pump amplitude 中文意思是什麼

pump amplitude 解釋
泵頻信號振幅
  • pump : PUMP =politically upwardly mobile personality 政治新星,政治上有望晉升人士。n (淺口無帶的)輕舞...
  • amplitude : n. 1. 廣闊,廣大。2. 豐富,充足。3. (思想的)廣度。4. (天體出沒時偏離正東或正西的)角度距離。5. 【物,電】振幅。
  1. The carrier wave is modulated directly by the baseband signal at several frequency point in l band and s band. firstly, this paper clarifies the theory of i / q modulation, elaborates evm and acpl, and analyzes the effect of amplitude and phase unbalance and dc offset on evm. secondly we review the basic principle of phase locked loop and it ’ s composing parts, including the basic conception and design method of pll frequency synthesizer, especially introduce the charge pump pll frequency synthesizer in detail

    首先,在闡述i / q正交調制基本原理的基礎上,通過對誤差矢量和鄰近通道功率泄漏的詳細分析,定性、定量地討論了各種非理想電路因素(如相位不平衡、幅度不平衡、直流偏差等)對調制器性能的影響;其次,介紹了鎖相環的工作原理和基本組成部分,包括鎖相環的設計和環路濾波器的設計,特別詳述了電荷泵鎖相頻率源;第三,介紹了採用直接調制技術模擬衛星信號的射頻前端的設計;最後,對整個直接射頻調制系統進行測試,結果基本上達到了課題要求。
  2. Statistics and analysis of amplitude domain parameters of the vibration acceleration signal measured during closing of the pump valve shows that, by using this diagnosis method, the feature information of the pump valve failure can be extracted effectively, and the failure information features are rather obvious

    通過對測取的三缸泵閥箱上泵閥關閉過程振動加速度信號的幅值域多參數的統計分析證明,採用振動信號幅值域多參數診斷法可有效提取泵閥失效故障的特徵信息,且故障信息特徵非常明顯。
  3. By adopting the vibration signal amplitude domain multi - parameter diagnosis method, the troubles of the valve on a triplex pump can be recognized accurately

    採用振動信號幅值域多參數(如峭度指標、裕度指標和脈沖指標等)診斷法,可較準確地判別三缸泵泵閥的故障。
  4. We discuss the effect on the focusing of the probe beams for the five initial parameters : the amplitude of the pump beam, the separation between the pump and the probe beam centers, the wavelength ratio of the pump and the probe beams and the ratio of the initial beam widths at the directions of x and y. our numerical results show that, more the amplitude of the pump beam, the wavelength ratio of the pump and the probe beams and the ratio of the initial beam widths at the direction of y, more the probe focus ; the separation between the pump and the probe beam centers and the ratio of the initial beam widths at the direction of x have optimum values, respectively

    研究了泵浦光束輸入振幅、泵浦光束-信號光束初始偏移、泵浦光束-信號光束波長比和泵浦光束-信號光束x 、 y方向的初始束寬比五個參量對信號光束聚焦程度的影響。數值模擬結果表明,泵浦光束輸入振幅越大、泵浦光束-信號光束波長比越大、 y方向束寬比越大,信號光束聚焦程度越大;泵浦光束-信號光束初始偏移和x方向初始束寬比都存在一個最佳值,使得光束聚焦達到最佳效果,有趣的是這兩個最佳值的比值基本保持不變約為0 . 4 0 . 6 。
  5. As an example, we studied the co - propagation of two soliton beams with one ' s amplitude is much stronger than another. it is then found that the weaker ( probe beam ) can experience a very large phase shift within a rather short propagation distance by modulating the input power of the stronger ( pump beam ). chapter 3, nnlse is simulated for two beams propagation

    以振幅一強一弱共同傳輸的孤子光束為例進行了具體研究,相位分析顯示,與局域孤子相比,孤子光束在相當短的傳輸距離之內能產生大的相移,可以通過對強光(泵浦光)能量的調控來實現對弱光(信號光)的相位調制。
分享友人