oxygen-sensitive 中文意思是什麼

oxygen-sensitive 解釋
對氧敏感的
  • oxygen : n. 【化學】氧,氧氣。
  • sensitive : adj 1 有感覺的。2 敏感的,感覺靈敏的;敏銳的。3 易受傷的。4 (神經)過敏的,神經質的。5 易於發生...
  1. In this thesis, the oxygen sensitive materials and glucose sensitive materials had been developed by thermo - polymerization method including carrier covalence method and carrier covalence - cross linking method, and the properties had been investigated using the detection experiment of oxygen and spectrophotometer, at the mean time, the applications of oxygen sensitive materials in fiber optical gaseous oxygen sensor and fiber optical dis solved oxygen sensor, and that of biology sensitive materials in fiber optical dextrose sensor had been studied in this paper. major content of this work includes five aspects as follows : ( 1 ). oxygen sensitive materials had been prepared by carrier covalence method, and the preparation mechanism of the materials had been investigated by fi - ir, sem, and the detection experiment of oxygen

    本論文主要包括以下五個方面的內容: ( 1 )載體共價法制備氧敏感材料:通過紅外光譜、掃描電鏡圖譜和氧測試實驗探討該氧敏感材料的制備機理,通過氧測試實驗評價該氧敏感材料的氧敏感性和穩定性,同時研究了各種因素對該氧敏感材料性能的影響( 2 )載體共價?交聯法制備氧敏感材料:通過紅外光譜、掃描電鏡圖譜和氧測試實驗探討該氧敏感材料的制備機理,通過氧測試實驗和分光光度計評價該氧敏感材料的氧敏感性和穩定性,同時研究了各種因素對該氧敏感材料性能的影響( 3 )氧敏感材料在光纖氣態氧傳感器中的應用:該傳感器的響應時間為10s ,檢測下限為5ppm ,檢測精度為0 . 5 ,具有較好的重復性和穩定性,遲滯較小,使用壽命至少為1年,適合各種環境下氣態氧濃度的檢測。
  2. Some gas - sensitive test to deoxidizing gas have carried out based on tio _ 2 films by sputtering and doped some impurity. the experimental results showed that tio _ 2 films have different electron injecting principle and reactive mechanism, the behaviors of gas - sensor for hydrogen and ethanol manifest dissimilitude. this is due to that the oxygen vacancies were compensated by the impurity

    用濺射制備的薄膜摻入部分雜質對還原性氣體進行氣敏測試,發現tio _ 2薄膜對酒精氣體和氫氣有不同的反應機制和電子注入機理,氣敏特性也表現出不同,而雜質的引入反而降低了tio _ 2薄膜的敏感性,可能是由於雜質對氧空位的補償所引起。
  3. A novel circulatory system for on - line monitoring of dissolved oxygen that makes use of a fiber - optic chemical sensor is presented. an oxygen sensitive optode was combined with a membrane onto which was immobilized pyrenebutyric acid as a fluoroprobe, the membrane was composed of cellulose triacetate as a polymer and di - 2 - ethyl hexyl -

    就用於水中溶解氧在線監測的光纖光譜儀的搭建傳感探頭的設計及傳感膜的製作進行了探索,並對傳感器的響應性能進行了考察。
  4. A fluorescent reagent membrane was prepared with ru ( phen ) 32 + as raw material and cellulose acetate as carrier, after the study of oxygen ' s quenching function for this fluorescent reagent, the extreme sensitive oxygen quenching function of this fluorescent reagent and its characteristic of fitting the detection of hypoxia environment were discovered

    論文以釕( ) -鄰菲咯啉為原料,醋酸纖維素為載體制備了熒光試劑薄膜並對它的氧猝滅性能進行了研究,發現它具有極為敏感的氧猝滅性能並適用於低氧濃度的檢測。
  5. The sample area can be fully flushed with inertgas for the measurement of samples sensitive to oxygen

    樣品區可完全注滿惰性氣體,用於測量樣品對氧的敏感度。
  6. ( 5 ). glucose oxidase glass micro - pearls, the biology sensitive materials was prepared based on oxygen sensitive materials made by thermo - polymerization method, and could be utilized to detected the concentration of glucose in solution

    ( 5 )氧敏感材料在光纖葡萄糖傳感器中的應用:採用熱聚法制備氧敏感材料並在此基礎上制備了生物敏感材料? ?葡萄糖氧化酶玻璃微珠。
  7. The project detecting the oxygen density by measuring the life - span of the fluorescence quenching has better advantages such as the more sensitive, the better anti - jamming, the more system stabilization, the better dynamic area than by measuring the intensity of the fluorescence quenching

    鎖相檢測熒光壽命的檢測方案相對直接測量熒光強度來測定氧氣濃度的方法而言,具有靈敏度高、抗干擾性強、系統穩定性能好、動態范圍大等優點。
  8. The oxygen sensing properties of the membranes have been studied, the results indicate that the membranes with ru ( phen ) 3cl2 have better oxygen - sensitivity than those with ru ( bpy ) 3cl2, and the membranes with the formamide content of 16 % ( v / v ) and ru ( phen ) 3cl2 content of 2. 10g / l in the precursor mixture have the best structure and quality. the fiber optic gas oxygen sensor with this sensing membrane has a detection limit of 5ppm, a response time of less than 30s, excellent reproducibility and stability. ( 2 ) a new kind of organically modified oxygen - sensitive membrane based on fluorescence quenching was prepared by sol - gel method, using dds and teos as the mixed precursor, rufchenbcla as the indicator

    實驗證明:該類敏感膜的tan _ 0 tan值與氧氣濃度存在良好的線性關系;包埋ru ( phen ) _ 3cl _ 2的凝膠膜的氧敏感性相對較好;當甲酰胺為16體積比含量, ru ( phen ) _ 3cl _ 2在前驅體中濃度為2 . 10g l時,制備的敏感膜結構和性能最佳;對氣態氧檢測時,該敏感膜的響應時間小於30秒,檢測下限為5ppm ,具有較好的重復性和穩定性。
  9. In part i the fluorescence photobleaching characteristics of oxygen sensitive membrane for fluorescence quenching based oxygen sensors are analyzed in details. using laser source and home made heater control circuit, we study the photobleaching model and investigate the characters of wavelength - dependance, intensity - dependance and temperature - dependance of ru ( dip ) 32 + based oxygen sensitive membrane

    文中重點研究了ru ( dip ) _ 3 ~ ( 2 + )絡合物氧敏感膜的光降解模型、氧敏感膜光降解速率與激勵光波長、強度及膜環境溫度的依賴關系。
  10. For instance, the nadir that the body absorbs oxygen tolerance is in afternoon 6 : 00 ; the heart beats and the adjustment of blood pressure is in afternoon 5 : 00 to 6 : 00 between most evenly, and body smell, touch, vision also be in afternoon 5 : 00 to 7 : 00 between the most sensitive

    比如,身體吸收氧氣量的最低點在下午6 : 00 ;心臟跳動和血壓的調節在下午5 : 00到6 : 00之間最平衡,而身體嗅覺、觸覺、視覺等也在下午5 : 00到7 : 00之間最敏感。
  11. Xps measurement results exhibited that no detectable fe2 + existed in the compound of a ~ fe2os doped with sn4 +, which suggest that oxygen anions or cation vacancies not only can compensate the charge balance but also significantly enhance the gas - sensitivity of a - fe2o3 based gas sensors. ( 3 ) conductive type of a - fe2o3 doped with sn4 + is showed in the n - type by hall measurement and gas - sensitivity measurement. the results of measurements and characterizations suggest that the sensitive mechanism of the a - fe2o3 based nano - materials prepared by this work be the surface resistance controlled mode

    ( 3 )首次進行了霍爾測量,並結合氣敏測試結果,從不同方面證實了摻錫- fe _ 2o _ 3納米半導體的導電類型是n型;綜合粉體的電導率?溫度曲線、元件的電阻?加熱電流特徵曲線、元件在不同氣氛下的電阻特性以及比表面積等測試表徵結果,得出本文所製成的- fe _ 2o _ 3基氣敏元件的氣敏機理特徵屬于表面控制型。
  12. Fully developed blood vessels are not sensitive to oxygen toxicity

    充分發育的血管對氧中毒是不敏感的。
  13. Sfsz - zro2 has sensitive electric property parameter and is used for making oxygen sensors, oxygen detectors, the fuel cell of third generation and high - temperature heater

    具有敏感的電性參數,是製作氧傳感器、氧探測儀、第三代燃料電池和高溫發熱體等的主要組成份。
  14. ( 4 ). the application of oxygen sensitive materials in fiber optical dissolved oxygen sensor was studied : the respond time is 20s and the repeatability and stability are excellent. the detection of the sensor is not affected by ph value, but is influenced by the temperature of solution, and only could be used in low - temperature solution for detection

    ( 4 )氧敏感材料在光纖溶解氧傳感器中的應用:該傳感器的響應時間為20s ,重復性和穩定性較好,不受溶液ph值的影響,但受水溫影響較大,只能用於低溫溶解氧的檢測。
  15. Plastic substrates with multi - layer coatings for the flat panel displays were introduced, they were sufficiently impermeable to moisture and oxygen for application to moisture - sensitive display applications, such as lcd, organic light emitting displays ( oled ) and poly oled ( polymer oled )

    摘要介紹了具有多層塗膜的塑料基片,它們對于潮氣和氧具有足夠的不可滲透性,可用於對潮氣靈敏的顯示器,譬如lcd ,小分子有機半導體發光二極體顯示器和聚合物半導體發光二極體顯示器。
  16. It is evident from the equation that the sensor will be most sensitive to low levels of oxygen

    從等式上明顯看出傳感器對低水平的氧更靈敏。
  17. The lhcii, which lies outside, was digested partly in both naci - washed psil particle binding the 33 kd protein and caci2 - washed psil particle lacking the 33 kd protein, independent of binding of 33 kd protein. however, caci2 - washed psil particle was more sensitive to tryptic attack than naci - washed psil particle, especially, cp43 decreased more significantly in caci2 - washed psil particle than in naci - washed psil particle. oxygen - evolving psil core complex was sensitive to trypsin digesting, cp43, d2, d1 and 33 kd protein were digested even under slight trypsin treatment and the fragment were verified by western blotting

    結果顯示:在nacl鹽洗ps顆粒和cacl _ 2處理ps顆粒中, lhc容易被酶解; cacl _ 2處理ps顆粒比nacl鹽洗ps顆粒對胰蛋白酶作用敏感;與nacl鹽洗ps顆粒相比,在除去33kd蛋白后, cacl _ 2處理ps顆粒的cp43更容易被酶解;放氧核心復合物對胰蛋白酶更敏感,在低濃度的胰蛋白酶作用下, cp47不被水解,而cp43 、 d _ 2 、 d _ 1和33kd蛋白被部分水解, western - blotting可以檢測到它們的水解片段。
分享友人