adjusting tap 中文意思是什麼

adjusting tap 解釋
調節柄
  • adjusting : 調節;調整;調準
  • tap : vt 1 輕打[拍,敲]。2 補鞋底,打鞋掌;打(著做)出〈如用發報機打出電訊〉。3 選舉,選擇。vi 輕敲,...
  1. This paper has probed into the conditions of the transportation problem " paradox " ' s existence and the adjusting methods of the table - manipulation method, and then put forward the solutions to tap the latent power through the mathematical model of the transportation problem, and finally provided the dual conditions of " the more the fewer " phenomenon

    摘要首先探討了運輸問題「悖論」存在的條件和表上作業法的調整方法,然後指出了通過運輸問題數學模型挖潛的方法,最後給出了「多反而少」現象存在的對偶條件。
  2. In order to ensure the whole system operate economically, power department equip transformer with onload tap changer and shunt capacitors for most distribution substations, according to the operating condition, adjusting the position of transformer taps and capacitors can control the variation of voltage and reactive power exchanger of distribution substations and power system in certain extent

    為確保整個系統運行經濟性,降低網損,電力部門在大多數變電站配置了有載調壓變壓器和並聯補償電容器組,根據運行情況適當調節變壓器分接頭的位置和投切並聯補償電容器組,可以降低電壓變化和變電站與系統的無功交換控制在一定的范圍內,確保供電質量和電網運行的經濟性。
  3. Because of forecasting reactive load at first, it can detect the change of voltage at low - voltage bus from the change of reactive load or the change of voltage at high - voltage bus, then it can decide that adjusting transformer tap or capacitor switch, and avoid blindly and deficient adjusting. on the condition the reactive power is balanced and voltage qualified, it can realize the switching times of loaded taps and capacitors being efficiently decreased

    由於預先預測出無功負荷,提前了解了無功功率變化的趨勢,可以有助於判定低壓母線電壓變化是由無功負荷變化引起還是由高壓側電壓變化引起,從而適時決定是調有載調壓變壓器分接頭還是投切電容器,以此避免了盲目和不充分的調節,實現在保證無功基本平衡和電壓合格率的前提下,減少有載調壓變壓器分接頭的調節和並聯電容器組的投切次數。
  4. Through analyzing the mathematical model of two winding transformer, the effect after on - load tap changing on voltage and reactive power balance at each side, effect of shunt capacitor compensation on voltage and reactive power balance in substation the relation between transformer tap adjusting and shunt capacitor switching in practical grid operation were discussed

    摘要通過對兩卷變壓器的數學模型進行分析,討論了兩卷變壓器抽頭調整后,變電站各側電壓及無功功率的變化;無功補償對變電站各側電壓及無功功率的影響;實際電網生產運行中,無功補償與變壓器抽頭的配合調整。
  5. Considering the characteristics of the high - medium voltage level distribution networks, the voltage / reactive power optimization ( vrpo ) is divided into two sub - problems, switching capacitors and adjusting tap ratios of transformers

    摘要針對高中壓配電網的特點,將電壓無功優化問題分解成電容器投切和變壓器分接頭調整兩個子問題,通過這兩個子問題的交替優化得到最終解。
分享友人