heat pump heating system 中文意思是什麼

heat pump heating system 解釋
熱泵加熱系統
  • heat : n 1 熱;熱力;熱度;熱量。2 體溫;發燒。3 (氣候的)高溫,暑氣。4 【冶金】熔煉的爐次;裝爐量;一...
  • pump : PUMP =politically upwardly mobile personality 政治新星,政治上有望晉升人士。n (淺口無帶的)輕舞...
  • heating : adj. 1. 加熱的;供熱的。2. 刺激的。n. 1. 加熱;供暖;(建築物的)暖氣裝置。2. 白熾,灼熱。
  • system : n 1 體系,系統;分類法;組織;設備,裝置。2 方式;方法;作業方法。3 制度;主義。4 次序,規律。5 ...
  1. Abstract : this essay introduced a coal burning boiler replacement project for a nursing house in beijing, using gd - series high temperature heat pump to gather heat from 15 underground water and output 70 high termperture water to heating system. this project have characteristics of energy saving and environmental friend

    摘要:介紹了北京某干休所燃煤鍋爐改造項目,採用大溫差高溫水源熱泵從15淺層地下水中提取熱量,輸出70高溫熱水進行供暖,從而達到「節能、環保」和節約運行費用的目的。
  2. High temperature water - source heat pump can reclaim loss - grade heat that is produced when energy - changed device such as boiler is operating, anti the return water of district heating supply system is heated

    摘要利用高溫水源熱泵設備可回收鍋爐等能量轉化設備產生大量的低溫餘熱,提高其溫度用於直接供熱。
  3. Ground coupled heat pump system two vertical and two inclined bore holes 32 metres into the earth capture underground heat and provide cooling or heating

    地源熱泵系統由兩個垂直和兩個傾斜的32米深鉆孔及埋管組成,利用地下蓄熱的特性提供熱源或冷源。
  4. The heating, cooling and hot water system with ground source heat pump

    地源熱泵採暖空調熱水三聯供技術
  5. From the performance analysis of the inverter heat pump air conditioner, heat pump type vrf ( variable refrigerant flowrate ) air conditioning system, two - stage compression inverter air source heat pump, and cooling / heating / how - water inverter air source heat pump, the expanded function and performance improvement of air source heat pump from the variable frequency technology are analyzed in this paper

    摘要以變頻熱泵空調器、熱泵型vrf空調系統以及我們提出的雙級壓縮變頻空氣源熱泵系統、供冷/供熱/供生活熱水變頻空氣源熱泵系統為研究對象,分析變頻技術引入空氣源熱泵系統帶來的功能拓展和性能提升。
  6. By considering a single family house of floor area 100m ^ 2, this paper simulates the performance of solar heat pump heating system hour by hour within 10 ~ 15 years

    摘要本文以一個住宅用戶為研究對象,採用10 ~ 15年內全年逐時氣象數據對太陽能生活熱水系統進行模擬。
  7. In view of the present situation of energy consumption on heating water and waste heat utilization, proposes the heat pump hot water system using waste water as heat source

    摘要針對熱水能耗和廢熱利用的現狀,提出了以廢水為熱源的熱泵熱水系統。
  8. Air conditioners ; tests for heating operation of the refrigerating system heat pump

    空調器.第4部分:製冷系統熱力泵的熱起動試驗
  9. In the cogeneration system, heat and power affect each other, heating - pump heating ( air conditioning ) system can not satisfy the peak load very well

    熱電聯產系統熱電相互牽連,熱泵供暖(空調)系統不容易很好地滿足尖峰負荷,鍋爐供暖系統供熱中天然氣燃料構成的成本過高。
  10. With fast development of our country " s gas industry and air ' s increasingly serious contamination in city, using gas instead of coal and supplying energy in high efficiency and cleanliness has become necessary way in city. there are different problems in the current heating ( air conditioning ) systems. in the cogeneration system, heat and power affect each other, heating - pump heating ( aie conditioning ) system can not satisfy the peak load very well, the cost of gas fuel in boilor heating sestem is so high. the high generating efficiency of the diesel - engine two - sourse heating ( air conditioning ) systems is limited in range of 100kw - 1000kw, the heating scope is so limited. combined cycle of two sourse heating ( air conditioning ) system is most suitable selection to buesness community with big scope my paper aim at this syetem ' s primary question when it is applied in our country - - - - bringing project into execution and technology economy feasibility and off - design performence, combined with a certain demonstrating project in beijing buesness community, going along with calculating and analyzing, drawing out some efficient datas and conclusions, based on this, bringing out primary alements affecting combined cycle of two sourse heating ( air conditioning ) system " economics

    熱電聯產系統熱電相互牽連,熱泵供暖(空調)系統不容易很好地滿足尖峰負荷,鍋爐供暖系統供熱中天然氣燃料構成的成本過高,內燃機雙源供暖(空調)系統的高發電效率僅限於100kw - 1000kw負荷范圍,供熱面積有限。對于大面積的商業園區、居民小區,燃燒天然氣的燃氣-蒸汽聯合循環雙源供暖(空調)系統是最佳選擇之一。本論文針對該系統在我國應用時的主要問題- - -方案的技術實施與技術經濟可行性,結合北京某一商業園區示範工程,進行了系統的計算與分析,得到了有效的數據與結論,在此基礎上,提出影響聯合循環雙源供暖(空調)系統經濟性的主要因素,並進行敏感性分析,得出有益的結論;最後通過各種供暖方案的比較分析回答了某些人對該系統的疑慮和不解,並指出系統的優化方向。
  11. With an actual ground source heat pump system example, based on the hourly calculation of annual cooling and heating load, carries out numerical simulation on heat transfer characteristics of the soil around compact pile - buried underground heat exchangers with large land area

    摘要以一實際地源熱泵系統為例,在全年逐時負荷計算的基礎上,對大面積密集型樁埋換熱器管群周圍土壤的換熱特性進行了數值模擬。
  12. ( 4 ) the paper compares the economical efficiency of the vrv heat pump air condition system to the traditional heating systems. form the results, nearly 740, 000 yuan can be saved when this system is be used to maintain 18 ? indoors every year

    通過採暖費用與vrv熱泵空調系統運行費用計算及比較可知,採用vrv熱泵空調採暖在保證冬季室內溫度+ 18條件下,每年可節省近74萬元,經濟效益十分明顯。
  13. The conclusion is drawn that in the quasi two - stage compression heat pump system coupled with ejector, discharge temperature of the compressor is decreased effectively, electric power is reduced, and heating performance is increased compared with those of the flash - tank throttle system in the same conditions. it shows that the quasi two - stage compression heat pump system coupled with ejector improves performances of air - source heat pump in theory

    由結果可以看出:在相同工況下,準二級壓縮?噴射復合熱泵系統可以有效降低壓縮機排氣溫度,所消耗的電功率較閃發器節流系統有所降低,制熱性能有所增加,從理論上說明該系統在解決空氣源熱泵低溫適應性問題上有進一步突破。
  14. The application of water source heat pump system in residential heating and supply air - conditioning

    水源熱泵系統在住宅供熱空調中的應用
  15. Technical retrofit for the domestic water heating system in residential quater of one thermal power plant has been carried out by adopting the boosting and heating technology based on supersonic steam - liquid two - phase flow, to replace the original water pump and tube type heat exchanger

    摘要採用超音速汽液兩相流升壓加熱技術對某熱電廠福利區生活熱水系統進行了技術改造,以取代原有的水泵及管式換熱器。
  16. Application of ground - source heat pump in a hotel heating and air - conditioning system and it ' s economical analysis

    地源熱泵在酒店供冷供熱系統中的應用及經濟性能分析
  17. Experimental study on replacement of r22 with r417a in heat pump heating water system

    2跨臨界膨脹機的開發與實驗研究
  18. This paper introduced the experimental results for ground - source water / water heat pump, analyzed the effects of the variety flux on system performance coefficients, which showed that the optimal operation flux is 1000 ( l / h ) and provided the heat exchange rate per unit depth of coil, 45 80 ( w / m ). compared the exchang - heat - curveline in winter with that in summer, through which showed the advantages of gshp in mode of heating and cooling on long - period operation

    本文介紹了地源水-水熱泵全年冬夏暖冷聯供的實驗結果以及過渡季地溫的恢復情況,分析了系統流量對熱泵性能參數的影響,獲得了最佳運行流量為1000 ( l / h ) 。並實測得到單位管深換熱率及埋管的有關性能指標。
  19. Discussion of ground - source heat pump system for floor heating

    地源熱泵地板輻射供暖系統
  20. Characteristic research and development of solar assisted heat pump water heating system

    干盤管系統中關鍵技術的研究
分享友人