coolant pressure 中文意思是什麼

coolant pressure 解釋
冷動劑壓力
  • coolant : n. 【機械工程】冷卻劑;(減熱的)潤滑劑。
  • pressure : n 1 壓;按;擠;榨。2 【物理學】壓力,壓強;大氣壓力;電壓。3 精神壓力,政治[經濟、輿論等]壓力。4...
  1. Coolant temperature and ambient air pressure may be used to optimize cold starting and altitude performance.

    冷卻水溫度和大氣壓力可用於使冷起動性能和高原性能最優化。
  2. Presents the steady - state programming with constant coolant average temperature and constant live steam pressure, an ideal programming for marine nuclear power plant ( npp ), under which, both the coolant average temperature and the live steam pressure of nuclear steam supply system ( nsss ) are constant when the steady state operating condition is varied, and points out that in comparison with the steadysate programming with constant coolant average temperature, the ideal programming can improve the overall operating performance of npp effectively, especially in low - load range, for instance, raise the heat efficiency of npp, decrease the operating noise of main coolant pump, and improve the conditions of design, operation and control of the secondary loop system

    雙恆定運行方案是船用壓水堆核動力裝置的理想運行方案.在這種運行方案下,當裝置穩態功率變化時,冷卻劑平均溫度與蒸汽壓都保持不變,與通常採用的冷卻劑平均溫度恆定運行方案相比,有效地改善了核動力裝置的總體運行性能,特別是在低負荷運行時,可以提高裝置經濟性、降低主泵運行噪聲、改善二迴路系統的設計、運行和控制條件,這對于提高船用核動力裝置的運行可靠性和安全性具有實際意義
  3. These measurements are complemented by measurements of the flow field downstream of the cascade. the integrated losses and locations of secondary flow features with and without endwall film - cooling are determined for variations of both coolant supply pressure and injection location

    以無端壁氣膜冷卻和有端壁氣膜冷卻兩種情況進行研究,對比地獲得了兩者的綜合損耗和二次流特徵區域隨冷卻氣體供給壓力和注射位置的變化規律。
  4. At the main content of the thesis, the author collect the main fault ' s character information of primary loop systems, and those systems include main coolant system and pressure safety system and redundant heat discharging system and safety injection system and so on, the author also compare those faults whose character information is similar

    在論文的主要工作內容中,本文收集整理了船用核動力裝置一迴路各系統的主要故障的特徵信息,其中包括一迴路主系統主冷卻劑系統以及主要輔助系統如壓力安全系統、余熱排出系統、安全注射系統等,並對特徵信息類似的故障進行了對比。
  5. Each primary coolant pump will circulate the cooling water ordinary water around the loop through the reactor core at a high pressure of about 155 bar 1 bar 100 kpa. in addition to its

    每一臺主泵會帶動約155巴1巴100千帕的高壓冷卻水普通水在其環路內經過反應堆堆芯循環流動,這些冷卻水不但是用作
  6. The pressuriser is mainly used to maintain the pressure in the primary coolant circuit and prevent overpressure

    穩壓器的主要作用是維持一迴路冷卻水的壓力,防止超壓。
  7. The water level inside the pressuriser and thus the pressure in the primary coolant circuit can be controlled by operation of the heaters and water spray

    透過控制穩壓器內加熱器和噴淋水的運作,便可調節穩壓器內的水位與及控制一迴路的壓力。
  8. Measured hole mass flows and a constant static pressure mixing analysis, together with the measured losses, allowed the decomposition of the losses into three distinct entropy generation mechanisms : loss generation within the hole, loss generation due to the mixing of the coolant with the mainstream, and change in secondary loss generation in the " blade passage

    論文還進行了葉片冷卻孔質量流的測量與常靜壓氣流混合分析,結合前述氣動力損失和冷卻空氣損耗的測量結果表明,端壁氣膜冷卻的綜合損失明顯地由三個部分組成:葉片冷卻孔內產生的損失;由於冷卻空氣與主流熱空氣的混合產生的損失;二次流的變化產生的損失。
  9. Results from this investigation show that the loss generation within the coolant holes is substantial and that ejection into regions of low static pressure increases the loss per unit coolant mass flow. the results also reveal strong interactions between endwall coolant ejection and secondary flow in the blade passage. the secondary flow has a strong influence on coolant trajectories and coolant ejection delays the three - dimensional separation of the inlet boundary layer on the endwall, chang the secondary flow and reduces its associated losses

    本文的研究成果顯示,冷卻孔內產生的損失是主要的,並且低靜壓區域的冷空氣噴射會增加單位冷空氣質量流的消耗;噴射的冷空氣與葉柵端壁流場之間有強烈的相互作用;二次流對冷卻空氣的流動軌跡有較強的影響;冷空氣噴射能延緩端壁入口邊界層的三維分離、改變二次流從而減少其相關損耗。
  10. The primary coolant system of a 900 mw class reactor consists of the reactor pressure vessel and the primary circuit with 3 identical loop top figure

    一個900兆瓦的反應堆主冷卻劑系統上圖是由壓力殼及三個相同的環路相連組成即一迴路。
  11. The primary coolant system of a 900 mw class reactor consists of the reactor pressure vessel and the primary circuit with 3 identical loop ( top figure )

    一個900兆瓦的反應堆主冷卻劑系統(上圖)是由壓力殼及三個相同的環路相連組成(即一迴路) 。
  12. The experiment results indicate that 90 % pressure drop is attributed to minor pressure drop in heat sink and these results are higher than the theoretical value. the thermal resistance will drop with the increasing of pumping work and the extent of the drop will decrease when the pumping work reach some value. the maximal temperature difference between the heat - sink surface and the coolant will increase with the increasing of heat fluxes, as is same to the maximal temperature difference on the heat - sink surface

    研究表明,在微射流熱沉中,熱沉總阻力主要是由局部阻力引起的,佔到熱沉總阻力的90 % ;微射流陣列冷卻熱沉熱阻隨泵功的增加而減小,但是當泵功增加到一定程度時,熱阻變化趨于平緩;熱沉散熱片底面溫度和溫差隨熱流密度增加而升高,但是溫差保持在一定范圍之內。
  13. Rbmk is a type of pressure tube reactor designed in the former soviet union, which uses ordinary boiling water as the coolant and graphite as the moderator

    Rbmk是前蘇聯設計的一種以普通沸水為冷卻劑以石墨為慢化劑的壓力管式反應堆。
分享友人