最大電流負荷 的英文怎麼說

中文拼音 [zuìdiànliú]
最大電流負荷 英文
maximum current capacity
  • : 副詞(表示某種屬性超過所有同類的人或事物) most; best; worst; first; very; least; above all; -est
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
  • : 荷名詞(蓮) lotus
  • 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
  • 負荷 : [電學] load; charge; weight
  1. In view of this situation this article has conducted research to the design of metallurgy auxiliary biography with the frequency conversion table electrical machinery first multianalysis to the frequency changer and the frequency conversion table electrical machinery movement characteristic is carried out, the voltage waveform harmonious which the frequency changer outputs is big, attacks in a big way, and the voltage climbing rate reaches as high as 6600v / mu s which is 20 times ordinary sine alternating voltage, the rolling mill auxiliary biography table set the extremely strict request to the electrical machinery ; its movement frequency is very low, rate frequency in 8 - 20hz ; the velocity modulation scope is wide, the lowest movement frequency lowers to 1hz, and the starting number of times is quite frequently, each hour reaches as high as 600 - 800 time, the impact shoulders in a big way, the overload capacity request is high

    針對這一情況本文對冶金輔傳用變頻輥道機的設計進行了系統研究。首先對變頻器和變頻輥道機的運行特性進行詳細分析,變頻器輸出的壓波形諧波,沖擊壓上升率高達6600v / s ,是普通正弦交壓的20倍;軋機輔傳輥道對機提出了十分嚴格的要求:其運行頻率很低,額定頻率在8 - 20hz ;調速范圍寬,低運行頻率低到0 . 5hz ,起動次數相當頻繁,每小時高達600 - 800次,沖擊,過載能力要求較高。
  2. This paper discusses the ability of avoiding maximal power flow of quadrilateral impedance relay and round impedance relay in detail and puts forward the setting principle and setting method of load limiting resistor of backup distance protection

    本文對四邊形和方向圓特性阻抗繼器躲線路的能力進行了詳細分析,提出了距離保護限制阻的整定原則和整定方法。
  3. Taking load uncertainties, infeasibility problem and multiple objection of the reactive power optimization in the radial distribution system into consideration, loads are modeled as fuzzy interval numbers. fuzzy power flow is proposed based on fuzzy interval load for the more practical membership function of line losses rate and maximal voltages offset. this thesis presents multiple objection model of the reactive power optimization considering uncertainties using the fuzzy set theory

    對配壓無功優化問題中的非概率性的不確定性問題、多目標問題、約束不可行性問題進行了研究,用模糊區間來描述實際的情況,並用的模糊區間值計算配網的潮,得到有功功率損耗和壓的模糊區間值,使網損率和節點偏移量的隸屬函數更接近實際情況;將改進遺傳演算法與模糊集理論相結合,通過求解多目標函數和約束條件的模糊集合的交集,得出網損率和節點偏移量小的優運行狀態。
  4. In chapter 3, the subgrid eddy - viscosity model for large eddy simulation is applied to calculate the three dimensions unsteady periodic turbulent flow in yantan francis turbine. the pulsating characteristics of some main physical parameters in flow field are found. the calculated axial water thrust of hydraulic turbine agrees with the model - test value

    第三章採用渦模擬亞格子渦粘模型,對巖灘混式水輪機的場進行三維非定常湍分析,得到了場中各物理量的脈動特性,計算出ms的軸向水推力與模型試驗值小相當;同時論證了對于下機架承重的混式水輪發機組可採用其推力軸承作為水站廠房振動的垂直激振載。
  5. Thus the reactive compensator can be located in the center of the distributed load in the area and make the best user of the compensator ' s capacity. the distance flowed by the reactive current is efficiently reduced and the active loss of power net goes down. two - stage control model is adopted in the optimized control technique of the system

    該系統採用了測量點與補償點與分開的方式,實現了區域性無功監視,使無功補償點可以安置在區域性分散的中心部位,程度地利用了補償容量,有效地縮短了無功傳輸的距離,降低了網的有功損耗。
  6. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷路器所造成的事故無論是在次數,還是在事故所造成的停時間上都占據總量60以上。因此,及時了解斷路器的工作狀態對提高供可靠性有決定性意義;並可以減少盲目定期檢修帶來的資金浪費。本文論述了斷路器機械特性參數監測方法;提出了二次迴路保護器的概念,並將跳、合閘線圈完整性監視和二次迴路保護結合起來,給出具有完整性監視功能的二次迴路保護器實現方案;根據斷路器生產廠家提供的斷路器額定短路分斷次數,計算每次分閘對應的觸頭壽命損耗,預測觸頭壽命;提出根據斷路器殼體溫度和斷路器周圍空氣溫度結合斷路器熱阻來計算斷路器主觸頭穩態溫升的方法,並根據此時的間接計算主觸頭迴路的阻;在硬體路設計上,採用美國ti公司新推出的一種功能強的單片機msp430 ,並充分考慮該晶元的適用壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作壓晶元之間的介面問題,並給出了直接聯接的接線方案。
  7. First, suppose a source point and a sink point. second, draw a unilateral line from source point to every substation node. the line ' s capacity is set as corresponding substation ' s allowable load value and the line cost is set as the substation ' s unit load cost

    本文通過線性化處理后將網架優化模型描述為一個小費用問題,虛擬一個源點和一個匯點,從源點到各變站節點各引一條單向弧,弧容量為變站允許的值,弧費用為變站單位的費用。
  8. To put into operation a large amount of non - linear load, make in harmony wave of rural power grids serious becoming in pollution, pass to rural local electric wire netting main in harmony analysis of wave source, put forward in order to restrain from insert rural power grids in harmony wave source voltage total in harmony wave distortion rate and the containing rate change last device number pulsating for increase of goal, increase the pulse of the current change device and install light specified value electricity active wave filter mix with passive wave filter near the harmonics source to control the wave in harmony

    摘要量非線性的投運,使農村網的諧波污染日趨嚴重,通過對農村地方網主要諧波源的分析,終提出了以限制接入農村網的諧波源的壓總諧波畸變率和各次諧波壓含有率為目標的增加換裝置脈動數,以及在諧波源附近裝設小額定值的力有源濾波器配以無源濾波器的混合型力濾波方式,以進行諧波治理。
分享友人