indirect cooler 中文意思是什麼

indirect cooler 解釋
間接冷卻器
  • indirect : adj. 1. 間接的,第二手的;迂迴的;曲折的。2. 不直截了當的,不坦率的,不誠實的。adv. -ly ,-ness n.
  • cooler : n. 1. 冷卻器;冰箱。2. 冷卻劑;冷飲,清涼飲料。3. 〈美俚〉監獄;單人監房;〈軍俚〉兵營倉庫。
  1. In model zw. the indirect heating still is omitted. the condensor adapts calandria heat exchanger. of course the screw plate heat exchange and coil pipe cooler can also be provided as request. when adapt coil pipe cooler, the buffer tank

    冷凝器採用列管式換熱器,也可根據用戶要求供應螺旋板式換熱器,冷卻器採用盤管式冷卻器,採用盤管式冷卻器並配套供應穩壓罐和比重測定器。
  2. 3d numerical simulation of indirect evaporative cooler by cfd method

    對間接蒸發冷卻換熱器的三維數值模擬
  3. Thermal performance analysis of indirect evaporative cooler with condensation in primary airflow

    有冷凝和沒有冷凝的板式間接蒸發冷卻器性能分析比較
  4. Theoretical and experimental study of ellipse tube type indirect evaporative cooler wrapped with absorbing water materials

    包覆吸水性材料橢圓管式間接蒸發冷卻器的理論與實驗研究
  5. The analytical results indicate that the temperature and the concentration of water vapor have been changed in the condition of condensation and also provide evidence of structural optimum of indirect evaporative cooler

    數值模擬以及熱力性能分析的結果表明,冷凝使得間接蒸發冷卻器內部的溫度場、水蒸汽濃度場等的分佈發生了變化,換熱效果以及有用能的利用狀況也發生了變化。
  6. This paper described a cross - flow type of indirect evaporative cooler with condensation in primary airflow. according to the heat and mass transfer performance of indirect evaporative cooler, three - dimensional mathematical model had been established. with the preprocessor gambit, the geometry and mesh generation was completed

    論文根據間接蒸發冷卻過程傳熱傳質的特點,對間接蒸發冷卻器進行了合理必要的簡化假設,應用計算流體力學( cfd )方法,建立了板式間接蒸發冷卻器的三維數學物理模型。
  7. The characteristic curves and diagrams which described the pressure, velocity, and concentration of the indirect evaporative cooler were presented by the software of tecplot and smartdraw. the differences between the condensation condition and non - condensation condition were compared and analyzed

    對比考慮與不考慮冷凝情況下的速度、溫度、濃度等分佈的差異,分析了模擬參數的變化對冷凝的影響。
  8. Based on the results of numerical simulation, the conversion and destruction of available energy had been studied. the exergy destruction in and out of the heat exchanger were also researched. the thermal efficiency and exergy efficiency of indirect evaporative cooler were defined according to the thermodynamic performance of heat and mass transfer

    在大量數值模擬的基礎上,分析了考慮與不考慮冷凝的間接蒸發冷卻過程中能量以及有用能的轉化和損失情況,並根據兩種情況下的收益火用和代價火用的特點,分別定義了火用效率的計算表達式。
  9. For the indirect cooling method, glycol liquid as the secondary coolant is cooled in the refrigerating unit, pumped to the cooler in the house to cool the air. the cooling load is regulated by changing the flowrate of the glycol liquid

    乙二醇間接製冷方式是通過低溫鹽水機組將乙二醇降到一定溫度,通過循環泵將乙二醇溶液供到需要製冷的氣調庫內換熱器中,再由換熱器對庫內環境進行製冷。