校準檢測器 的英文怎麼說

中文拼音 [jiàozhǔnjiǎn]
校準檢測器 英文
calibrated detector
  • : 校名詞1. (學校) school 2. (校官) field officer3. (姓氏) a surname
  • : Ⅰ名詞1 (標準) standard; guideline; criterion; norm 2 (目標) aim; target Ⅱ動詞1 (依據; 依照)...
  • : Ⅰ動詞1 (查) check up; inspect; examine 2 (約束; 檢點) restrain oneself; be careful in one s c...
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 檢測器 : detector
  • 檢測 : check; detection; test; gauging; detecting; sensing; [工業] checkout; measuring
  1. The influential factor of accuracy of measured pulp beating degree, including water temperature, pulp consistency, checking instrument and so on is discussed, and one convenient way of measuring pulp consistency is introduced

    摘要初步探索影響漿確性的幾個因素,包括水溫、漿濃度、儀等,並介紹了一種簡單易行的濃度方法。
  2. Calibrators for near headlamp tester of motor vehicle

    機動車近光
  3. The principle and the mechanical structure of the air - gap inductance - type transducer are analyzed in this article, and the static parameters are calibrated. dynamic calibration is applied to air - gap inductance - type transducer which is not good in dynamic capability, to obtain the dynamic parameters of the transducer and its measuring circuit. based on the result of the dynamic calibration, the transducer and its serving circuit are modeled so that the method of how to improve the dynamic performance can be found

    本文對現有氣隙式電感傳感在原理和機械結構上作了深入的分析,對其參數進行了靜態標定;並且針對常規電感傳感動態響應低,不宜用於快速動態量的缺點,引入試系統動力學的思想,設計了一套動態系統,對現有傳感進行多次動態,根據動態的實驗結果對現有傳感建立數學模型,得到現有傳感的動態特性;在此基礎上,根據磨床工件在線的要求,設計一個硬體補償系統來提高整個試系統的動態特性。
  4. Verification regulation of headlamp for vehicle tester ' s aligner

    汽車前照燈試行
  5. Verification regulation of calibrators for headlamp tester of motor vehicle

    機動車前照燈定規程
  6. Sb2015 - 3 precision decade dc resistance box adopts high voltage glass glaze resistors and special high voltage seal switch. its electric performance is very stable and insulation intension is very high. the resistance value can be adjusted under the condition of ceaselessly opening voltage ( note : the using switch should not be at the point of 0. ) it is easy to operate and suitable to be used to calibrate insulation resistance meter, and suitable to be used as high resistance standard

    3型精密十進位直流電阻箱採用高壓玻璃釉電阻及獨特的高壓密封開關,電性能穩定可靠、絕緣強度高、可在不斷開試電壓的條件下調節電阻值(正在使用的那隻開關不處在「 0 」位置時) 、操作方便,適用於定/絕緣電阻表,也可作為高阻標
  7. Sb2015 - 2 precision decade dc resistance box adopts high resistance superfine glass silk and special high voltage seal switch. it electric performance is very stable and insulation intension is very high. the resistance value can be adjusted under the condition of ceaselessly opening voltage ( note : the using switch should not be at the point of 0. ) it is easy to operate and suitable to be used as dc resistance standard to calibrate insulation resistance meter

    2型精密十進位直流電阻箱採用高阻玻璃微細絲電阻及獨特的高壓密封開關,電性能穩定可靠、絕緣強度高、可在不斷開試電壓的條件下調節電阻值(正在使用的那隻開關不處在「 0 」位置時) 、操作方便,適用於定/絕緣電阻表,也可作為直流電阻標
  8. A resolution method in software is applied to calibrate zero point and full scale of the circuit. software approach to nonlinear correction for sensor and circuit is presented. therefore system error is eliminated, and measurement accuracy of temperature is improved. the signal of acidity electrode is detected by a differential amplifier circuit, which consists of operational amplifiers tlc2254 with high input impedance and low drift

    採用橋路和單運放差動放大電路對溫度傳感信號放大,軟體正溫度傳感量電路的非線性,軟體量電路的零點和滿度,消除量電路的系統誤差,提高補償溫度的量精度;採用高阻、低漂移運放tlc2254組成高阻差動放大電路用於酸度電極信號量。
  9. The calibration device is a requisite device which is used for checking and ensuring the quality of the electrical quantity transducer

    電量變送裝置是定期對電量變送進行計量定,確保電量變送質量必不可少的
  10. 7. based on our crsi and algorithm and double lcslm, an adaptive optical hardware system which c & n be used to model arbitrary complicated wavefront and the compensation of the wavefront can be accomplished was built. and according to the characteristic of a crs interferogram of a step wavefront produced by an lctv, the pixel - level calibration of this system is implemented

    七、採用已建立的空間相位調制環路徑向剪切干涉儀及其波前重建演算法,和位相調制持性已知的兩塊液晶空間光調制,創建了一套用於模擬產生任意畸變波前並加以和反饋控制的自適應光學硬體系統,並通過臺階波前對該系統實現了像素級
  11. Calibration specification for construction quality tester sets

    建築工程質量規范
  12. That test part of the software is primarily used to complete the test of some parameters, such as time base, time - expand, time interval, voltage interval, vertical, stable state, transient state and scanning linearity. the result of the test needs to be analyzed and judged. clear user interface and timely warnings for mistakes of testing process inside because of the user ' s fault operating make whole test process more easier than it did on a time

    該軟體的試部分主要用於完成對示波掃描時間系數、擴展掃描時間系數、 t時間量、 v電壓量、垂直偏轉系數、頻帶寬度、信號、脈沖瞬態響應、掃描線性誤差時等參數的定任務,並對試結果進行及時的分析和判斷,由於界面清晰,而且對試過程中由於用戶的誤操作都有及時的錯誤提示,使得整個試過程簡單易行,對于用戶來講掌握起來也更為方便些。
  13. The study of this paper indicates that, the combined binarization method can keep details well and tolerate the abominable state ; the method to estimate skew angle based on radon transformation is very exact, and the distortion of corrected image is also very little ; the vlp location method based on wavelet analysis and intensity moment has a high location exactness and a soon processing time ; and intelligent character recognition machine can accomplish the function of self - adaption, self - correction, self - study, etc

    本文研究表明:混合二值化方法能較好的保留圖像細節,抗噪聲能力強;基於radon變換估計傾斜角度的方法角度精確,正後圖像失真較小;基於小波分析和亮度矩的車牌定位方法定位確率高,速度快;仿人智能字元識別則能實現識別字元過程中的自適應、自正、自學習功能等。
  14. This thesis elaborates a self - developed measuring equipment for pulse oximetry. this unit can output the standard oximetry test signal comparatively with difference sensors of the tested pulse oximetry, include pulse rate, peep and oxygen saturation

    所述脈搏血氧儀裝置,它能產生一個與被脈搏血氧儀傳感類型相對應的標血氧試信號,包括脈率、脈沖幅度和血氧飽和度。
  15. The following is the result : for calibration set, correlation coefficient r = 0. 84, coefficient of variation is 5. 45 % ; for prediction set, correlation coefficient r = 0. 93, coefficient of variation is 5. 54 %. the analysis of experiment ' s result shows that this apparatus can fulfill the application of practice using

    對實驗結果分析,集中預值與化學值相關系數r = 0 . 84 ,變異系數為5 . 45 ,驗集中預值與化學值的相關系數r = 0 . 93 ,變異系數為5 . 54 ,表明本儀可以滿足實際應用的需要。
  16. A measuring system for calibrators of headlamp tester for motor vehicle using planar array ccd as detector is introduced in the paper

    本文介紹了一種採用面陣ccd成像技術作為試方法的汽車前照燈儀遠近光定系統。
  17. The lighting and light matching capability of the automobile headlamp is very important to the safety of night - driving. the measurement of automobile headlamp must use the headlamp measure instrument, which is needed to use a calibration instrument to calibrate. however, whether the calibration instrument is standard must be checked up by a measure system

    汽車前照燈的需要用「汽車前照燈儀」 ,而「汽車前照燈儀」的定期工作需要用「前照燈」來進行; 「前照燈」是否合乎標需要靠「前照燈定系統」來
  18. Standard practices for calibration of ozone monitors using transfer standards

    使用傳送標對臭氧
  19. For the same examination / calibration, two examination / calibration persons have to be required who are qualified through training ( for standard examination devices, who should be qualified measurers through training )

    對同一定/,必須具備二個經培訓合格的定/人員(對標具,應為經培訓合格的計量員) 。
  20. Examination / calibration specifications have to be required ; for standard examination devices, the uniform national standards have to be carried out

    必須具備定/規程,對標具,必須執行國家統一的標
分享友人