于溫室建築及我國工業與民用建築設計荷載規范的角度出發,針對連棟塑料溫室結構設計中的荷載定義方法、計算取值、荷載組合等進行了較深入的探討和分析,得到以下結論: 、荷載:在現有條件下,考慮壓高度變化系數、作用因子和荷載體型系數,按中國建築結構荷載規范( cbj9 ? 87 )計算荷載是可以的,不必進行重現期博士學位論文摘要修正。
  2. The positions at which the spacecraft first crossed the “ bow shock ” of the magnetospheric interaction with the solar wind, passed closest approach to the planet, and crossed the outbound bow - shock crossing are indicated

    地上飛船跨過"弓形激波"的磁層與太陽的相互作用,通過最親密的態度來處理這個星球,並穿越外弓形激波兩邊的表示。
  3. Here the theoretical model of vav system is set up for the first time. besides, the transfer function matrix of the 5 inputs and the 5 outputs is established by combining the theoretical analysis with the data analysis of experiment. then the non - linear mathematical model of the five loops is delt with in two method : in the first method, taylor progression is applied near the working point of the system in order to make the volume of change between the output and the input become similar to a linear relationship. in the second mothed, the non - linear mathematical model realize linear by means of being devided into sections. the study shows that both the motheds are effective in dealing with the non - linear issue in vav system

    本文建立了變量空調系統的機理模型,並通過採用機理分析和實驗數據分析相結合的方法,建立了所研究的五輸入、五輸出的變量空調系統的傳遞函數矩,並對這五個控制迴路的被控對象的非線性數學模型,採用兩種方法加以處理:第一種方法是在系統的工作點附近進行泰勒級數展開,使輸出的變化量與輸入的變化量之間呈現近似的線性關系;第二種方法是將非線性的數學模型進行分段線性化,即用分段線性化來逼近非線性化的模型。
分享友人