heat flow rate 中文意思是什麼

heat flow rate 解釋
熱臨率
  • heat : n 1 熱;熱力;熱度;熱量。2 體溫;發燒。3 (氣候的)高溫,暑氣。4 【冶金】熔煉的爐次;裝爐量;一...
  • flow : vi 1 流,流動。2 (血液等)流通,循環。3 流過;川流不息;(時間)飛逝;(言語等)流暢。4 (衣服、...
  • rate : n 1 比率,率;速度,進度;程度;(鐘的快慢)差率。2 價格;行市,行情;估價,評價;費,費用,運費...
  1. For a soil or rock of water - lacked, a heat transfer theoretical model is developed, which is a steady or unsteady, the results show that reservoir temperature, thermal diffusion coefficient, inlet temperature, flow rate of and run time of ground source heat pumps have an effect directly on heat transfer process of dhe. it can deduce that intermit running is favorable for this type of soils and rocks

    對于貧含水地下巖土層建立了穩態與非穩態傳熱的理論模型,分析結果表明,巖土層的熱儲溫度、導溫系數、埋地換熱器進水溫度、流量以及地源熱泵系統的運行時間或開停機比,都對埋地換熱器的傳熱過程產生直接影響,可以推斷,對于該類型巖土層的地源熱泵系統,採用間歇運行將是有利的。
  2. The results indicate that : the high positioned air inflow do good to heat transfer in rotator disk ; different size of radial outflow have small effects on flow and heat transfer ; the heat transfer near rotating disk increases as rotating reynold number increases or non - dimensional mass flow rate increases

    結果表明,高位軸向進氣對轉盤換熱有利;不同的徑向出口大小對盤腔內的流動換熱影響不大;隨旋轉雷諾數和無量綱質量流量增加,轉盤盤面的換熱效果增強。
  3. The rate of heat flow between any two points increases with difference of temperature.

    任何兩點間的熱流動速率則隨溫差的加大而增加。
  4. In this research, through the test in geometric parameter and resistance performance, and comparison between random and other stacked packing, pvc screw thread oblique corrugated plate have more advantage. combined with test and theoretic calculate, determined the heat and mass transfer coefficient, obtained the influence relationship between inlet air flow rate, temperature and humidity, inlet liquid desiccate flow rate, temperature and concentration with outlet air humidity in dehumidifier, provided consideration for equipment design and production

    通過對除濕塔的現場測試並結合理論計算,確定其熱質交換系數,並分析得出採用pvc螺紋斜波紋板填料的一定結構的除濕塔,處理空氣的風量、入口溫度和含濕量及除濕溶液流量、入口溫度和濃度對空氣出口含濕量的影響關系,為除濕設備的設計和指導生產運行提供參考。
  5. This temperature calculation method avoids the non - correspondence between the flow rate and heat flux, which may exists in that used by boiler manufactures, and was employed to calculate the tube temperature of dangerous position that concerns with the retrofit scheme of superheater 1 of tower type coal - fired 330 mw once - through boiler in pucheng power plant for 100 % and 50 % operation load

    針對蒲城電廠330mw塔式燃煤直流鍋爐1號過熱器的改造方案,利用本文提出的方法與電廠鍋爐常用的壁溫計算方法分別計算了100 %與50 %鍋爐運行負荷下危險部位的壁溫。
  6. As the dangerous position needed to be verified has been identified with the known heat flux profile and the characteristics of flow rate distribution, the metal tube temperature of the position can be obtained

    此方法克服了目前常用的電廠鍋爐壁溫計算方法中校核點工質流量與熱負荷並不一定互相對應的缺點。
  7. Of the currently available coolers for electronic products with a high heat flux, microchannel heat sinks have been proved to be able to provide the best heat transfer performance and are one of the most promising coolers. the manifold microchannel ( mmc ) heat sink has many advantages such as low thermal resistance, compact structure, little amount of coolant, low flow rate, uniform temperature distribution along the flow direction and many others, so it is able to provide the best heat transfer performance : lowering the maxmal temperature and the temperature difference

    在目前高熱通量電子產品冷卻器中,微通道熱沉已被證實是傳熱性能最佳且最具應用潛力的冷卻方式之一,而歧管式微通道熱沉因具有低熱阻、結構緊湊、所需冷卻液量小、沿流動方向溫度分佈均勻等優點則成為減小電子元器件換熱表面最高溫度、降低溫度變化的一種有效方法。
  8. The predicted results showed that maximum combustion temperature, smog exit temperature, maximum wall heat flux and averaged wall heat flux would increase with increasing phosphorus mass flow rate when excess - air coefficient or air flow rate was constant

    模擬結果表明,無論過剩空氣系數固定還是空氣流量固定,隨燃磷量的增大,最高燃燒溫度、煙氣出口溫度、壁面平均熱流和最大熱流都呈上升趨勢。
  9. Behavior of flow and heat transfer in venturi tube was simulated numerically and the relationships of outlet temperature, mass fraction of vapor and pressure loss with spraying flow rate were obtained

    當噴射流量小於臨界噴射流量時,出口爐氣的溫度和水蒸氣質量分數隨噴射流量的增大分別呈線性下降和上升關系;當噴射流量大於臨界噴射流量時,爐氣降溫和水蒸氣質量分數增長不顯著。
  10. Through developing a 2 - dimensions heat transfer model of buried pipe - in - pipe heat exchanger and simulating the process by computer, the author figures out inter - relations of factors which influence characteristics of buried pipe - in - pipe heat exchanger, such as pipe diameter, pipe length, ratio of pipe diameters, flow rate, inlet water temperature, patterns of water inlet and outlet, and material features made of pipe, and proposes some optimizing indexes of buried pipe - in - pipe heat exchanger. the author studies the " heat - - short circuit " phenomenon as well and gives < wp = 5 > some important results

    本文通過建立地下套管式埋管換熱器傳熱過程的二維傳熱模型,並藉助計算機對分析結果進行解析,弄清了影響埋管換熱器性能的管徑、管長、管徑比、通過流量、進水溫度、進出水方式以及管材等參數的作用,並提出了相應的優化指標,對研究界懸而未決的「熱短路」問題也進行了細致分析,得出了有關結論。
  11. The theoretical analysis and the simulation of the chain structure model indicate that the fluctuations of mass leaving enthalpy close in on that of distributed parameter model with two - order, two - order, and three order precision at the disturbances of heat flow rate, mass entering flow rate, and mass entering enthalpy

    理論分析及模擬結果表明,該模型在熱流量、入口流量和入口焓的擾動條件下,出口焓的變化分別以二階、二階、三階精度逼近分佈參數模型。
  12. Finally, three foundational principles are presented for the optimal design of the fin system with lower flow resistance and higher heat transfer rate

    在此基礎上,提出並理論證明了低阻力高傳熱的翅片結構的優化設計應遵循的三個基本原則。
  13. The results show that while the mass flow of refrigerant is 1. 85g / s, the inlet temperature of refrigerant is 18. 9, the evaporating pressure is 0. 62mpa, the mass flow of water is 31. 1g / s, and the inlet temperature of water is 36. 9, the refrigerant of miniature evaporator wholly vaporizes in the tube, and the heat transfer rate is 342w. it achieved the demand of design

    經過實驗測試,當製冷劑質量流量為1 . 85g / s ,製冷劑入口溫度為18 . 9 ,蒸發壓力為0 . 62mpa ,水的質量流量為31 . 1g / s ,水的入口溫度為36 . 9 ,此時,螺旋管蒸發器內製冷劑完全蒸發,換熱量342w ,達到了微型蒸發器的預期設計要求。
  14. Using lithium bromide aqueous solution as liquid desiccant, adopting the total heat transfer rate and enthalpy efficiency to describe the combined heat and mass transfer performance and the moisture removal rate and regenerative efficiency to describe the mass transfer performance of the regenerator, explores the effect of air and desiccant inlet parameters on the regenerator performance by experiment, and compares the result obtained with those of other counter - flow configurations previously published

    以溴化鋰溶液為除濕劑,採用總換熱量、全熱效率描述再生器的熱質交換總體效果,採用再生量、再生效率描述傳質效果,實驗測試了溶液和空氣的進口參數對再生器性能的影響,並與逆流再生器的實驗結果進行了比較。
  15. The result shows that the heat transfer coefficient within the hollow fiber module with laminar flow can be calculated based on the correlation. by analyzing the equation, it was founded that the heat transfer coefficient under laminar flow is almost independent of the feed flow rate. numerical simulation of temperature distribution in hollow fiber membrane module with laminar flow was carried out

    首先採用純水為研究體系,研究分析了中空纖維管內的傳熱系數,研究表明,纖維管內的流動屬于層流狀態,其邊界層傳熱系數可用關聯式來計算,由此式看出,層流狀態下,流速對傳熱系數的影響很小。
  16. A solid - liquid fluidized bed has been designed and installed, which will be used in the heat exchanging and descale field. the experimental study for distributor design was carried out and the particles distribution in the tubes of the solid - liquid fluidized bed under different operating conditions was studied by using the ccd measure system. experimental results show that heterogeneous pores distributor which was arranged in the inlet chamber of the solid - liquid fluidized bed can improve the nonuniform distribution of particles in the pipe bundle under high flow rate. the nonuniform decreases by decreasing the mount of pore, but the solid holdup decreases too. the particles distribution is influenced by the position of the heterogeneous pores distributor

    實驗結果表明:在液固循環流化床進口段安裝可調節高度的變孔徑分佈板,能在較高的流速下,較好的改善固體顆粒在管束中的不均勻分佈;開孔率越小固體顆粒在管束中的分佈越均勻,但管束中粒子的平均固含率也越小;分佈板的安裝高度對顆粒的分佈有很大的影響,在實驗范圍內分佈板的安裝距離管束入口處越遠,顆粒在管束中的分佈越均勻。
  17. The results of orthogonal experiment shows that the effect of the volumetric flow of exhaust gases is the most notable ; the effects of the number of exhaust inlets and the heat released rate of fire source are less notable than the effect of the volumetric flow of exhaust gases on the smoke layer interface ; the effects of the separation of exhaust inlets, the interrelation between the number and the separation of exhaust inlets and the location of exhaust inlets are notable ; but the rest factors " effects are not obvious

    實驗結果表明:對煙氣層高度影響特別顯著的是排煙量大小、排煙口數量和火災負荷大小三個因素;排煙口間距,排煙口數量與間距的交互作用,排煙口位置和大小對煙氣層高度的影響也比較明顯;而排煙口大小與間距,大小與位置,大小與數量,位置與數量,位置與間距之間的交互作用對煙氣層高度的影響不大。
  18. The immersion electrical heater is chiefly applied in the direct contact mode of fluid heating. it features fast heat exchange and high thermal efficiency. it has the varieties of water heater, oil heater and gas heater. its heating element power density, i. e. the power per unit of heating area of the heating element, is an important parameter of the electrical heating element, which has a direct bearing on the performance and working life. the working out of the value is a highly specialized problem, being under the influence of many factors ( media flow rate, tempt, physical and chemical properties and direction in which the medium flows past the element etc )

    浸入式電加熱器主要用於直接對流體接觸加熱的場合,具有熱交換快,熱效率高等特點,分為水用加熱器、油用加熱器、氣體用加熱器,加熱元件的功率密度:即電加熱元件單位發熱面積上的功率,它是電加熱元件極重要的參數,直接影響加熱器的使用性能及使用壽命,它的取值是一個非常專業的問題,受到許多因素的影響(如介質的流速、溫度、物理和化學性質及介質流過加熱元件的方向等等) 。
  19. The fem results indicated that as to the rough surfaces in sliding contact, the value of the contact pressure was very high which coursed a high value of the heat flow rate, meanwhile the sliding time was not enough for the frictional heat to transfer, thus the highest value of the body temperature occurred just on the sliding surfaces, which possessed a sharp thermal gradient in direction perpendicular to the sliding surface. so the great thermal stress was caused just by the sharp gradient and the thermal elastic distortion with which the contact pressure changed occurred simultaneously, thus this change of the contact pressure would affect the temperature distribution in return

    對于相對滑動的粗糙表面,因實際接觸面積小而導致接觸壓力很大,這樣使得熱流密度會很大,同時由於滑動時間很短,熱來不及傳導,最高溫度發生在摩擦表面,在垂直於摩擦面的方向有很大的溫度梯度,使得熱應力很大,且最大應力發生在表面,同時產生熱彈性變形,這種變形使得接觸區域內的壓力分佈發生變化,這種變化又反過來影響了接觸區域的溫度分佈。
  20. Disturbances in the recirculating flow regime can produce related variations in the heat release rate in the primary mixing region.

    迴流區域內的擾動可使主要混合區內熱量釋放發生相應的變化。
分享友人