正時閥 的英文怎麼說

中文拼音 [zhēngshí]
正時閥 英文
timing valve
  • : 正名詞(正月) the first month of the lunar year; the first moon
  • : shí]Ⅰ名1 (比較長的一段時間)time; times; days:當時at that time; in those days; 古時 ancient tim...
  • : 名詞1 (指在某方面有支配勢力的人物或家族) established house or power group; a powerful person or...
  1. Install a minimum of 1 " above flood level of fixture if factory deck mounted or not less than 6 " if general plumbing field application

    安裝要使蓋側面朝上,要便於測試和維修。不要安裝在隱蔽的位置或區域,在這些地方,由於內件常磨損產生的水泄漏可能導致門損壞。
  2. Tvv thermal vacuum valve

    水溫傳感控制真空點火正時閥
  3. Accordingly, using graph theory and operating experience abroad for reference, it firstly brings forward a new method of voltage rectification which based on pilot bus with voltage control area in view of the weak coupling among every vca ( voltage control area ), using decomposing method of multi critical value, it realizes the eliminating vinculum of every vca. and then, the rectification starts by pilot bus voltage of every vca. so the resolution of whole power net is diverted into calculating smaller sub - net

    由於各個電壓控制區之間無功電壓的弱耦合性,利用多值分解的分區演算法,實現區域間的解耦,然後根據各個子網路的主導節點的電壓進行校,從而把求解整個網路的問題轉化為求解各個小的子網路,降低了網路維數,減少了無功設備控制動作次數,提高了校成功率,縮短了計算間。
  4. When the water is full, the bwf should be stopped immediately, then to weak firing and open blowdown and drain valves till the water level returns to normal

    滿水后應減少給水或及排水,立即停止鍋爐給水,並減弱燃燒,開啟排污及流水,直到水位恢復常后才關閉。
  5. Through analyzing the figure of energy wasting of pump, the quality in pipes is direct proportion of the speed of pump if the speed of pump is reduced. the power of electromotor fell the cube of the speed of pump. so the energy wasting of constant pressure water supply based on variable frequency speed regulating technology is envident less than the traditional mode is used throttle to supply water

    分析水泵工況的能耗比較圖,可以看出利用變頻調速實現恆壓供水,當轉速降低,流量與轉速成比,功率以轉速的三次方下降,與傳統供水方式中用門節流方式相比,在一定程度上可以減少能量損耗,能夠明顯節能。
  6. Currently, the degrees of valves only need fine - tuning in the sites in order that the flux in the duct can be regulated to the design range

    現場調試,在常情況下,只需微調各種風的開度,即可使各管段的實際流量調至設計范圍之內。
  7. Pay attention to the flow direction of medium and install the valve referring to the indicating arrow on the valve body

    安裝請認清介質流向並按體上指示箭頭方位確安裝。
  8. Xh rubber slowly - closing cut - off vavle is a new water supply and drainage vavle with full rubber structure, duck - mouthed appearance and functions or positive flow - in and reserve cut - off. according to thrust analysis and calculation as well as different operation mechanism and different rubber products by special processing. all will be open at weak hydraulic pressure is higher, the vavle gate will open more greatly and the water flow is greater. at reserve operation, the vavle gate closes naturally and seals tightly cut - off vavle ; the back pressure is higher, the vavle gate closes more tightly and the seal effect is better. it is used widely in various drainage exit to prevent from pouring backwards and flowing backwards in city planning, water conservancy and sewage disposal etc. it is the ideal productto replace flap vavle

    Xf型橡膠緩閉逆止是一種全橡膠結構外形呈「鴨嘴狀」 ,具有「向流入反向逆止」功能的新型給排水門產品。它根據受力分析和受力計算,針對不同的工況,採用不同的設計機理,選用不同的橡膠配方,並按特殊工藝製作而成。向工作,水由進水口流入,微小的水壓,便能打開門,水壓越大,門開啟越大,水流量越大。
  9. When it is too cold or there is not enough thermal energy in the first - nst so we can not regulate to the initial value even if the valves are all opened, we must at this time revise initial value of the t6mpeate of the second - net, lower the heat - supply standard, and make the pots which near the heat - source or far to the heatsource are both have energy to.,

    當天氣太冷或一次熱網供熱能力不足,即便是二次熱網門全開也不能調節到設定值,此必須修二次熱網溫度設定值,降低供熱標準,使熱源近端和末端都有熱量可供,解決系統失調。
  10. The ids works by two way, misuse detection and anomaly detection, misuse detection flags an intrusion on intrusion signature, this kind of detecting technic can be realized much more easily, and much more accurate, but it can not find some intrusiones that have been disguised or new kinds of intrusion. the anomaly detection can detect in more wide field, anomaly detection can compare new statistic data with average record, then anomaly record will be found, but it ' s more difficult to set a threshold, if the threshold is too big, some intrusion may be put through, if the threshold is too small, the ids will give more false positive alarm, and the threshold will be different with different people or different period, so the ids just simply show us their suspicious record, the administrator or expert will be in duty to analyze this record and give conclusion, the ids give more alarm than it should, leave us more detection record to analyze, and this is a hard work, we can not distinguish an intrusion or not if we analyze only one record, but we can judge if we find the relation among mass detection evidence. in this article, we try distinguish an intrusion using d - s theory ( proof theory ) instead using manual work, the ids will be more helpful and efficient

    濫用檢測採用的是特徵檢測的方法,實現較為簡單,判斷的準確性較高,但是不能判斷一些經過偽裝的入侵或特徵庫中尚未包含的入侵,異常檢測能夠根據以往記錄的特徵平均值,判斷出異常情況,但是對于異常到什麼程度才視為入侵,這個值非常難以確定,值設定的太高,有可能漏過真的入侵,如果設定的值太低,又會產生較高的誤警率,而且這個值因人而異,因而異,因此現在的入侵檢測系統把這部分異常記錄以一定的形式顯示出來或通知管理人員,交給管理人員去判斷,而這些ids系統難以判斷的記錄,如果對每個證據單獨地進行觀察,可能是難以判斷是否是入侵,而把許多先後證據關聯起來,專家或管理人員根據經驗能夠判斷訪問的合法性,本文試圖引入人工智慧中證據理論的推理策略和示例學習方法,代替人工檢查分析,可以提高效率,降低誤警率,並可以對一個在進行得可疑訪問實現實檢測,通過搜索及判斷,及阻斷非法訪問,比事後得人工處理更有意義。
  11. When install, first the two ellipse oval flange on positive - negative pressure measuring container of transmitter would be take off, then take three valve units install on transmitter, turn tighten four screws, final take ellipse oval flange solidly install on three valve units

    安裝選將變送器負壓測量容室上的兩只橢圓形法蘭取下,然後將三組安裝于在變送器上,旋緊四個螺釘,最後將橢圓形法蘭牢固安裝在三組上。
  12. At this time, slowly open the test ball valve completely, then a lot of water is discharged at the drainage outlet, close the test ball valve, the drainage device closes too, this shows that action of anti - pollution isolating valve is normal

    緩慢將試驗球完全打開,這排污口有大量水排出,關閉試驗球,排污器也隨之關閉,這說明防污隔斷動作常。
  13. In order to size a stop - check the technical information needed is saturated steam gage pressure in pounds per square inch and actual required steam volume flow in pounds per hour

    為了確定確的截止止回的通徑,需要下列有關的技術參數,飽和蒸汽表壓(磅/平方英寸) ,和實際所需的氣流量(磅/小) 。
  14. Therefore, if both check valves foul, and simultaneous negative supply and positive backpressure develops, the relief valve uses the air - in / water - out principle to stop potential backflow

    因此,如果兩個止回都受到污染,並且同出現負供應壓力和反壓力,則這種安全就利用氣進/水出原理來阻止潛在的迴流。
  15. What system interruption thresholds need to be established when you develop performance metrics to indicate the impact of thresholds on uptime availability

    在您開發性能表來指示值對常運行間的可用性的影響,該建立什麼系統斷值呢?
  16. Vtc valve timing control

    氣門控制電磁
  17. First of all, some improvements have been carried out on the test equipment in order to void the singularities when the magnetic force is tested

    首先,為了克服電磁測試裝置在對電磁力進行測量容易出現的不常現象,對測力裝置進行了改進設計。
  18. The valve remains open while the operating pressure is within the normal operating limits

    當操作壓力維持在常工作界限內保持開的狀態。
  19. Scv spark control valve

    點火調整
  20. Live - loading automatically compensates for the transient loads which cause bonnet movement by maintaining a positive load on the pressure seal gasket as the pressure reduces

    動負載自動補償波動轉換中的變化,在壓力減少帽會產生運動,維持壓力密封墊圈上的向負載。
分享友人