terminal resistance 中文意思是什麼

terminal resistance 解釋
端子抵抗值
  • terminal : adj 1 終端的,終點的,結尾的;極限的。2 定期的,每期[季]的;每學期的,學期終[末]的。3 期終的;末...
  • resistance : n. 1. 抵抗,反抗,抗拒,抵禦;敵對,抵抗力,反抗力,阻力,【生物學】抗病性。2. 【電學】電阻;阻抗;電阻器。
  1. By the check - out, inspection and measurement to start construction the industrial art to this test pile with the examination between stake body mass and bearing power, made sure the stroke reasonable operation method drilling under the dissolved cavern geology term ; the pier foundation loading test expressed the lading and rub the lading that resistance drag a glazing for of relation, and to the borehole cast - in - place concrete pile in the karst terrain deliver with break the mechanism, the characteristic of bearing power, proceeding the spot test job of the full of result ; the test data expresses the stake side friction resistance to rises with a bat batch terminal friction resistance very important function, the of tip of pile resistance drag occupies the proportion very few

    通過對本次試樁施工工藝的檢測和樁身質量及承載力的檢驗,確定了沖擊鉆在溶洞地質條件下的合理使用方法;基樁承載實驗表明了荷載與摩擦阻力之間的關系,並對巖溶地區的嵌巖灌注樁的荷載傳遞和破壞機理、承載力特性,進行了富有成果的現場測試工作;試驗數據表明樁側摩阻和支盤端阻起很重要的作用,樁端阻力所佔比例甚少。這與設計樁基時的計算模式相差很大,承載力也較設計增加;使用力學數值分析方法和有限單元法,對鉆孔灌注樁樁端下的巖體強度和結構穩定性方面進行模擬計算和定量研究。
  2. Then, this thesis presents an algorithn of 2 - terminal quantity fault location based on synchronous gps sampling. this algorithm conducts fault location with only the 3 - phase fundemental wave voltage and current phasors of the 2 terminals of transmission lines and apples to lines of both symmetrical and asymmetrical parameters, irrelerant to the impedence, fault types and transitional resistance of the 2 terminals of lines

    然後,本文提出了一種基於gps同步采樣的雙端量故障測距演算法。該演算法僅利用輸電線路兩端的三相基波電壓、電流分量來進行故障定位,不受線路兩端系統阻抗、故障類型、過渡電阻等因素的影響,對參數對稱線路和非對稱線路均適用。
  3. Because affected by the type of lines, fault resistance and two sides systems , fault analytical location has lower precision, but it has no dead line and is more better accurate if the fault location is close to the line terminal

    故障分析法由於受線路類型、過渡電阻、兩端系統的影響測距精度較差,但故障分析法不存在測距死區,尤其對近區故障的測距較為準確。
  4. Department perfect test, which can be made into various mechanical properties such as : tension tests, strength tests slide, terminal testing ; electrical performance test items include : insulation resistance testing, contact resistance testing, testing withstand voltage, high and low test, solderability test, durability testing, vibration - resistant testing, life test

    完善之測試部,能作各項機械性能測試如:拉力測試、插撥力測試、端子強度測試;電氣性能測試項目計有:絕緣電阻測試、接觸電阻測試、耐電壓測試、高低測試、可焊性測試、耐久性測試、耐振測試、壽命測試等
  5. Designers and registered electrical workers may be uncertain whether conductive parts such as metallic bathroom accessories, metallic windows or metallic door handles are extraneous conductive parts. when difficulties are encountered, you may carry out a measurement as illustrated in figures 4 and 5. in figure 4, a is an exposed conductive part with a resistance rcpc to main earthing terminal

    附圖四載列外露非帶電金屬部分a及懷疑為非電氣裝置金屬部分b (例如是金屬水喉管或木門的金屬手柄) , a對總接地終端的阻抗為rcpc , b對地的阻抗為rx 。
  6. Remember the following words and expressions : e. g. multimeter ; circuit , current ; voltage ; resistance ; digital multimeter ; analogue multimeter ; analogue multimeter scales ; zero adjustment control ; zero adjustment control for resistance ranges ; measurement ranges switch ; transistor test socket ; meter probe ; positive terminal ; negative terminal ; anode ; cathode ; red lead ; black lead ; power supply ; connect in parallel ; connect in series

    記住萬用表、電路、電流、電壓、電阻、數字萬用表、模擬萬用表、表頭、機械零位調整器、歐姆零位調整器、量程選擇開關、晶體管插孔、表棒、正接線端、負接線端、陽極、陰極、紅導線、黑導線、電源、並聯、串聯等常用英文單詞,並逐步掌握。
  7. Terminals table atlantic terminal ul94 - v0 fire retardant material used casting from taiwan, with an outstanding shock resistance and fire retardant

    Idec端子臺採用ul94 v0阻燃材料模鑄而成,具有傑出的阻燃和抗沖擊性能。
  8. Telecommunications - telephone terminal equipment - resistance and impedance performance requirements

    電信.電話終端設備.電阻和阻抗的性能要求
  9. Under this condition, the article elaborates the development and selection of container ship types and propulsion plant for the lines from chongqing, wuhan and nanjing to yangshan deep water container terminal, respectively, based on related knowledge of ship design, ship resistance, marine power plant and ship technical economy analysis

    在此背景下,文中應用船舶設計、船舶阻力、船舶動力裝置及船舶技術經濟論證等相關知識,以規劃中的長江干線航運環境為基礎,探討了重慶、武漢、南京到洋山港航線的集裝箱船船型、動力裝置的開發與優選。
  10. The conventional connection circuit as the figure shows for two - wired transmitter : handhold terminal palm computer and external communication interface or mainframe communication circuit cannot directly bridges in the ends of power source. but may either meet on field ends a and b or meet on the ends of load resistance b and c. in the above - mentioned case, the circuit are supplied by power source

    對兩線制變送器來說,傳統的連接電路如圖所示:手持終端掌上電腦和外接通訊介面或主機通訊電路不能直接跨接在電源兩端,但既可接于現場兩端a , b上,也可接在負載電阻兩端b , c ,兩種情況下,電路都要通過電源來供電, hart規范允許負載電阻為2301100 。
  11. Compared with conventional methods, the proposed method is not disturbed by reflected waves from tee joints or other resistance discontinuities, and is not influenced by fault type, and can recognize the reflected wave from the fault point even when the fault point is near to the measuring terminal ( so - called dead - zone ), and simultaneously, the method reduces the influence of wave speed uncertainty

    與傳統的行波測距方法相比,這種方法不受電纜分支接頭或其他阻抗不匹配點反射波的干擾,不受故障類型的影響,在近區也不存在無法識別反射波的問題,同時也減少了波速不確定性對測距精度的影響。
  12. 6. ground terminal outside must be safely grounded, resistance

    6外接地端子必須可靠接地,接地電阻10 ,拆卸時,應
  13. Because conventional single - terminal method of fault location ca n ' t eliminate the influence of fault resistance and the remote in - feed, its utility is limited

    單端測距法由於存在難以消除過渡阻抗和對端系統阻抗的影響這一缺陷,使其應用受到限制。
  14. Flow regulated by resistance change is apparently uneconomical. in power centralized system, we have to change the resistance to regulate the flow of subcircuit and terminal equipments

    在動力集中系統中,對支路和末端設備的流量調節,採用改變阻力的方式是不得已而為之。
  15. As the requirement of energy - saving and indoor environment gets higher and higher, variable flow technology are widely used in heating and air conditioning systems, namely by changing power or resistance to adjust the flow of the system 、 subcircuit and terminal equipment so as to match usually mutative dynamic heat ( cold ) load variation

    隨著節能和室內環境要求的愈來愈高,供暖和空調系統廣泛採用了變流量技術,即用改變動力或改變阻力的方式調節系統、支路以及末端設備的流量,使之與經常變化的動態熱(冷)負荷相匹配。
  16. The merits of single terminal fault location are its reliability and its accuracy is n ' t affected by the type of line, fault resistance and two sides systems theoretically but this method has problems such as the identification of reflection wave and the unidentifiable area of reflection nearby which are research purpose and core of this paper

    單端行波故障測距方法的優點是其可靠性和精度在理論上不受線路類型、故障電阻及兩側系統的影響,但單端行波故障測距方法存在反射波的識別問題,且在近區還存在無法識別反射波區域。這就是本文的研究目的和中心。
分享友人