line relay system 中文意思是什麼

line relay system 解釋
有線中繼制
  • line : n 1 線;繩索;釣絲;測深度用繩,捲尺。 a fishing line 釣魚線。 be clever with rod and line 會釣魚...
  • relay : n 1 接替的馬;驛馬;接替的狗;(備有接替馬匹的)旅館。2 接替;接替人員;補給供應。3 分程遞送;傳...
  • system : n 1 體系,系統;分類法;組織;設備,裝置。2 方式;方法;作業方法。3 制度;主義。4 次序,規律。5 ...
  1. Di - on electric one of the beijing hi - new - tech enterprise develop and manufacture lots of equipment like sf6 dewpoint meter dp100, cable fault location system cfl6000 and more. di - on electric supply the most advanced technology and equipment on such as gis surge arrestor on line monitoring, resistance measuring, ac dc metrology, thermal - temperature bridge, power transformer diagnostic and testing, cable diagnostic and fault location, sf6and oil moisture measuring, oil treatment and testing, optic fiber temperature monitoring, circuit breaker testing, relay testing and more

    迪揚電氣在gis和避雷器的帶電測試與故障診斷分析,電力電纜的故障定位與局放檢測,變壓器電抗器的各種測試診斷與溫度監測, sf6的水分測量與回收,絕緣油的測試分析與濾油處理,紅外測溫與光纖在線測溫,以及各種電阻測試與計量,溫度計量與電能計量等方面擁有世界一流的技術與成熟的儀器設備。
  2. At the same time, a good program of plc integrated control instead of relay control system that owns much limitation is drew up on the productive line for grinding cane and extracting sugar juice in sugar - refinery

    同時根據現行糖廠壓榨提汁生產線控制系統缺陷,科學提出了用plc集成控制取代傳統繼電控制系統的方案。
  3. According with the specialty of the grinding productive line, the advanced agility and credible plc integrated control system is designed to in place of relay control system that owns bad reliability and bad alterability. the environment is improved. it also meets the tidal current of material transportation controlling, tally with the up trend of the science and technology in the sugar - refinery

    為解決糖廠壓榨提汁生產線的傳統繼電控制系統的可靠性與可更改性差,操作工人工作環境極差等缺點,結合糖廠科技發展的趨勢與當前物料輸送線多採取集中控制的潮流,設計採用了先進、靈活、可靠的plc控制技術對壓榨提汁生產線進行集成控制。
  4. Answer : be familiar with concerned regulations system and line bridge business, have the capacity that handles trouble alone, temporarily relay personnel should be secured, pass labour wu paragraph approval

    答:熟悉有關規章制度及線橋業務,有單獨處理故障的能力,臨時替班人員應固定,並經過工務段批準。
  5. In the system, the low voltage power line is the first signal tunnel without any other relay equipments between customer terminal and substation collector, public telephone line serves as the second signal tunnel between substation and management center computer. as a breakthrough of conventional concept of electricity meter, this thesis initiate a new concept, namely, intelligent power customer terminal ( shortly, customer terminal ), which is developed with spread spectrum plc communication functional and possesses many advanced functions, such as, in addition to electric energy acquisition, guarding against electricity pilfering, preventing wrong connection, protecting malfunction, remote communication ( for example, remote power supply or halt, remote configuration of electricity meter, remote load control, etc ), and so on

    本文首先系統地總結了目前國內外低壓電力網數據傳輸技術的研究現狀和存在的問題,在此基礎上,從理論上論證了在低壓電網上應用擴頻載波數據通信技術的可行性和優越性,並重點論述了擴頻載波技術抗電力線噪聲干擾的機埋;本文提出了一個新穎的基於低壓電力線擴頻載波通信技術的集中遠抄系統的總體方案,即由用戶終端、集中器和電能管理系統所組成的網路系統,其中,用戶終端到配變集中器用低壓電力線作為通道,中間無需其他硬體中繼設備,集中器到電能管理系統用公用電話網作為通道。
  6. At the same time, we have discovered some bug in cooperate between the two type protection, analyzed different result in different condition as config with different logic protection, show that the incorrect relay act result from these bug only appear when line is in incompletely phase operation and occur fault, furthermore the mass computer protection have comprehensive incompletely phase logic, so this condition can not seriously threaten the power system

    同時,也發現了兩種保護裝置在配合上存在一些缺陷,分析了這種邏輯上的不配合在不同情況下所造成的不同後果,並且指出由於這些缺陷所造成的保護裝置不正確動作的情況僅在線路非全相運行時又故障的情況下才可能出現,而且現有的成套微機保護的都具有較為完善的非全相邏輯,在保護裝置正常投運的情況下,還不致對系統安全構成重大隱患。
  7. According the special application background of the single source and the short line in the 110kv power system, the author proposed a feasible protective scheme, in which the power frequency variation distance protect theory with combination to the four - lateral distance relay is used as quick and mainly theory

    本人針對110kv單電源短線路這一特殊應用背景,提出了以工頻變化量距離保護為快速主保護,結合四邊形三段式相間和接地距離保護的保護原理方案。
  8. Especially, the relay protective settings of transmission line are greatly affected by network parameters and framework changing resulted from operational mode of system and the examining and repairing of equipment. so it makes the calculation of relay protective settings more complicated and the more repeated computation work and lasts more time, while the best plan ca n ' t always be achieved

    尤其輸電線路保護整定值受系統運行方式、設備檢修等導致的網路參數和結構變化影響較大,使得其整定計算更加復雜繁瑣,重復計算工作量非常大,耗時較長,而且還不一定能夠得到最優方案。
  9. A few kinds of signal separate measures, double caner frequency automatc switch function and relay function are taken into account on the design of wfplc - ml iniddle - voltage distribution line carrier modem. coupling equipment is designed with the filter and capacitance fitted togethel in this papef, it is also advanced an scheme about caner signal spanning the distribution line break. the equipment system has been finished and put into use, which has better result. the feasibly and necessity of the studying of this problem are posed

    Wfplc3510中壓配電載波系統利用10kv的架空線或電纜,將主控斷發出的命令信息轉換為載波信號通過三相耦合器耦合到電力傳輸線上,在被控端利用單相耦合器耦合到載波信號后轉換為介面信號發送給被控單元,被控單元亦可將返回數據通過單相耦合發送載波信號到主控端,實現信息的雙向傳遞。
  10. As the important part of relay protection devices, the high - voltage transmission line auto - reclosing function acts as the crucial role in ensuring system safety, stability and economical running

    高壓輸電線路自動重合閘功能作為電力系統繼電保護裝置保護功能的重要組成部分,它在保證系統安全、穩定和經濟運行等方面起著非常重要的作用。
分享友人