ratio calibration 中文意思是什麼

ratio calibration 解釋
比例校準
  • ratio : n. (pl. ratios)1. 比,比率,比值;比例;系數。2. 【經濟學】復本位制中金銀的法定比價。vt. 1. 用比例方式表達;求出…的比值;使…成比例。2. 將(相片)按比例放大或縮小。
  • calibration : n. 1. 測定口徑。2. 刻度,標度,劃度數。3. 校準;標準化。
  1. A camera calibration method with co - line points is proposed, in which distortion center is located according to cross ratio invariability, and then distortion coefficients are calculated based on a line ' s central projection is a line

    摘要提出一種用共線點列標定攝像機鏡頭畸變參數的方法,先根據交叉比不變性確定畸變中心,再利用直線的中心投影仍為直線這一性質確定畸變系數。
  2. In the self - calibration scheme, the thesis emphasizes the accuracy of camera intrinsic and extrinsic parameters. we presents an accurate f method based on corresponding point adjustment. the method adjusts coresponding points according to the fixedness of projective transformed cross ratio, then calculates f matrix accurately through linear and non - linear methods. when computing intrinsic parameter, a matrix, we simplify the step, and stress on the two important parameters of a. the result will be getten through solving kruppa equation based on svd decomposition. in order to compute extrinsic parameters, we use linear method to get initial r and t, then apply non - linear method to accurate them

    提出了基於匹配點調整的f求精方法,先根據攝影交比不見性對手工選擇的匹配點進行調整,再用線性、非線性結合的方法求精f矩陣;在計算內部參數a中,進行了一定的簡化,把重心放在a中重要的兩個參數上,用svd分解法計算kruppa方程;在計算外部參數時,首先用線性法求解r 、 t ,然後再用非線性法迭代求精。
  3. The dissertation is mainly including four section : the first is the experiments done in the tank, which will supply the reliable information of imaging data ; the second is image edge detection by the use of the art of the zernkie moments, which is used to detect the liner and threaded edge of the object, the third is the underwater camera calibration technique, the forth is automatic positioning the location of the camera by used of the art of cross - ratio, the result of which is satisfied

    本文工作分為四個部分:第一部分是水槽實驗部分,它為后續的工作提供了可靠的圖像數據信息;第二部分是基於zom距的直線、曲線邊緣提取技術及相關的與處理技術;第三部分,水下攝像機標定技術研究,基於改進的tsai演算法,採用逐步分解的標定策略。並探討了一種相對簡單的、靈活的標定技術;第四部分是攝像機定位技術研究,採用具有平移不變性的交比進行攝像機定位,模擬試驗的最大誤差不超過2 ,效果還是令人滿意的。
  4. The main contents are as followings : ( 1 ) the rules of choosing characteristic lines of fe and ni elements in the cu - pb alloy are investigated ; ( 2 ) the characteristic line of the impurity element and that of the reference element makes up a line pair. the intensity ratio of the line pair measured as an y - axis and the corresponding concentration ratio as x - axis, calibration curves for composition analysis is fitted at the 4 kinds of buffer gases

    Q )採用內標法,由樣品中雜質元素的分析線和內標元素參考線組成分析線對,對五種不同的鉛黃銅樣品,實驗通過測定了雜質元素分析線隊的強度比,以分析線對的強度比為縱坐標、分析線對所對應元素的含量比為橫坐標,擬合出了一系列在四種緩沖氣體中的定標曲線。
  5. Ratio current amplifier and its application in the calibration for mini - current transformer

    比例電流放大器及其在微電流互感器校驗中的應用
  6. As the requirements of its function, a bus control interface board has already been designed. also the paper have provided the scenarios demonstration for the bus control interface board ( bcib ), the design for the protocol of communication, the hardware for bcib, the software for bcib, and the software for the processor ' s communication. while the analysis for the capability of real - time and the calibration and test for subsystem have been also finished. during the design, the system advanced ability, reliability, resources availability and the cost - efficency ratio are considered. the issus such as system integrated control, mutual exclusion of the shared storages, generation of handshaking signal and system self - test were resolved

    本論文主要對航空自衛系統的綜合化方式進行了深入研究,並按其功能等方面要求,對航空自衛系統綜合化總線通信模塊進行了設計,主要完成了總線通信模塊方案論證、通訊協議設計、總線通信模塊硬體設計、總線通信模塊( bcib )軟體設計、處理機通信軟體設計、實時性分析、系統調試、試驗等項工作,在設計過程中,綜合考慮了系統先進性、資源利用率、費效比及可靠性等因素;重點解決了系統綜合控制方式、共享存儲器互斥、握手信號產生及系統自檢測等問題。
  7. It is shown that the results of single - calibration - ratio iteration calculating method is better than the single - calibration ratio method and are comparable with kf method and gas - pressure method

    實驗結果表明,經過改進的氣相色譜單點校正因子迭代法明顯優于單點校正因子法,與卡爾費休滴定法、氣壓法測定結果有可比性。
  8. The analysis results of single - calibration - ratio method, single - calibration - ratio iteration calculating method, karl fisher ( kf ) method and gas - pressure method were compared based on a series of waterborne samples

    用改進后的氣相色譜法測定了16個水性塗料樣品的水含量,對單點校正因子法、單點校正因子迭代法、卡爾費休滴定法、氣壓法測定結果進行了比較。
  9. So it is sure that the electrical quantity transducer calibration device with high performance - price - ratio will bring fresh vigor to the design, production and market of the related industry

    可以預見,具備優異性能價格比的智能電量變送器校準裝置,將給本行業的設計、生產和市場競爭注入巨大的活力。
  10. In this dissertation, researching from the basic concept of large signal network analysis, we discuss the measurement theory and technology of rf network nonlinearity and the characterization technology of intermodulation distortion in detail, and analyse some nonlinear characteristic excited with a one tone or multi - tone, such as am - am, harmonic distortion, intermodulation distortion, adjacent channel power ratio and how to qualitatively analyse nonlinearity of rf network to make the measurement and calibration

    本課題從大信號網路分析的基本概念出發,詳細討論了射頻網路非線性的測量理論和技術以及互調失真表徵技術,分析了在單頻音和多頻音信號激勵下的一些非線性特性,如am - am , am - pm ,諧波失真,互調失真( imd )和臨近通道功率比( acpr )等,以及根據包絡域方法定性地分析射頻微波網路的非線性特性,以此來進行射頻網路的非線性測量和校準。
  11. Inductive voltage dividers ( ivd s ) will be calibrated by comparison with the laboratory s 8 - dial ivd, normally at specific frequencies of 400 hz, 1 khz and 10 khz with an input test voltage of 25 v. the calibration normally involve measurement of voltage ratio ( magnitude ) of the output voltage related to the input voltage of the ivd

    感應分壓器一般按400hz 、 1khz及10khz等指定頻率及25v的輸入測試電壓,透過與本所的八刻盤感應分壓器對比而進行校正。校正工作一般包括測量該感應分壓器輸入電壓與相對輸出電壓的電壓比(幅值) 。
  12. The basic calibration for a single decade ivd will include measurement of voltage ratio for all output settings of the ivd at one test frequency

    一個單盤感應分壓器的基本校正工作包括按一測試頻率,測量該電感分壓器所有輸出定位的電壓比。
  13. The basic calibration for a multi - decade ivd will include measurement of voltage ratio at one frequency for all separate settings of the first and second dials of the ivd

    一個多盤感應分壓器的基本校正工作包括按一頻率,測量該感應分壓器的首個及第二個刻盤所有分開定位的電壓比。
  14. In this paper, the single - calibration - ratio iteration calculating method is proposed to improve quantitative analysis method for determination of water in water - reducible paint by gas chromatography ( gc ) and some procedures in experiment are modified

    摘要本文提出單點校正因子迭代法,改進了氣相色譜測定塗料中水的定量分析方法,並對部分實驗操作步驟進行了改進。
  15. Calibration specification for sets of voltage ratio standards at power frequency

    工頻電壓比例標準裝置校準規范
分享友人