tap changer 中文意思是什麼

tap changer 解釋
抽頭變換器
  • tap : vt 1 輕打[拍,敲]。2 補鞋底,打鞋掌;打(著做)出〈如用發報機打出電訊〉。3 選舉,選擇。vi 輕敲,...
  • changer : n. 變更者;更換器;(電唱機)自動換片器。
  1. In this dissertation, correlative research of longer - term voltage stability have been carried out, including some slow dynamic elements, such as on - load tap changer ( oltc ), maximum excitation limiters ( mel ), etc. the effects of these slow dynamic elements on the course of voltage instability or collapse are revealed from the point of view of time - domain simulation

    本文基於pss e程序中的擴展動態模擬模塊,對考慮有載調壓變壓器( oltc ) 、最大勵磁限制器等慢動態元件的中長期電壓穩定進行了相關的研究,從時域模擬的角度揭示這些慢動態元件在電壓崩潰過程中所起的作用。
  2. Comprehensive identification and field treatment for common faults of load tap changer of power transformer

    基於概率神經網路的電力變壓器故障診斷
  3. First the paper use the different four network operating condition as the primary given conditions and set the 330 / 220kv transformer tap changer position in the standard position, adding the paralleled capacitor bank sets one by one into the network to change the amount of the input reactive power, thus obtained four sets of the 330kv and 220kv bus voltage and the active and reactive power losses changing curves

    進而研究了在每一確定並聯補償電容器組投入量條件下,隨聯變調壓檔位變化而產生出的一組並聯補償量、母線電壓與損耗的變化曲線。進而選出了隴南電網在四種選定電網運行方式下、有功損耗最小條件下的最優綜合控制組合曲線。
  4. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及電網潮流,總結出了如下規則:隴南電網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償電抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內無功潮流分佈合理、各變電站母線電壓在理想的范圍內時電網有功損耗最小,從而也提高了電網安全運行水平及供電質量。
  5. Main functions : 3 - stage complex - voltage blocked overcurrent protection, 3 - stage zero - sequence overcurrent protection, clearance discharging zero - sequence overcurrent protection, zero - sequence overvoltage protection, overvoltage alarming, overload alarming, fan start stop, tap changer blocking, pt wire broken blocking and alarming, etc

    其保護配置:復合電壓閉鎖過流段保護,零序過流段保護,間隙放電零序過流保護,零序過壓保護。
  6. Based on examples, the problems in reinstallation process of oil pump, tap - changer and bushing after transformer maintenance overhaul are analyzed. the measures to prevent the problems are presented

    摘要以實例分析了變壓器大修后潛油泵、無勵磁分接開關、套管回裝過程中存在的問題,提出了防止類似問題發生的措施。
  7. The study bases on the four operating conditions of which the longnan network will be implemented in the year of 2005 and 2010. first, this paper calculates the power flow distribution that including the line charging reactive power and input of the low - voltage shunt reactor in chengxian s / s. assumed that the bus voltage of tianshui s / s and bikou power plant to be constant, the study count the voltage level of the 330kv and 220kv bus - bar when the 330 / 220kv transformer in standard tap changer position. in order to set control rules

    本文基於隴南電網在規劃發展水平年2005年及2010年的四種可能的運行方式下及潮流條件,計算出了計入線路充電無功及投入成縣變低壓並聯電抗器后的潮流分佈,在設定甘肅大網側及碧口電廠側母線電壓恆定條件下,計算了330kv及220kv主變在有載調壓標準分接頭變比下的330kv及220kv母線電壓水平。
  8. The transformer that use solid state relay to realize automated regulation is explored in this issues, it change the winding turn of once side according to the voltage of second side by on - load tap - changer. thus the purpose to realize automatic steady voltage

    本課題研製的應用固態繼電器實現的有載自動調壓變壓器,通過自動有載調壓分接開關根據變壓器二次側的電壓自動改變變壓器一次側的匝數,從而實現自動穩壓的目的。
  9. In order to ensure the whole system operate economically, power department equip transformer with onload tap changer and shunt capacitors for most distribution substations, according to the operating condition, adjusting the position of transformer taps and capacitors can control the variation of voltage and reactive power exchanger of distribution substations and power system in certain extent

    為確保整個系統運行經濟性,降低網損,電力部門在大多數變電站配置了有載調壓變壓器和並聯補償電容器組,根據運行情況適當調節變壓器分接頭的位置和投切並聯補償電容器組,可以降低電壓變化和變電站與系統的無功交換控制在一定的范圍內,確保供電質量和電網運行的經濟性。
  10. This thesis carries out studies aiming at the impact of load characteristics and on load tap changer on voltage stability

    本文針對負荷特性和有載調壓變壓器對電力系統靜態電壓穩定性的影響展開研究。
  11. Transformers ; three - phase oil immersed type power transformers with off - circuit tapchanger or with on - load tap - changer 2000 to 10000 kva for 50 hz and u up to 123 kv ; characteristics

    變壓器.裝有斷路分接頭切換或帶載分接頭換接的50hz
  12. The tap - changer is made with solid state relay as its working mechanism and controlled by microprocessor. this switch has totally cancelled the mechanical drive organization, by the microprocessor according to the voltage of second side microprocessor decide the working condition of solid state rely, high regulation speed, need not transition resistor, rush current is low. operating frequently ; there is no electric arc to produce, can put in the fuel tank of the voltage transformer directly ; the structure is simple, the fabrication cost is low, benefit and use widely among the voltages transformer of distribution

    其中的有載調壓分接開關,它是一種完全由固態繼電器作為分接開關執行機構,由單片機控制的有載自動調壓的變壓器分接開關。該開關完全取消了機械傳動機構,由單片機根據變壓器二次側電壓的高低,決定與變壓器各分接頭聯接的固態繼電器的工作狀態。調節速度快,改變分接頭時不需過渡電阻,沖擊電流小,可頻繁操作;無電弧產生,可以直接放在變壓器油箱中;結構簡單,造價低,便於在配電變壓器中推廣使用。
  13. Though standard cast resin dry - type transformers can meet the demands of most consumers. we still have to proceed special designing of transformers for special application field and operating conditions, such as single phase transformers, regulating transformers with onload tap changer, double voltage transformers, isolating transformers, rectifying transformers, earthing transformers and transformers with special tapping arrangement, which we are supplying to consumers all over the country

    雖然標準的樹脂絕緣乾式變壓器已能滿足大多數用戶的要求,但是對于某些特殊的應用領域與使用條件仍需我們進行特殊設計。諸如單相有載調壓雙電壓變換隔離整流接地以及有特殊出線排列的變壓器,我公司在不斷地提供給各地的用戶。
  14. Making use of the idea of the parallel genetic algorithms, presenting the adaptive multiple subpopulation evolutive strategy. presenting extinction and immigration strategy in order to avoid the similar or even same individuals appear. in order to enhance convergence velocity of reactive power optimization of the radial distribution system, combining the characteristic of the radial distribution system, a sensitivity analysis approach was build up for optimal selection of capacitors and mutation of transformer tap changer

    為了提高配電網無功優化的收斂速度,結合配電網的特點,提出採用簡單可行的靈敏度公式選擇無功電容補償器的安裝地點,並用靈敏度分析變異變壓器分接頭,使變異運算元的選取更符合配電網無功優化問題中關于調節變壓器分接頭的實際情況,減少了一些不必要的變異運算,使適應性和魯棒性加強;根據實際情況採用無功補償電容器的啟發式變異,使變異運算元的選取更符合無功優化問題中關于補償電容器的實際。
  15. Microcomputer automatic measuring system for on - load tap - changer

    有載分接開關微機自動檢測系統
  16. The design, material and technique of on - load tap - changer in main transformer are introduced

    摘要介紹了主變有載分接開關在設計、材料和工藝上的改進。
  17. Aiming at the impact of electric network fluctuation on frequency diverter, it provides countermeasures in aspects of expanding electric network capacity, technical reformation, electric network filtering, applying on - line tap changer and uninterruptable power supply, and modifying frequency inverter parameter setup

    針對電網波動對變頻器運行造成的影響,從電網擴容與技術改造、電網濾波、採用有載調壓變壓器和不間斷電源、修改變頻器參數設置等方面提出了相應的措施。
  18. The quantity type and fault of the lead tap changer ( oltc ) used inhubei 110 kv and higher power network are investigated. based on investigation, the measures to prevent failure are presented, which will promote the safe operation of oltc

    對湖北電網中的有載分接開關數量、型式、故障情況進行了全面的調查,提出了防止事故的措施,以促進有載分接開關的安全、可靠運行。
  19. In addition, the tap changer auxiliary controllers for converter transformers are preliminarily studied

    另外,對換流變壓器的分接頭輔助控制器的建模問題進行了初步探索。
  20. It shows that the action of on - line tap changer in the load bus has an important influence on the voltage stability of the system

    模擬結果表明,負荷節點處的oltc調節對系統的電壓穩定性有較大的影響。
分享友人