收斂變壓器 的英文怎麼說

中文拼音 [shōuliǎnbiàn]
收斂變壓器 英文
convergence transformator
  • : Ⅰ動詞1 (把攤開的或分散的事物聚集、合攏) put away; take in 2 (收取) collect 3 (收割) harvest...
  • : Ⅰ動詞1 (收起; 收住) hold back; keep back 2 (約束) restrain 3 (收集; 徵收) gather; collect; ...
  • : 壓構詞成分。
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 收斂 : 1 (減弱或消失) weaken or disappear 2 (約束言行) restrain oneself 3 [數學] convergence; constr...
  1. This paper presents a three - phase harmonic power flow algorithm using phase components and back - forward sweep method to solve the disconvergence when the three - phase transformer harmonic model was used. the example result presented the method was feasible and

    本文針對在進行三相諧波潮流演算法時因引入三相諧波模型而可能導致計算結果不問題,提出了諧波潮流計算的相分量法,其中引用了前推-回代法。
  2. As the back - propagation neural network ( bpnn ) is adopted to diagnose the dissolved gases of transformer, convergence rate becomes slow, convergence precision becomes bad and even being out of convergence as more sampled data are trained and more complicated relation between input and output becomes

    根據電力油中溶解氣體分析( dga ) ,採用反向傳播神經網路( bpnn )對電力進行故障診斷時,隨著學習樣本數目的增多,輸入輸出關系的復雜化,網路的速度將得緩慢,精度不理想甚至不
  3. Making use of the idea of the parallel genetic algorithms, presenting the adaptive multiple subpopulation evolutive strategy. presenting extinction and immigration strategy in order to avoid the similar or even same individuals appear. in order to enhance convergence velocity of reactive power optimization of the radial distribution system, combining the characteristic of the radial distribution system, a sensitivity analysis approach was build up for optimal selection of capacitors and mutation of transformer tap changer

    為了提高配電網無功優化的速度,結合配電網的特點,提出採用簡單可行的靈敏度公式選擇無功電容補償的安裝地點,並用靈敏度分析分接頭,使異運算元的選取更符合配電網無功優化問題中關于調節分接頭的實際情況,減少了一些不必要的異運算,使適應性和魯棒性加強;根據實際情況採用無功補償電容的啟發式異,使異運算元的選取更符合無功優化問題中關于補償電容的實際。
  4. This algorithm improves confidence in se by estimating parameters and states at the same time. simulation results on test power systems which range in size from 4 to 118 buses, have shown the virtues as follows : getting unbiased estimation without detecting and identifying bad data in measurements ; solving state and parameter estimation for power system with good convergence and excellent robust property ; increasing the numbers of iterations a little bit with the test systems expanded ; estimating many transformer taps simultaneously and remaining the main state estimation ; keeping the estimated relative error within + 0. 1 % and processing efficiently equality constraints and ill condition with polynomial complexity

    對ieee ? 4 118節點系統和廣西主網進行的模擬結果表明: l1范數估計具有不良數據拒絕特性,當量測量中存在不良數據時,該演算法在不經檢測和辨識不良數據情況下仍是無偏估計,具有良好性,所需迭代次數隨著問題規模擴大而增長極小;能夠同時估計多個抽頭,並保持狀態估計主體;在滿足可觀測性條件下,估計的相對誤差保證在0 . 1以內;能夠有效處理等式約束和病態條件,並具有多項式時間性。