高壓保險器 的英文怎麼說

中文拼音 [gāobǎoxiǎn]
高壓保險器 英文
high-voltage fuse
  • : Ⅰ形容詞1 (從下向上距離大; 離地面遠) tall; high 2 (在一般標準或平均程度之上; 等級在上的) above...
  • : 壓構詞成分。
  • : Ⅰ動詞1 (保衛; 保護) defend; protect 2 (保持) keep; preserve; maintain in good condition 3 (...
  • : Ⅰ名詞1 (險惡不容易通過的地方) a place difficult of access; narrow pass; defile 2 (危險) dange...
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 高壓 : 1 (殘酷迫害; 極度壓制) high handed 2 [氣象學] (高氣壓) high pressure3 (高電壓) high tension...
  1. Our mylar sleeves are mainly used to protect a wide range of electrical equipments, such as thermal protectors, temperature limiting switches, refrigerant compressors, rechargeable batteries, fuses, transformers, motors, electrical wires, electrical ? heating elements, capacitors, telephone relay, soldered dot, tie - in and winding, etc

    我們的聚脂套管主要用於熱溫控制開關、製冷縮機、充電電池、絲、變、馬達、電線、電元件、電容、電話繼電、焊點、接頭、線圈等耐絕緣及機械護。
  2. The way of taking one nth out of capacitor ' s the first harmonic capacitive reactance as its nth harmonic impedance is verified whit the data from tang7c. according to the approximately estimating method, the first harmonic impedance of 220kv system is calculated. on the basis of the models, this paper gives the harmonic equivalent circuit of substation and gives the b ( n ) function of the harmonic time n. when the capacitors has different combination, b ( n ) ' s value will also change, with the inputting local measurement data, the paper studies the series and parallel resonance at the substation, and deduces that the reason the capacitor ' s fuse of tang6c is frequently interrupted is that its capacitor current contains a large number of 5th harmonics, and that the reason the discharging pt of tang7c capacitor being exploded is also that the 7th and 9th harmonic currents are amplified

    據此,對該站進行了串聯諧振分析和並聯諧振分析,並結合測試數據和有關變電站的運行記錄,指出了導致該站電容湯6c頻繁燒的主要原因是5次諧波電流含量偏,引起湯7c放電pt爆炸也是因為7次和9次諧波電流被放大。針對這些導致湯陰變電站補償電容故障的原因,提出了相應的諧波治理措施,包括針對湯6c電容5次諧波電流含量偏的原因,提出了停運湯6c電容或者通過把湯sc電容的部分容量併入湯6c電容(湯sc其餘部分停運)以增加湯6c諧波承受能力的措施;針對# 2變低側7次和9次諧波電流被放大的現象,提出了在湯7c電容上加裝一定百分比的串聯電抗的措施。
  3. A high - voltage fuse is a circuit element put there artificially and designed to melt itself when the fault current exceeds some limit, thereby the circuit could be cut off and the electrical equipment could be protected

    熔斷俗稱絲,是在電網中人為設置的一種最薄弱的發熱元件,是一種當電力系統發生過載或短路故障時,電路或電氣設備的護元件。
  4. The circuit on which the ballast is tested is to be protected by class h non - renewable fuses at ten times the input current rating of the ballast or the next higher ampere fuse rating but in no case less than 20 amperes

    被測試的鎮流的電路由h級的不可再生的絲(是鎮流的額定電的十倍)護著的或者是更安培的熔絲額定值,但是決不能少於20安培
分享友人