柱型色譜 的英文怎麼說
中文拼音 [zhùxíngshǎipǔ]
柱型色譜
英文
column chromatography-
Except for types of stationary phase, components of mobile phase and types of detectors, other prescribed conditions under each type, such as internal radius and length of chromatographic column, brand of stationary phase, carrier granularity, flow speed of mobile phase, as well as proportion, column temperature, volume of incoming samples of different components of mixed mobile phase and sensitivity of detector can be appropriately changed to accommodate different chromatographic system and reach requirements for applicable test of the system
各品種項下規定的條件除固定相種類、流動相組成、檢測器類型不得任意改變外,其餘如色譜柱內徑、長度、固定相牌號、載體粒度、流動相流速、混合流動相各組成的比例、柱溫、迸樣量、檢測器的靈敏度等,均可適當改變,以適應具體的色譜系統並達到系統適用性試驗的要求。Imidacloprid and triazophos in mixture were determined simultareously by reverse phase hplc, methanol and acetonitrile and water and glacial acetic acid as mobile phase, c18 column and uv200 detecter
摘要採用c18不銹鋼柱和uv200型檢測器,以甲醇?乙腈?水的混合液為流動相,用反相高效液相色譜法對吡蟲啉?三唑磷復配製劑進行定量分析測定。The factors affecting flow profile were reviewed and commented, including the technique of packing column, the design of column head, the shape of columns, temperature and sample viscosity
綜述了影響制備色譜流型的各種因素,包括裝柱技術、柱頭設計、柱形、溫度、樣品粘度等。Preparation and characterization of zwitterionic monolithic column for capillary electrochromatography
兩性電荷型毛細管電色譜整體柱的制備及性能研究This dissertation consists of four chapters : ( 1 ) foreword ( 2 ) the preparation of high performance electrodialytic membrane suppressor for ion chromatography ( 3 ) the applying of the high performance electrodialytic membrane suppressor for ion chromatography ( 4 ) the introduction to the preparation of pcd - 1 ion chromatography instrument
本論文由四個章節組成: ( 1 )前言, ( 2 )高容量電化學抑制柱的制備, ( 3 )高容量電化學抑制柱的應用, ( 4 ) pcd - 1型離子色譜儀的初步研製。The main products now include analytical and preparative hplc systems ( pumps and uv - vis detectors ), dynamic axis pressure columns, common preparative columns, column packing pump systems and all kinds of hplc fittings
公司的主導產品目前有分析高效液相系統、制備高效液相系統、動態軸向壓縮系統、常規、特型制備色譜柱、裝柱系統以及液相色譜儀的附件、備件等。The variable factors of liquid chromatography are composition and ph value of the mobile phase, same type of chromatographic column but from different manufacturers or different batches, column temperature, sampler and detector temperature, etc
液相色譜法中典型的變動因素有:流動相的組成和ph 、不同廠牌或不同批號的同類型色譜柱、固定相、柱溫、進樣器和檢測器溫度等。Preparation of a new weakly acidic cation exchanger and the evaluation of cations by non - suppressed ion chromatography
新型弱酸性陽離子色譜柱的制備及非抑制型離子色譜法電導檢測Abstract : a semi - analytical method is used to modelling the pract ical 3 - zone simulated moving bed chromatography ( smbc ) process for optimal searc hing. the switch time which is the most important operation parameter of 3 - zone smbc is analyzed based on the nonlinear batch chromatography theory firstly, and then adjusted by the deviation between the output and the expectation. the switch time approaches the optimization very soon by continously searching on the basi s of the theory. the parameters of the practical system are inputted into simulat ion, the result is used in our experiment and a good separation is obtained
文摘:針對三帶模擬移動床色譜的實際模型,用一種融合了前饋與反饋的半解析優化計算方法對三帶模擬移動床色譜過程進行了模擬.首先,由非線性單柱色譜理論解析地給出一個三帶模擬移動床色譜的主要操作參數即切換時間值,然後利用所得結果與目標量之間的偏差來校正切換時間,在理論指導下進行優化搜索,切換時間能很快達到最佳值.將測得的系統參數引入計算,並將計算結果用於實際操作,得到了很好的分離效果Oil of cassia, chinese type. determination of trans - cinnamaldehyde content. gas chromatographic method on capillary columns
中國型肉桂油. trans肉桂醛含量的測定.毛細管柱氣相色譜法Properties of filler ( such as carrier ' s shape, particle diameter, pore size, surface area, as well as surface coverage, carbon content and bonded types of the bonded group ) and filling of chromatographic column shall directly affect retention behavior and separation effect of the articles to be tested
填充劑的性能(如載體的形狀、粒徑、孔徑、表面積、鍵合基團的表面覆蓋度、含碳量和鍵合類型等因素)以及色譜柱的填充,將直接影響待測物的保留行為和分離效果。Sal - gel column is a new - type of chromatographic column with high temperatures tolerance, excellent separation and repeatability
摘要溶膠凝膠柱是一種新型色譜柱,具有耐高溫、分離效果佳、重現性好、製作工藝簡單等特點。分享友人