有功損耗 的英文怎麼說

中文拼音 [yǒugōngsǔnhào]
有功損耗 英文
active loss
  • : 有副詞[書面語] (表示整數之外再加零數): 30 有 5 thirty-five; 10 有 5年 fifteen years
  • : 名詞1 (功勞) exploit; merit; meritorious service [deed]: 戰功 military exploits; 立功 render me...
  • : Ⅰ動詞1 (減少) decrease; lose 2 (損害) harm; damage 3 [方言] (用尖刻的話挖苦人) speak sarcas...
  • : Ⅰ動1 (減損; 消耗) consume; cost 2 [方言] (拖延) waste time; dawdle Ⅱ名詞1 (壞的音信或消息) ...
  • 有功 : have rendered great service; have performed meritorious service
  • 損耗 : 1. (損失消耗) loss; wear and tear; deterioration; waste 2. [商業] wastage; spoilage
  1. Reactive power optimization is of great impotae to voltage quality twee, powerloss minimization and thus security and economic operation of power system

    電力系統無優化對保證電壓質量、降低運行,實現電網的安全經濟運行具重要意義。
  2. As the key block of the wireless communication transmitter in rf, it is very useful in improving the output power and efficiency, lowering the loss of the supply, lowering the size and the weight, lengthening the time of communication. class e power amplifier which is suitable to amplify envelop signal is very important in modern communication system

    率放大器( pa )作為無線通信射頻發射機中不可缺少的關鍵電路,對于提高手機的率效率、降低電源、減小體積重量、延長通話時間著舉足輕重的作用,而適用於恆包絡信號放大的e類率放大器,更是在現代通信系統中佔十分重要的地位。
  3. To prepare international standards for electrical energy measuring and electrical load control equipment ( such as watt - hour meters, var - hour meters, maximum demand indicators, telemetering for consumption and demand, equipment for remote meter reading, time switches, equipment for the control of loads and tarifs and consumer services ) including the equivalent electronic forms of these devices and their accessories

    負責制定電能測量和負荷控制設備(如:、無電度表、最大需量指示器、和需量的遙測、遠程抄表設備、時間開關、負荷和費率控制設備及用戶服務等)的國際標準,包括能相近的運用電子技術實現的設備及其附件。
  4. Abstract : igct is a kind of new ideal medium - voltage and high power semiconductor switching device. it has the advantages of high voltage, high current, low conducting loss, high switching frequency and easy sevies connection. therefore it is suitable for medium - voltage inverters with wide application prospects in the mine

    文摘: igct是一種新的理想的中壓大率半導體開關器件,它具高電壓、大電流、低導通、高開關頻率、易於串聯優點,因此適用於中壓變頻,在煤礦具廣泛的應用前景。
  5. Taking load uncertainties, infeasibility problem and multiple objection of the reactive power optimization in the radial distribution system into consideration, loads are modeled as fuzzy interval numbers. fuzzy power flow is proposed based on fuzzy interval load for the more practical membership function of line losses rate and maximal voltages offset. this thesis presents multiple objection model of the reactive power optimization considering uncertainties using the fuzzy set theory

    對配電網電壓無優化問題中負荷的非概率性的不確定性問題、多目標問題、約束不可行性問題進行了研究,用模糊區間來描述實際的負荷情況,並用負荷的模糊區間值計算配電網的潮流,得到和電壓的模糊區間值,使網率和節點電壓最大偏移量的隸屬函數更接近實際情況;將改進遺傳演算法與模糊集理論相結合,通過求解多目標函數和約束條件的模糊集合的交集,得出網率和節點電壓最大偏移量最小的最優運行狀態。
  6. Using the dynamic mechanical analyzer ( dma ), pdms / pma ipn was investigated at temperature of 5 - 180 c. the initiator, the component ratio, the type of pdms and the filler effected the damping properties. the result showed that the damping ability varied with the parameter and there was an optimal value. the excellent damping material in the papers was ipn, where tan man was 0. 735, and the damping functional temperature ranged with tan 8 > 0. 3 was 46 c. the micro - morphology and structure of pdms / pma ipn were characterized by two kinds of sem

    高分子阻尼材料的效阻尼能區是在ipn材料的t _ g區間內,而研究常溫條件下的阻尼性能更具重要應用價值,運用動態熱機械分析( dma )儀對ipn阻尼材料進行表徵,在5 180內對其因子( tan )進行研究,發現引發劑和交聯劑的用量、聚硅氧烷的用量和分子量等參數對ipn阻尼性能的影響較大,存在一個合理配比值,當pma與粘度為3300pa ? s的pdms之比(質量比)為1 . 17 : 1 、交聯劑用量為1時, tan最大值為0 . 735 ,大於0 . 3的溫域差達到46 。
  7. At first, modeling of these divvies by rate equations to obtain expressions for threshold and slope efficiency is given. on the case of this theory, the large numbers of literatures and datum are consulted, and the laser is home studied. through rationally selecting and improving the reflector surface, ensuring the beam quality, increasing farthest the absorption path, and improving effective pumping frequency ; through designing the water cooler of yag bar, the volume of laser is half the same internal and international production, and the output power is get to the extremum of the same international production

    並在此基礎上查閱了大量文獻和資料,對該種激光器進行了深入的研究,通過對yag棒直徑的合理選取併合理地改進反射鏡面,從而既保證了光束質量又最大限度的增加了吸收長度,效的提高了泵浦效率;在不影響泵浦的前提下,通過效縮短yag棒的長度減小輸出;對yag棒的水冷系統進行優化結構設計,使激光器體積減小到國外同類產品體積的一半,而輸出率已達到國外同類產品的極限值。
  8. In at power supply system some transformers with special connection mode, such as scott transformer, anti - scott transformer, balance transformer and so on, are usual used. the voltage ratio is one of important parameters of transformer

    採用斯科特變壓器、平衡變壓器等特殊接線方式變壓器作為主變壓器,能效抑制負序電流,減少有功損耗和電壓失,提高牽引機車的過負載能力。
  9. First the paper use the different four network operating condition as the primary given conditions and set the 330 / 220kv transformer tap changer position in the standard position, adding the paralleled capacitor bank sets one by one into the network to change the amount of the input reactive power, thus obtained four sets of the 330kv and 220kv bus voltage and the active and reactive power losses changing curves

    進而研究了在每一確定並聯補償電容器組投入量條件下,隨聯變調壓檔位變化而產生出的一組並聯補償量、母線電壓與的變化曲線。進而選出了隴南電網在四種選定電網運行方式下、有功損耗最小條件下的最優綜合控制組合曲線。
  10. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及電網潮流,總結出了如下規則:隴南電網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償電抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變載調壓分接頭來調節,達到控制網內無潮流分佈合理、各變電站母線電壓在理想的范圍內時電網有功損耗最小,從而也提高了電網安全運行水平及供電質量。
  11. It is built using graphical technology of geographic information system and can be used as the graphical plate for power system software, making the operation and the management of the devices easy and intuitionist, and the analysis of network topology more automatic and accurate. in the aspect of the calculation of loss, this system calculates the loss of the active power and reactive power, forms the result in the database considering the differences of load - curves at every node, and allows the property or queries loss of the devices using graphic interface

    它以地理信息系統( gis )的圖形化技術為基礎,為電力系統軟體架設圖形化平臺,使設備的操作、管理更加直觀,使電力系統的網路拓撲分析程序更加自動化、準確;在線計算方面,考慮了各負荷節點負荷曲線的不同,可以從計算結果中分別統計有功損耗和無,也可以方便的在配網圖上對各種元件進行屬性查詢,查詢等。
  12. They both have the function to reduce the active power losses and improve nodes " voltage level

    這兩者都降低網路有功損耗和提高網路節點電壓的能。
  13. The reactive power optimization of a radial distribution system can efficiently minimize the real power losses and improve voltage level of it, so that the yearly running charge will be reduced and the quality of power energy can be increased

    配電網無優化可以效地降低網路有功損耗,提高系統的電壓合格率,從而降低網路運行費用,提高供電質量。
  14. On the condinary, much reactive capacity loaded would be bad, and net ' s voltage would be higher and its security would be influenced. with the needs of reducing line loss, to study the method of compensating reactive capacity has been an important task in power department

    同理,如果就地投入補償過大,多餘的無就要通過輸配電線路向其他設備或區域輸送,也會造成無有功損耗,使得用戶的電壓偏高,影響到電力網的安全經濟運行。
  15. Capacitors dispatch of distribution system is an efficient method to network loss reduction and voltage improvement in the distribution system operation. it is an important component of distribution automation system ( das ). the thesis mainly discusses reactive optimal control of distribution system

    首先,研究了配電網無優化控制的基本理論,討論了配電網無優化控制對電壓和有功損耗的影響,提出配電饋線電容器優化控制對進一步降低配電網的有功損耗效果顯著。
  16. In order to improve the behavior of transformer protection that is incomplete at present in distinguishing magnetizing inrush current from fault current, the paper puts forward a kind of new principle of transformer differential protection after analyzing the characteristic of magnetizing inrush and active power consume of transformers. this protection uses differential protection based on positive sequence active power as a criterion to discriminate internal faults from magnetizing inrush, and ratio restraint differential current protection as a signal to touch off the protection

    針對當前電力系統中變壓器保護由於勵磁涌流鑒別理論不完善而導致的誤動率相對較高的問題,論文在分析了變壓器勵磁涌流特性和有功損耗的基礎上,提出了用變壓器正序率差動作為區別勵磁涌流和故障電流的判據,並以成熟的比率制動差流保護作為內外部故障判據的變壓器主保護。
  17. Based on the theory of branch complex power, accurate formulas are derived to determine complex loss and flow components in power elements. to overcome the deficiencies of the traditional methods which transmission cost is allocated to users only based on active power flow and the existed using portion definitions which fail to take it into account that the interaction of active and reactive power, a new definition of the using portion of a power element by a particular generator or load is addressed

    針對當前輸電費用只按潮流進行分配,無法計及無潮流交叉影響的缺陷和基於傳統的電路理論無法結合潮流來定義元件使用份額的問題,本文又在復率電源的支路率分量理論基礎之上,基於發電機和負荷的復率在支路上引起的有功損耗分量,給出了發電機和負荷對元件使用份額的新定義。
  18. Thus the reactive compensator can be located in the center of the distributed load in the area and make the best user of the compensator ' s capacity. the distance flowed by the reactive current is efficiently reduced and the active loss of power net goes down. two - stage control model is adopted in the optimized control technique of the system

    該系統採用了測量點與補償點與分開的方式,實現了區域性無負荷監視,使無補償點可以安置在區域性分散負荷的中心部位,最大程度地利用了補償容量,效地縮短了無電流傳輸的距離,降低了電網的有功損耗
  19. Then several popular transmission pricing schemes are investigated. to overcome the deficiencies of the traditional methods using active power share of elements " passing power to judge the extent of use to the device, a new concept regarding share of usage of transmission devices is put forward. the concept is based on loss share but not active power share

    針對當前大多數輸電定價的嵌入成本法採用份額衡量設備使用程度的不足,本文提出採用有功損耗分量來衡量設備利用份額,這樣更多地考慮了電力系統實際運行情況,物理意義明確,因而容易為市場成員接受。
  20. In the power transmission system, reactive capacity and active power is closely related to each other, at feeding power load required active power and reactive capacity. if a mount of reactive capacity could be supplied by far location but no local station, a great deal of reactive capacity and active power would be wasted, and its voltage be descended

    在電力傳輸系統中,無率和率是密切相關的,在輸送電力負荷所需要率的同時必須消一定量的無率,同時輸送無電力也需要消率。如果大量的無電力不能就地供應,靠長途輸運,就會產生較大的無有功損耗及電壓降落。