換能器校準 的英文怎麼說
中文拼音 [huànnéngqìjiàozhǔn]
換能器校準
英文
transducer calibration- 換 : 動詞1. (給人東西同時從他那裡取得別的東西) exchange; barter; trade 2. (變換; 更換) change 3. (兌換) exchange; cash
- 能 : 能名詞(姓氏) a surname
- 器 : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
- 校 : 校名詞1. (學校) school 2. (校官) field officer3. (姓氏) a surname
- 準 : Ⅰ名詞1 (標準) standard; guideline; criterion; norm 2 (目標) aim; target Ⅱ動詞1 (依據; 依照)...
-
In the digital inverter, we adopt the technology of digital dynamic waveform correction, which can compensate the delay between control signal and output waveform, and ensure the accuracy of control. at the same time, the technology of digital dc component adjustment was introduced, by which we can exactly compensate the control signal, and realize adjusting dc component of output on the premise of output performance
在基於dsp的數字變換器平臺中,採用全數字波形校正技術,完全補償了控制信號延時、功率管開關延時以及死區時間對輸出spwm波形所產生的畸變,充分保障了變換器控制的準確性;採用數字直流分量調節技術,可以精確地對控制信號進行補償,在充分保證輸出性能的前提下,實現了輸出直流分量的調節。Standard test method for calibrating linear displacement transducers for geotechnical purposes
土工技術用途的校正襯墊代替換能器的標準試驗方法The study of this paper indicates that, the combined binarization method can keep details well and tolerate the abominable state ; the method to estimate skew angle based on radon transformation is very exact, and the distortion of corrected image is also very little ; the vlp location method based on wavelet analysis and intensity moment has a high location exactness and a soon processing time ; and intelligent character recognition machine can accomplish the function of self - adaption, self - correction, self - study, etc
本文研究表明:混合二值化方法能較好的保留圖像細節,抗噪聲能力強;基於radon變換估計傾斜角度的方法檢測角度精確,校正後圖像失真較小;基於小波分析和亮度矩的車牌定位方法定位準確率高,速度快;仿人智能字元識別器則能實現識別字元過程中的自適應、自校正、自學習功能等。The system can simulate the transfer process of photo - thermal and thermal - electric at a given parameter setting of structure, environment and circuit. on the basis of circuit structure, the calibration, parameter adjusting and signal readout can be simulated, the vary process of readout circuit, readout voltage, optical gain, optical gain rate, and uniformity can be given. in addition, all kinds of character parameters of device can be forecasted
本論文根據umbirfpa的原理,建立它的軟體模擬系統,它可以根據給定的結構、環境、電路設置等參數首先模擬光熱、熱電轉換過程,並可根據電路結構,模擬校準、參數調節並讀出信號,給出讀出電流和電壓、光學增益、光學增益比、非均勻性等各特徵量的定量變化過程,預測製成后器件的各種性能參數。So to develop a new type of transformer calibrator which has the high precision and the high degree of automation is significative. for the outdated transformer calibrator is widely used, this paper analyzed the theory of previous calibrators and proposed an idea of designing a new type of intelligent calibrator, based on the theory of measure the difference, adopt the project of dsp and mcu structure, also use high speed a / d electric chip. after the design of hardware circuit diagram, adopt the theory of fft and quasi - synchronous sampling method to reach the demand of precision. this paper discuss the intelligent development of transformer calibrator, achieve some success in the study
本文針對國內市場目前普遍使用的老式互感器校驗儀的現狀,提出了智能型互感器校驗的研製思想,並詳細講述了其理論依據和實現過程,提出了切實可行的方案:基於測差測量原理,進行基於dsp和mcu雙cpu架構、並採用高速a / d的硬體電路設計,並在此基礎上採用快速傅立葉變換和準同步采樣演算法,並完成相關的軟體演算法框圖設計,對互感器校驗儀的智能化發展進行了有益的探索,取得了具有實用意義的成果。It is possible that the reflection fringes on the four sides of the acoustic wave screen, after being used for a period of time, are covered by lots of dust, which leads to a failure to adjust. if you use the ka cabinet of our company, you can open the upper cover, and rub with a piece of dry cloth. pay attention not to damage the upper left, upper right and down right transducers
有可能是聲波屏在使用一段時間后,屏四周的反射條紋上面被大量的灰塵覆蓋導致不能進行校準,如果您使用的是我公司ka型機櫃您可以打開上蓋用一塊乾的軟布進行擦拭,注意左上,右上,右下的換能器不能損壞Non - destructive testing - acoustic emission inspection - primary calibration of transducers
無損檢測聲發射檢測換能器的一級校準Practice shows that the instrument has follow characteristics : wids measuring range, high accuracy, intelligence of calibration constant adjustment and zero adjustment, convenience of transducer replacement and easily use, good linearity and measurement error within 0. 5 %
實踐證明:該儀器具有測量范圍寬,測量精度高,校準常數調節和零點調節實現智能化,換能器更換方便和使用簡單等特點,且具有較好的線性度,其測量誤差均在0 . 5 %以內。Vibration measuring technique using laser interferometer for calibration of transducers
用於換能器校準的激光干涉測振技術分享友人