three-winding transformer 中文意思是什麼

three-winding transformer 解釋
三繞組變壓器
  • three : n. 1. 三個人[東西]。2. 三歲,三時。3. 【板球】3字型。
  • winding : adj. 1. 卷繞的;繞線的,繞組的。2. 迂迴曲折的,蜿蜒的。n. 1. 卷繞起來的一盤(繩索等);卷繞動作;絡紗。2. 彎曲,紆曲;不正行為。3. 【采】卷揚,提升;【電學】繞組,繞法;線圈。
  • transformer : n. 使變化的人[東西];【電學】變壓器;變換器;互感器。 polarity of transformer 變壓器繞線方向。
  1. In this thesis, the author analyses the deficiency in detecting and controlling function of the computer detecting and controlling system utilized in present transforming station. the strategy of design of software on operation and direction of 5 00kv transformer station is presented. it points out that we can deduce the mathematic analytical formula using the current, voltage and power of two terminals of transmission line as input. on this basis, we do realtime calculation of 500kv transmission line ' s parameter. we can also deduce the linear analytical formula of three - winding autotransformer ' s resistence using its current, voltage and power as input. the corresponding software is programmed on this basis

    論文提出以輸電線路本端和對端電流、電壓、功率作為輸入量,導出了超高壓長線的波阻抗和傳播常數的數學解析式,在此基礎上進行了500kv輸電線路實時參數計算;提出以三繞組自耦變壓器的電流、電壓、功率為輸入量,導出了自耦變壓器繞組的電阻、電抗的線性解析式並進而對變壓器的實時參數進行計算;在此基礎上編制了相應的軟體。
  2. In the models, the iron core nonlinearly of the traction transformer and the magnetic hysteresis effect without the b - h curve are considered. having tested by digital simulation, the winding parameter has not changed in the state of external fault or magnetizing inrush etc. but the winding parameter has obviously changed in state of inter fault or inter - turn fault. ( 3 ) the rules three phases converted to two phases of traction transformer in electric railways are developed in this paper

    ( 3 )利用牽引變壓器磁鏈平衡方程,建立了基於系統辨識理論的雙繞組單相接線牽引變壓器、阻抗匹配平衡牽引變壓器及scott (斯科特)接線牽引變壓器的「灰箱」模型,該模型考慮了牽引變壓器鐵芯非線性和磁滯效應,但又不直接反映在模型中,並且無需鐵芯的b - h曲線數據。
  3. Three - winding transformer

    三繞組變壓器
  4. Principally, when the winding - connection scheme is adopted to add a set of auxiliary windings on the two - phase side of a balance transformer, we can get a three - phase to four - phase transformer

    原則上,在平衡變壓器的兩相側採用增加一套副繞組的雙重接線方案,便可得到三相變四相電力變壓器。
  5. It is the simplest form among transformers in this kind. for evaluating the relationship between the error of winding impedance and the performance of the three - phase to four - phase power transformer, this paper uses “ matlab ” as a digital simulation platform to exam the mathematic model and analyze the balance condition as well as

    因此,本文對不同排列方式,不同回數四相輸電線路的電場、磁場、無線電干擾和可聞噪聲進行了詳細的分析和計算,並把它們與三相輸電線路相應的電磁場參數進行了全面比較。
  6. On the same winding, at most three taps can be made to form four transformer ratios, but the difference between maximum current and minimum current should not exceed one time ( for example : 150 - 200 - 250 - 300 / 5a )

    在同一個繞組上最多可三次抽頭,組成四變比,但最大電流與最小電流相差不能超過一倍(如: 150 - 200 - 250 - 300 / 5a ) 。