  1. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv故障的形式、消弧線圈的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以纜為主的城區10kv網中性點方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際參數來建立數值計算模型,在考慮了流變化、中性點阻取值大小、阻值變化等多種影響因素的情況下,對中性點經消弧線圈和經小方式下網的過壓水平和點短流大小進行了數值計算,其計算結果與科院所作現場試驗進行了比較。
  2. 2 ) tower grounding resistance, distance between towers, etc can affect the function of line - surge arrester

    2 )輸阻,線檔距等因素對線型避雷器的應用有影響。
  3. This project is applied to the control circuit of the frequency converter power source of for measuring ground resistance in an electric substation

    此方案成功應用於變阻測量變頻源控制中。
  4. The breaking and closing of main loop and grounding ioop aer realized by operating device. the speed is determined by the spring, with no regrad to handling speed. the remote inducting and control are available if equipped with automatic instrument

    由獨立於開關的手動或動操動機機構進行主迴的分合和開斷,開關的分合速度由彈簧決定,與手動速度無關,在加裝自動化儀表后,可實現遙感和遙控。
  5. These measures include installation of lightning lines, decrease of the tower grounding resistance as far as possible, the reasonable use of arc suppressing coils and adoption of arresters

    處理方法包括加裝避雷線、盡量減低線桿塔阻值、消弧線圈的合理使用和採用線型避雷器。
  6. In connection with the situation of application of hook type earthing resistance meter in the transmission division of yichang power supply bureau, taking account of the principle and the environmental requirement of measurement, the problems in application were proposed and analyzed as well. according to the different grounding structure of lightning protection for overhead transmission lines, the proper measuring method was suggested

    針對宜昌供局輸分局鉤式阻計使用情況,通過運用該表測量原理和適用條件,分析並提出使用中存在的問題;對架空送防雷構造差異情況,提出正確的測量方法。
  7. Portable equipment for earthing or earthing and short - circuiting for live working

    作業用便攜式裝置
  8. What is the application scope of star bonding ( single point grounding ) and meshed bonding ( multipoint grounding ) networks. what items need to be noted between them

    星狀等位連(單點)和網狀等位連(多點)網的應用范圍是什麼,他們之間需要注意什麼?
  9. During its operation, the rotor of the machine is always under the great suppression of centrifugal force. the surface of rotor is the most important part to enduring the forces and thermal energy. so the windings of rotor are in a common problem of happening one - point to earth short fault, two - point to earth short fault, or turn - to - turn short fault

    汽輪發機是一種高速隱極式同步機,在其運行時,轉子受到強大的離心力的作用,而轉子表面是承受機械應力和發熱的最關鍵的部件,因此汽輪發機轉子繞組容易發生一點、匝間短和兩點故障。
  10. In the 3 ~ 35kv power supply system of our country, the large part is the not solidly earthed neutral system. when the single - phase earthed phenomena happens in this system, this electric power network can run with failure. and in this way the operated cost can reduce greadty. and at the same time the power supply systemic dependability can be improved. but when the single - phase earthed current is large, this electric power system can engender easily arc earthed overvoltage and interphase short circuit by this means

    在我國10 35kv供系統中,主要為中性點非直系統,這種系統在發生單相時,網仍可帶故障運行,這樣可以大大降低運行成本,提高供系統的可靠性,但這種供方式在單相流較大時容易產生弧光壓和相間短,給供設備造成了極大的危害。
  11. Single phase earthed fault is the common fault in this system. to detect the faulty feeder is difficult for the fault current is very small

    單相是最常見的故障,由於它的流較小,使故障檢測較困難。
  12. By analyzing the refraction 、 reflection process of fault transient current traveling wave of high voltage and characteristics of refraction 、 reflection coefficient systematically, a new fault location method of single ended traveling wave is presented. it can not only identify the reflection wave for fault location efficiently, but also not be affected by the structure and length of line. fault earthed resistance 、 fault type 、 system impedance and can locate fault in adjacent areas accurately

    論文深入分析了高壓線故障暫態流行波的波折、反射過程以及折、反射系數的特點,提出了新的單端行波故障測距方法,它不僅能夠有效識別出測距所用的反射波,而且幾乎不受線結構、長短、故障阻、故障類型、系統阻抗的影響,在近區仍可以準確進行測距;同時模擬阻波器的特徵,設計了低通數字濾波器,對通過了低通數字濾波器的暫態故障流行波再次進行小波分析,並利用本文提出的單端行波故障測距方法進行故障定位,結論是所提出的測距方法在實際應用中仍是有效的。
  13. Lwy : what is the application scope of star bonding ( single point grounding ) and meshed bonding ( multipoint grounding ) networks. what items need to be noted between them

    星狀等位連(單點)和網狀等位連(多點)網的應用范圍是什麼,他們之間需要注意什麼?
  14. Coaxial cables used in cabled distribution networks - sectional specification for outdoor drop cables

    纜分佈網中用的同軸纜.室外纜的分規范
  15. When their value increase, the line - surge arrester " action weakens. on the basis of calculation, we fix line - surge arrester on 110kv shuang - han line

    阻增大,線檔距加長,線型避雷器對輸耐雷水平提高的作用減弱。
  16. When their value increase, the line - surge arrester " action weakens. on the basis of calculation, we fix line - surge arrester on 110kv shuang - han transmission line and shuang - hai transmission line

    阻增大,線檔距加長,線型避雷器對輸耐雷水平提高的作用減弱。
  17. When their value increase, the line - surge arrester " action weakens. on the basis of calculation, we fi line - surge arrester on 110kv kang - ping transmission line and 220kv da - an transmission line

    阻增大,線檔距加長,線型避雷器對輸耐雷水平提高的作用減弱。
  18. In addition, the enormous use of cables in city power system increases the current through the grounded capacitor. these make the single - phase fault current get greater, which lead to more and more instantaneous grounding faults unable to eliminate naturally

    近年來,由於城市配規模的不斷發展,以及城網中大量使用纜,使得系統的流大大增加,系統單相故障時弧不能自動熄滅,越來越多的瞬間單相故障不能自動消除。
  19. In recent years, with the large - scale reconstruction of city power system, the scale of power system is continuously expanding, and the power supply network is becoming larger and larger. in addition, the enormous use of cables in city power system increases the current through the grounded capacitor. these lead to more and more instantaneously grounding faults unable to eliminate naturally

    近年來,國家對城市網的大規模改造,使得網的規模不斷發展,配越來越大,加上城網中大量使用纜,使流大大增加,越來越多的瞬間單相故障不能自動消除,為了解決這一問題,我國普遍採用中性點經消弧線圈的補償方式。
  20. Live working - portable equipment for earthing or earthing and short - circuiting iec 61230 : 1993, modified ; german version en 61230 : 1995

    作業.便攜式接地電路設備