plasma measurement 中文意思是什麼

plasma measurement 解釋
等離子體測量
  • plasma : n. 1. 【生理】血漿;淋巴液。2. 【生物學】原生質。3. (做藥膏用的)膏漿。4. 【礦物】半透明的綠玉髓。5. 【物理學】等離子(體);等離子區。
  • measurement : n. 1. 測量,計量,量度。2. 份量,尺寸,大小,寬度,厚度,深度(等)。3. 測量法。 measurement goods (按體積、容積計算的)體積貨物。
  1. The structures and characteristics of several graphite samples are measured by means of powder x - ray diffraction ( xrd ), brunauer - emmer - teller ( bet ) surface area measurement, inductively coupled plasma ( icp ) spectroscopy, particle size analysis and electrochemical measurements. the effects of origin, structure, impurity, particle size, specific surface area of carbon materials on the electrochemical characteristics are studied. a synthetic graphite with abundant resources, low cost and favorable performance is determined as the raw material for modification of graphite

    採用xrd 、 bet 、 icp 、激光粒徑分析及電化學性能測試等方法,對國內外多種典型石墨樣品的結構與性能進行比較,研究石墨材料的來源、晶體結構、雜質含量、顆粒大小、比表面積等因素對其充放電性能的影響,確定一種性能較好、價格低廉、來源廣泛的普通人造石墨粉作為熱處理與摻雜改性、以及復合結構炭材料研究的原材料。
  2. Haemostaseology - determination of thromboplastin prothrombin time - part 1 : reference measurement procedure for the determination in plasma from citrated venous blood

    止血學.促凝血酶原激酶時間的測定.第1部分:測定含枸
  3. By film thickness measured, fourier transformed infrared spectrometer ( ftir ) analysis, x - ray photoelectron spectroscopy ( xps ) analysis and relative irradiance measurement, the effect of microwave input powers on deposition rates, f / c ratios, bonding configurations of ct - c : f films and the radicals in plasma originating from source gases dissociation is analyzed

    由於微波功率的改變會導致等離子體中電子溫度和等離子體密度發生變化,從而造成不同的源氣體分解過程,結果微波功率的升高導致了薄膜沉積速率的提高、 f / c比的降低,同時也導致薄膜中cf和cf _ 3基團密度的降低,而保持cf _ 2基團密度接近常數。
  4. Practically, we designed a laser differential interferometer system for dense plasma density measurement

    建立了適合於稠密等離子體測量的激光剪切差分干涉測量系統。
  5. Theoretically, using the theory of mutual effect between laser and plasma, the rule of laser propagating in plasma, and the principle of differential interferometry, the basic model of differential interferometry for plasma density measurement was built

    理論上,運用激光與等離子體的相互作用原理、激光在等離子體中的傳播規律、以及差分剪切干涉測量技術原理,建立了使用差分干涉技術測量稠密等離子體密度的基本模型。
  6. The common path defocusing 4f shearing interferometer in the system was constructed, which is fit for the dense plasma measurement. the advantages of this system consist in its stability and easy adjustment as the common path system and respective adjustability of shearing amount and stripe spatial frequency as m - z interferometer as well

    設計了基於共光路結構的離焦4f剪切差分干涉儀,該干涉儀同時具有m - z型干涉儀的剪切量和條紋空間頻率分別可調的優點以及共光路結構的穩定性和易於調節的優點,使得在稠密等離子體的測量中,系統參數可以兼顧小的剪切量和大的條紋空間頻率。
  7. In this thesis, the mechanism analysis and numerical simulation on the coupling flow field of microwave plasma within resonant cavity of mpt was discussed and the subsystem of small thrust measurement as well as the vacuum experimental study of mpt were completed

    在航天飛行器上有廣闊的應用前景。本論文對mpt微波等離子體耦合流場進行了機理分析和數值模擬,建立了mpt的小推力測量系統,協同進行了mpt真空環境實驗研究。
  8. Numerical simulations were done to show the distortion of the wavefront and the interference pattern under several kinds of typical plasma density distributions. the ray path in plasma was calculated by the numerical solution of the vector equation of light ray, when the plasma density was closing to the critical electron density of the laser frequency. through the simulations, the factors that influence the measurement were found out under different density distributions and shapes of plasma

    在此基礎上,採用數值模擬的方法,計算了在幾種典型的等離子體密度分佈下,激光波面的變化和產生的干涉圖樣;並用光線矢量微分方程的數值解法計算了當等離子體密度接近光頻臨界電子密度時,光線在等離子體中的傳播路徑,從中掌握了在不同的等離子體密度和形狀下,進行干涉測量所應估計到的因素。
  9. Nuclear energy - measurement of radioactivity in the environment - water - part 2 : measurement of the concentration of uranium in water by inductively coupled plasma atomic emission spectroscopy

    核能.環境中放射性的測量.水.第2部分:感應耦合等離子體原子發射光譜法測量水中鈾的濃度
  10. It ' s detailed desires is to rebuild microwave interferometer for projectiles ionized wake measurement to get a new one which is easy to operate and whose outcome is correct. in chapter 1 the significance of making a diagnosis in plasma is given, especially in projectiles ionized wake diagnosis

    氣動物理靶中的超高速飛行物的尾跡與一般的等離子體有共性又有不同點,所以在第一章緒論里主要講述等離子體診斷,特別是氣動物理靶尾跡的診斷的重要意義。
  11. Multimedia systems and equipment - colour measurement and management - part 5 : equipment using plasma display panels iec 61966 - 5 : 2000 ; german version en 61966 - 5 : 2001

    多媒體系統和設備.顏色測定和管理.第5部分:使用等離
  12. Take a photograph of devices hav developed from dante spectrometer to soft x - ray str eak camera ( at ~ 20ps ) in which one has a chance to investigate a good many plasma phenomenon. measurement of the time - varying spectral shape of the soft x - ray continuum from laser - fusion targets can provide a detailed dynamical record of x - ray processes important to the understanding of thermal conditions in such experiments

    自從六十年代末到七十年代初以來,應激光聚變實驗研究的需要,軟x光時間分辨診斷技術有了長足的發展,攝譜裝置由以前的dante譜儀到現在的軟x光條線相機, ( t 20ps ) ,通過這些裝置,可以有機會驗證諸多等離子體現象。
  13. The development of automatic measurement system for laser plasma shock wave

    激光等離子體沖擊波自動測試系統的研製
  14. Haemostaseology - determination of thrombin time - part 1 : reference measurement procedure for the determination in plasma from citrated venous blood

    止血學.凝血致活酶時間的測定.第1部分:測定含枸櫞酸
  15. In the experiment, we measured the same material in different size situation, and proved the measurement has good duplication. and also we measured the plasma in even situation and the plasma which is even in axial but has a gauss distribution in radial direction

    實驗中,對同種材料在不同尺寸情況下進行了測量,證明了測量方法的正確性和良好的重復性。並且對等離子體在均勻情況和軸向均勻而徑向具有高斯分佈情況進行了計算,取得了滿意的計算結果。
  16. Multimedia systems and equipment - colour measurement and management - equipment using plasma display panels

    多媒體系統和設備.顏色測量和管理.使用等離子體展示板的設備
分享友人