blower performance 中文意思是什麼

blower performance 解釋
通風機性能
  • blower : 抽風機
  • performance : n. 1. 執行,實行,履行;完成;實現;償還。2. 行為,動作,行動;工作。3. 性能;特性。4. 功績;成績。5. 演奏;彈奏;演出;(馴獸等的)表演;把戲。6. 【物理學】演績。
  1. Thermodynamic performance test for centrifugal axial blower and compressor

    離心和軸流式鼓風機和壓縮機熱力性能試驗
  2. Blower performance tester 9. heat exchange unit performance tester

    15 .執行機構綜合試驗室
  3. Abstract : the causes for low efficiency of the heater in no. 2 crude unit of jpc refinery are described and analyzed including water leaking of steam soot blower, dew point corrosion caused by steam, soot deposits in convection chamber owning to poor soot blowing, high flue gas temperature, no heat recovery of flue gas, and poor performance of insulation lining, etc. by using sonic soot removing system, flue gas recovery system, spray coating of fiber and rock wool, as well as adjustment of flow scheme accordingly in the technical revamping. the dew point corrosion is completely eliminated, the insulation performance is improved, the heat loss is reduced by 1. 25 %, the flue gas temperature is reduced to about 170, and the heater efficiency is increased from 83 % to more than 90 %

    文摘:分析了金陵石油化工公司煉油廠二套常減壓裝置加熱爐存在的因蒸汽吹灰器漏水,蒸汽引起露點腐蝕及吹灰效果差造成對流室積灰,排煙溫度高,煙氣熱量未回收利用以及爐子保溫襯里效果差等問題,提出採用聲波除灰系統、煙氣回收系統、纖維噴塗和巖棉噴塗及相應的流程調整等改造措施.測定結果表明,本次技術改造解決了因蒸汽吹灰器漏水所造成的露點腐蝕問題,提高了保溫效果,減少散熱損失1 . 25 % ,排煙溫度降至170左右,裝置的爐效率由83 %左右提高到90 %以上
  4. The causes for low efficiency of the heater in no. 2 crude unit of jpc refinery are described and analyzed including water leaking of steam soot blower, dew point corrosion caused by steam, soot deposits in convection chamber owning to poor soot blowing, high flue gas temperature, no heat recovery of flue gas, and poor performance of insulation lining, etc. by using sonic soot removing system, flue gas recovery system, spray coating of fiber and rock wool, as well as adjustment of flow scheme accordingly in the technical revamping. the dew point corrosion is completely eliminated, the insulation performance is improved, the heat loss is reduced by 1. 25 %, the flue gas temperature is reduced to about 170, and the heater efficiency is increased from 83 % to more than 90 %

    分析了金陵石油化工公司煉油廠二套常減壓裝置加熱爐存在的因蒸汽吹灰器漏水,蒸汽引起露點腐蝕及吹灰效果差造成對流室積灰,排煙溫度高,煙氣熱量未回收利用以及爐子保溫襯里效果差等問題,提出採用聲波除灰系統、煙氣回收系統、纖維噴塗和巖棉噴塗及相應的流程調整等改造措施.測定結果表明,本次技術改造解決了因蒸汽吹灰器漏水所造成的露點腐蝕問題,提高了保溫效果,減少散熱損失1 . 25 % ,排煙溫度降至170左右,裝置的爐效率由83 %左右提高到90 %以上
  5. The whole system has friendly interface, convenient operation and comprehensive functions, which can be used widely in scientific research institutes and factories. the system of blower performance auto - testing improves the stability of testing process, avoids the error of reading, the error of calculation and the error of result causing by relative datas can not be recorded at the same time, the precision and efficiency of testing is largely improved

    整個系統具有界面友好、操作方便、功能齊全等優點,試驗結果表明研製基於虛擬儀器的風機性能自動測試系統,增加了試驗過程的穩定性,避免了人為的讀數誤差、計算誤差以及相關數據不能同時記錄所引起的試驗結果的偏差,提高了測試精度和試驗效率。
  6. Applying virtual instrumentation technology, the author designed the hardware and software of the blower performance testing system. in the hand of hardware, testing data is acquired automatically according to press - difference sensor, press sensor and torch sensor ; blower speed is adjusted automatically according to frequency conversion of transducer and working state is auto controlled according to rotating baffle controlled by the step motor

    硬體上採用壓差傳感器、壓力傳感器和扭矩傳感器檢測各試驗數據,實現了試驗數據的自動採集;利用變頻調速技術控制變頻調速器輸出信號的頻率,實現了風機轉速的自動調節;通過設置旋轉擋板裝置並用步進電機控制其旋轉角度實現了風機運行工況的自動控制。
  7. Blower performance testing is the course of changing working states, measuring testing datas, calculating performance parameters and plotting performance curves which processed under the certain rotate speed. it is important to inspecting finished production and designing new production

    風機性能試驗是在風機轉速不變的情況下,改變風機運行工況、測量試驗數據、計算風機性能參數並繪制性能曲線(流量?全壓曲線、流量?功率曲線、流量?效率曲線)的過程。
分享友人